TECHNICAL INFORMATION BULLETIN May 08, 2002
Generators SR4B (2DN1-1562, 2ED1-1770,
2FN1-1584, 2HN1-610, 2SN1-
701, 3FN1-1122, 5SN1-745,
5VA1-820, 5YA1-1201, 5ZA1-
775, 6DW1-1269, 6LA1-874,
6SA1-2391, 8FD1-749, 8NN1-
1034, 8XS1-522, 8ZD1-890,
9CN1-590, AAD1-502
Component Code: 1404SUBJECT: 5kV Class Droop Current Transformer (CT) that Is Installed on Certain SR4B Generators May Not Operate as Designed
PROBLEM:
The factory-installed droop CT's on certain 2400 volt through 4160 volt (medium voltage) SR4B generators may be marginal in VA size. SR4B generators that are marginal in VA size may begin to saturate at full generator load or may begin to saturate at near-full generator load. Caterpillar voltage regulator (VR) droop circuits that are used on SR4B generators utilize a 5 ampere secondary CT output that is converted to 5 volts across the 1 ohm droop resistor. This may result in the following:
An inaccurate reactive VAR when paralleling multiple generators
An imprecise PF (or VAR) stability when paralled to a utility source
SOLUTION:
Caterpillar has redesigned the droop circuit and removed the 123-6046 Resistor. In the medium-voltage SR4B generators, the 123-6046 Resistor has been replaced with a 204-3544 Current Transformer. The 5 kV CT's remain the same. The 204-3544 Current Transformer is mounted on the existing generator terminal DIN rail and is wired as follows:
Output wire 5 from the droop CT connects to the 204-3544 Current Transformer input terminal H1
Output wire 6 from the droop CT connects to the 204-3544 Current Transformer input terminal H2
Transformer output terminal X1 is wired to the existing generator terminal 5
Transformer output terminal X2 is wired to the existing generator terminal 6
From this point, the VR droop circuit wiring remains unchanged. The VR3 utilizes a 197-3531 Rheostat. The DVR and the VR6B are connected direct. See Illustration 1 for wiring details.
A parts kit (218-4827) will be available for the field retrofit for the 3500 product. The parts kit will include all of the components necessary to make the change-over as described above.
Utilization and set-up for reactive droop paralleling between generators is not affected by this change. Observe standard recommended proactices for proper cross-current compensation (CCC) wiring between the CT's. This change also does not affect the CCC operation.
Illustration 1. Wiring Diagram
COPYRIGHT 2002 CATERPILLAR
ALL RIGHTS RESERVED
Caterpillar parts catalog:
Parts cable Caterpillar catalog:
5P0747
CABLE
205B, 206B, 211B, 212B, 215, 215B, 215C, 215D, 216, 225, 225D, 229, 229D, 231D, 235, 235B, 235C, 235D, 236B, 245, 245B, 245D, 267B, 268B, 30/30, 301.5, 302.5, 303, 304, 304.5, 305, 305.5, 307D, 308D, ...
205B, 206B, 211B, 212B, 215, 215B, 215C, 215D, 216, 225, 225D, 229, 229D, 231D, 235, 235B, 235C, 235D, 236B, 245, 245B, 245D, 267B, 268B, 30/30, 301.5, 302.5, 303, 304, 304.5, 305, 305.5, 307D, 308D, ...
5P0761
CABLE
1090, 1190, 1190T, 120B, 120G, 120H, 120H ES, 120H NA, 1290T, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H, 1...
1090, 1190, 1190T, 120B, 120G, 120H, 120H ES, 120H NA, 1290T, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H, 1...
8C3056
CABLE
1090, 1190, 1190T, 120K, 120K 2, 1290T, 12K, 1390, 140K, 140K 2, 160K, 2290, 2384C, 2390, 2391, 2470C, 2484C, 2491, 2570C, 2590, 2670C, 2864C, 323D2 L, 325B L, 325C, 325D MH, 330B L, 330C MH, 330D MH,...
1090, 1190, 1190T, 120K, 120K 2, 1290T, 12K, 1390, 140K, 140K 2, 160K, 2290, 2384C, 2390, 2391, 2470C, 2484C, 2491, 2570C, 2590, 2670C, 2864C, 323D2 L, 325B L, 325C, 325D MH, 330B L, 330C MH, 330D MH,...
9U8746
CABLE AS-COAXIAL
1090, 1190, 1190T, 1290T, 1390, 2290, 236D, 2390, 2391, 242D, 246C, 246D, 2491, 256C, 257D, 2590, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D...
1090, 1190, 1190T, 1290T, 1390, 2290, 236D, 2390, 2391, 242D, 246C, 246D, 2491, 256C, 257D, 2590, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D...
1536271
CABLE AS
303, 953C, 963C, 973C, AD30, AD45, AD45B, AD55, AD55B, AD60, D3G, D4G, D5G
303, 953C, 963C, 973C, AD30, AD45, AD45B, AD55, AD55B, AD60, D3G, D4G, D5G
5G3518
CABLE GP
933, 933C, 939, 939C, D3B, D3C, D3C III, D3G, D4C III, D4G, D5C III, D5G
933, 933C, 939, 939C, D3B, D3C, D3C III, D3G, D4C III, D4G, D5C III, D5G
9C6601
CABLE AS
517, 527, 933C, 939C, D3C III, D3G, D4C III, D4G, D5C III, D5G
517, 527, 933C, 939C, D3C III, D3G, D4C III, D4G, D5C III, D5G
1808709
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
1808710
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
1808711
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
1808717
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
1874489
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
3114863
CABLE AS-COILED
D3G, D3K XL, D4G, D4K XL, D5G, D5K LGP, D6K LGP, D6N, D6T
D3G, D3K XL, D4G, D4K XL, D5G, D5K LGP, D6K LGP, D6N, D6T
1808714
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
1808713
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
1874489
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
1808717
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
1808711
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
1704068
CABLE AS
572R II, 904B, D7R II, D7R XR
572R II, 904B, D7R II, D7R XR
1671882
CABLE AS
572R II, D7R II
572R II, D7R II
1671880
CABLE AS
572R II, D7R II
572R II, D7R II
2671793
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G
2762263
CABLE AS-GOVERNOR CONTROL
D3G, D4G, D5G
D3G, D4G, D5G
2237764
CABLE AS
D3G, D4G, D5G
D3G, D4G, D5G