3194235 CABLE GP-GOVERNOR CONTROL Caterpillar parts
321C
Rating:
Alternative (cross code) number:
CA3194235
319-4235
3194235
CA3194235
319-4235
3194235
EXCAVATOR,
Compatible equipment models: 3194235:
Information:
Automation Operations Area
When Barrier Control Panel (BCP) isolation switch (6) is moved to the ON position, 24V is supplied to the following components.
AIS LADAR (4A) light curtain (4B) , and gate proximity switch (4C) (Personnel barrier)
BCP reset switch (5)
BCP shutdown switch (7)
Lanyard switch (Machine barrier) (10)AIS LADAR (4A) light curtain (4B) , and gate proximity switch (4C) (Personnel barrier) is supplied 24V from BCP digital input module (21). When personnel barrier (LADAR, light curtain or gate) (4) is active, 24V is returned to BCP digital input module (21). BCP digital input module (21) status indicator "5" (29) and status indicator "13" (33) will illuminate. BCP shutdown interface module (20) sends the status of AIS LADAR (4A), light curtain (4B) , or gate proximity switch (4C) to AIS PLC (11) via the LARN and AOS Ethernet network.BCP reset switch (5) is supplied 24V from BCP digital input module (21). When BCP reset switch (5) is depressed, 24V is returned to BCP digital input module (21). BCP digital input module (21) status indicator "7" (28) will illuminate. BCP shutdown interface module (20) sends the status of BCP reset switch (5) to AIS PLC (11) via the LARN and AOS Ethernet network.BCP shutdown switch (7) is supplied 24V from BCP digital input module (21). When BCP shutdown switch (7) is moved to the RELEASED position, 24V is returned to BCP digital input module (21). BCP digital input module (21) status indicator "1" (27) and status indicator "9" (31) will illuminate. BCP shutdown interface module (20) sends the status of BCP shutdown switch (7) to AIS PLC (11) via the LARN and AOS Ethernet network.Lanyard switch (Machine barrier) (10) is supplied 24V from BCP digital input module (21). When lanyard switch (Machine barrier) (10) is in the SET position, 24V is returned to BCP digital input module (21). BCP digital input module (21) status indicator "3" (26) and status indicator "11" (30) will illuminate. BCP shutdown interface module (20) sends the status of lanyard switch (Machine barrier) (10) to AIS PLC (11) via the LARN and AOS Ethernet network.Barrier Control Panel (BCP) (1) status is now set to active on AIS PLC (11).When all BCP (1) in the AIS area are active, AIS PLC (11) will set the AIS area to armed. AIS PLC (11) sends the area arm message to all BCP (1) in the AIS area.When BCP (1) receives the area arm message, BCP shutdown interface module (20) energizes expander relay (23), AIS warning light (2), and start relay (24).The following will now occur.
24V is supplied to AIS warning light (2) indicating the operations area is armed. BCP digital output module (22) status indicator "9" (36) will illuminate.
Expander relay (23) closes contacts, completing the enable circuit from Machine Shutdown Module (MSM) (9). BCP digital output module (22) status indicator "1" (34) will illuminate. BCP digital input module (21) status indicator "15" (32) will turn off.
Start relay (24) supplies a 24V signal to MSM (9). BCP digital output module (22) status
When Barrier Control Panel (BCP) isolation switch (6) is moved to the ON position, 24V is supplied to the following components.
AIS LADAR (4A) light curtain (4B) , and gate proximity switch (4C) (Personnel barrier)
BCP reset switch (5)
BCP shutdown switch (7)
Lanyard switch (Machine barrier) (10)AIS LADAR (4A) light curtain (4B) , and gate proximity switch (4C) (Personnel barrier) is supplied 24V from BCP digital input module (21). When personnel barrier (LADAR, light curtain or gate) (4) is active, 24V is returned to BCP digital input module (21). BCP digital input module (21) status indicator "5" (29) and status indicator "13" (33) will illuminate. BCP shutdown interface module (20) sends the status of AIS LADAR (4A), light curtain (4B) , or gate proximity switch (4C) to AIS PLC (11) via the LARN and AOS Ethernet network.BCP reset switch (5) is supplied 24V from BCP digital input module (21). When BCP reset switch (5) is depressed, 24V is returned to BCP digital input module (21). BCP digital input module (21) status indicator "7" (28) will illuminate. BCP shutdown interface module (20) sends the status of BCP reset switch (5) to AIS PLC (11) via the LARN and AOS Ethernet network.BCP shutdown switch (7) is supplied 24V from BCP digital input module (21). When BCP shutdown switch (7) is moved to the RELEASED position, 24V is returned to BCP digital input module (21). BCP digital input module (21) status indicator "1" (27) and status indicator "9" (31) will illuminate. BCP shutdown interface module (20) sends the status of BCP shutdown switch (7) to AIS PLC (11) via the LARN and AOS Ethernet network.Lanyard switch (Machine barrier) (10) is supplied 24V from BCP digital input module (21). When lanyard switch (Machine barrier) (10) is in the SET position, 24V is returned to BCP digital input module (21). BCP digital input module (21) status indicator "3" (26) and status indicator "11" (30) will illuminate. BCP shutdown interface module (20) sends the status of lanyard switch (Machine barrier) (10) to AIS PLC (11) via the LARN and AOS Ethernet network.Barrier Control Panel (BCP) (1) status is now set to active on AIS PLC (11).When all BCP (1) in the AIS area are active, AIS PLC (11) will set the AIS area to armed. AIS PLC (11) sends the area arm message to all BCP (1) in the AIS area.When BCP (1) receives the area arm message, BCP shutdown interface module (20) energizes expander relay (23), AIS warning light (2), and start relay (24).The following will now occur.
24V is supplied to AIS warning light (2) indicating the operations area is armed. BCP digital output module (22) status indicator "9" (36) will illuminate.
Expander relay (23) closes contacts, completing the enable circuit from Machine Shutdown Module (MSM) (9). BCP digital output module (22) status indicator "1" (34) will illuminate. BCP digital input module (21) status indicator "15" (32) will turn off.
Start relay (24) supplies a 24V signal to MSM (9). BCP digital output module (22) status
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts cable Caterpillar catalog:
1706929
CABLE AS
311C, 311D LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315C, 315D L, 318C, 318D L, 318D2 L, 319C, 319D, 319D L, 319D ...
311C, 311D LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 314C, 314D CR, 314D LCR, 314E CR, 314E LCR, 315C, 315D L, 318C, 318D L, 318D2 L, 319C, 319D, 319D L, 319D ...
6V2369
CABLE
120H, 120K, 120K 2, 120M, 12H, 12K, 12M, 12M 2, 135H, 140H, 140K, 140K 2, 140M 2, 143H, 14H, 160H, 160K, 160M 2, 163H, 16H, 2290, 236D, 2390, 2391, 242D, 246D, 2470C, 2491, 24M, 2570C, 257D, 259D, 262...
120H, 120K, 120K 2, 120M, 12H, 12K, 12M, 12M 2, 135H, 140H, 140K, 140K 2, 140M 2, 143H, 14H, 160H, 160K, 160M 2, 163H, 16H, 2290, 236D, 2390, 2391, 242D, 246D, 2470C, 2491, 24M, 2570C, 257D, 259D, 262...
0993645
CABLE-LANYARD
303.5C, 303.5D, 303.5E, 303E CR, 304, 304E, 305, 305.5, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 306, 306E, 307, 307B, 307C, 307D, 308C, 308D, 308E, 308E CR, 308E SR, 308E2 CR, 311, 311B, 311C, 311D LR...
303.5C, 303.5D, 303.5E, 303E CR, 304, 304E, 305, 305.5, 305.5D, 305.5E, 305C CR, 305D CR, 305E, 306, 306E, 307, 307B, 307C, 307D, 308C, 308D, 308E, 308E CR, 308E SR, 308E2 CR, 311, 311B, 311C, 311D LR...
2277567
CABLE AS
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 320C L, 321C, 322C, 322C FM, 325C, 325C FM, 330C, 330C FM, 330C L, 330C MH, M325C MH
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 320C L, 321C, 322C, 322C FM, 325C, 325C FM, 330C, 330C FM, 330C L, 330C MH, M325C MH
2070207
CABLE AS
308C, 308D, 314C, 314D LCR, 321C, 321D LCR, 325C, 328D LCR
308C, 308D, 314C, 314D LCR, 321C, 321D LCR, 325C, 328D LCR
2041569
CABLE AS
320C, 320C FM, 321C, 322C
320C, 320C FM, 321C, 322C
2677733
CABLE AS
321C
321C
2677734
CABLE AS
321C
321C
3095899
CABLE GP-GOVERNOR CONTROL
318C, 319C
318C, 319C
3502557
CABLE GP-BATTERY
3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C175-20
3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C175-20
2759855
CABLE GP-PARKING BRAKE
938G II
938G II
2034297
CABLE AS-COMMUNICATION
UPS 250
UPS 250
2466853
CABLE AS
3406C, 3456, C15, C18, C9
3406C, 3456, C15, C18, C9
2452085
CABLE AS
3406C, 3456, C15, C18, C9
3406C, 3456, C15, C18, C9
2452084
CABLE AS
3406C, 3456, C15, C18, C9
3406C, 3456, C15, C18, C9
2924539
CABLE AS-COMMUNICATION
Caterpillar
Caterpillar
2064010
CABLE AS-COMMUNICATION
Caterpillar
Caterpillar
1797191
CABLE AS-COMMUNICATION
Caterpillar
Caterpillar