2400465 CABLE AS Caterpillar parts
3306B, 3406C, 3408C, 3412, 3456, C15, C15 I6, C18, C18 I6, C9
Rating:
Alternative (cross code) number:
CA2400465
240-0465
2400465
CA2400465
240-0465
2400465
Weight: 1 pounds 0 kg.
GENERATOR SET, POWER MODULE,
Compatible equipment models: 2400465:
Information:
Single UPS
Illustration 1 g02143224
(3) Slot for the relay communications card (4) Open slots for the optional communication cards. (6) Screw-type terminal block used for connecting the contacts and the coils of the two external battery circuit breakers "XMB07" and "XMB08" (7) Screw-type terminal block used for the connection of the remote emergency power off "REPO" "XMB06".
Ensure sufficient isolation of power, control, and communication cables. Run the communication cables separately from the power cables. Reinforce the insulation of the control and communication cables if any risk of contact with the power cables exists. Running the cables together may cause unintentional contact with live power cables resulting in serious personal injury or death.
Separate the control and communication cables from the power cables.
Route the cables together in front of the protection panels.
Using cable straps, secure the cables to the panels as indicated by the arrows in Illustration 1 .
Table 1
Description of the Cable     Insulation Level     Callout (1)    
Relay Communication Card     SELV     3    
Optional Communication Card     SELV or LV     4    
Circuit Breaker Cables for the External Battery     SELV     6    
General Shutdown Cable     SELV     7    
( 1 ) Refer to Illustration 1.Parallel UPS
Illustration 2 g02143228
(1) Connectors for auxiliary interconnections of parallel UPS units (INTN PCA), optional (3) Slot for the relay communications card (4) Free slots for the optional communication cards. (6) Screw-type terminal block used for connecting the contacts and the coils of the two external battery circuit breakers "XMB07", "XMB08" (7) Screw-type terminal block used for the connection of the remote emergency power off "REPO" "XMB06".
Ensure sufficient isolation of power, control, and communication cables. Run the communication cables separately from the power cables. Reinforce the insulation of the control and communication cables if any risk of contact with the power cables exists. Running the cables together may cause unintentional contact with live power cables resulting in serious personal injury or death.
Separate the control and communication cables from the power cables.
Route the cables together in front of the protection panels.
By using cable straps, secure the cables to the panels as indicated by the arrows in Illustration 2.
Table 2
Cable description    Insulation level    Callout (1)    
External bypass cabinet cable     ELV     1    
CAN cables     SELV     1    
Exchange-current cables     SELV     1    
Relay communication card     SELV     3    
Optional communication card     SELV or LV     4    
External battery circuit-breaker cables     SELV     6    
General-shutdown cable     SELV     7    
( 1 ) Refer to Illustration 2.
Illustration 1 g02143224
(3) Slot for the relay communications card (4) Open slots for the optional communication cards. (6) Screw-type terminal block used for connecting the contacts and the coils of the two external battery circuit breakers "XMB07" and "XMB08" (7) Screw-type terminal block used for the connection of the remote emergency power off "REPO" "XMB06".
Ensure sufficient isolation of power, control, and communication cables. Run the communication cables separately from the power cables. Reinforce the insulation of the control and communication cables if any risk of contact with the power cables exists. Running the cables together may cause unintentional contact with live power cables resulting in serious personal injury or death.
Separate the control and communication cables from the power cables.
Route the cables together in front of the protection panels.
Using cable straps, secure the cables to the panels as indicated by the arrows in Illustration 1 .
Table 1
Description of the Cable     Insulation Level     Callout (1)    
Relay Communication Card     SELV     3    
Optional Communication Card     SELV or LV     4    
Circuit Breaker Cables for the External Battery     SELV     6    
General Shutdown Cable     SELV     7    
( 1 ) Refer to Illustration 1.Parallel UPS
Illustration 2 g02143228
(1) Connectors for auxiliary interconnections of parallel UPS units (INTN PCA), optional (3) Slot for the relay communications card (4) Free slots for the optional communication cards. (6) Screw-type terminal block used for connecting the contacts and the coils of the two external battery circuit breakers "XMB07", "XMB08" (7) Screw-type terminal block used for the connection of the remote emergency power off "REPO" "XMB06".
Ensure sufficient isolation of power, control, and communication cables. Run the communication cables separately from the power cables. Reinforce the insulation of the control and communication cables if any risk of contact with the power cables exists. Running the cables together may cause unintentional contact with live power cables resulting in serious personal injury or death.
Separate the control and communication cables from the power cables.
Route the cables together in front of the protection panels.
By using cable straps, secure the cables to the panels as indicated by the arrows in Illustration 2.
Table 2
Cable description    Insulation level    Callout (1)    
External bypass cabinet cable     ELV     1    
CAN cables     SELV     1    
Exchange-current cables     SELV     1    
Relay communication card     SELV     3    
Optional communication card     SELV or LV     4    
External battery circuit-breaker cables     SELV     6    
General-shutdown cable     SELV     7    
( 1 ) Refer to Illustration 2.
Cat SIS web machinery list:
Parts cable Caterpillar catalog:
1598050
CABLE
1090, 1190, 1190T, 120K, 120K 2, 120M, 120M 2, 1290T, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16H, 16M, 21...
1090, 1190, 1190T, 120K, 120K 2, 120M, 120M 2, 1290T, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16H, 16M, 21...
4419600
CABLE AS
C15 I6, C18 I6
C15 I6, C18 I6
4419601
CABLE AS
C15 I6, C18 I6, C9
C15 I6, C18 I6, C9
4431876
CABLE AS
C15 I6, C18 I6, C9
C15 I6, C18 I6, C9
4574123
CABLE AS
C15
C15
4370497
CABLE
C15
C15
1690300
CABLE AS
3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C27, C32, G3406, G3412, PMG3516
3412C, 3456, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C27, C32, G3406, G3412, PMG3516
2045588
CABLE
3608
3608
1777222
CABLE
3608
3608
1311432
CABLE
3608, 3616
3608, 3616
1311431
CABLE
3512B, 3606, 3608, 3612, 3616, G3508
3512B, 3606, 3608, 3612, 3616, G3508
1311429
CABLE
3606, 3608, 3612, 3616, C280-12, C280-16, C280-6, C280-8, G3508, G3612, G3616
3606, 3608, 3612, 3616, C280-12, C280-16, C280-6, C280-8, G3508, G3612, G3616
2886114
CABLE AS
C4.4
C4.4
2914868
CABLE AS
C4.4, C6.6
C4.4, C6.6
2665351
CABLE AS
C4.4
C4.4
2873230
CABLE AS-BATTERY
3512B
3512B
2873229
CABLE AS-BATTERY
3512B
3512B
8C3055
CABLE
5130B, 525B, 535B, 950F II, 950G, 960F, 994, C7