J1939 Code and Description CDL Code and Description Comments
4334–7
Aftertreatment #1 DEF #1 Pressure (absolute) : Not Responding Properly 3090–7
Aftertreatment #1 DEF Pressure #1 Sensor : Not Responding Properly Diesel Exhaust Fluid (DEF) pump pressure is not stable after the initial priming sequence or the DEF pump is not able to supply DEF after the line heaters have been energized and a heating cycle has been completed.
4334-18
Aftertreatment #1 DEF #1 Pressure (absolute) : Low - moderate severity (2) E931 (2)
Low Aftertreatment #1 DEF Pressure #1 DEF system pressure dropped below the acceptable threshold during dosing.
5392-31
Aftertreatment #1 DEF Dosing Unit #1 Loss of Prime E1370 (2)
Aftertreatment #1 DEF Dosing Unit #1 Loss of Prime DEF system pressure was not achieved during priming.
Table 2
Troubleshooting Test Steps Values Results
1. Check the DEF Tank Filler Cap.
A. Clean dirt and debris from around the tank cap before removing the cap. Blockages can be caused by a build-up of dirt and debris around the cap.
Note : A blocked DEF filler cap can cause a 5392-31 or E1370 (2) code.
B. Remove and inspect the filler cap for blockages.
DEF Filler Cap
Result : A blockage was not found.
Proceed to Test Step 2.
Result : A blockage was found.
Repair : Rinse the cap gently with clean water or replace the cap. The cap contains a membrane so care must be taken not to damage the membrane. If the cap cannot be cleaned, replace the cap.
Proceed to Test Step 2.
2. Check the DEF Gauge.
A. Turn the keyswitch to ON. Do not start the engine.
B. Check the current position of the DEF gauge.
C. Turn the keyswitch to OFF.
D. Clean dirt and debris from around the tank cap before removing the cap. Add or remove DEF from the DEF tank.
Note : Only use DEF that meets ISO 22241 quality standards.
E. Turn the keyswitch to ON. Do not start the engine.
F. Check for a change in the DEF gauge position.
DEF Gauge
Result : The gauge did not move by adding or removing DEF from the tank.
Proceed to Test Step 3.
Result : The gauge moved by adding or removing DEF from the tank.
Proceed to Test Step 4.
3. Check the Electrical Connection at the DEF Tank Header.
A. Turn the keyswitch to OFF.
B. Inspect the electrical connections to the DEF tank header. Refer to Troubleshooting, "Electrical Connectors - Inspect" for further information.
C. Inspect the connections for corrosion or loose wires.
Electrical Connections
Result : The electrical connections are free of corrosion and loose wires.
Repair : Replace the DEF tank header. Refer to Disassembly and Assembly, Manifold (DEF Heater) - Remove and Install.
Proceed to Test Step 10.
Result : The electrical connections are not free of corrosion or loose wires.
Repair : Make the necessary repairs.
Proceed to Test Step 10.
4. Inspect the DEF Lines for Leaks.
A. Turn the keyswitch to ON. Do not start the engine.
B. Connect to the A6:E2 Electronic Control Module (ECM) using Cat® Electronic Technician (ET).
C. Navigate to "Diagnostics Tests".
D. Perform the "DEF Dosing System Verification Test" to pressurize the system.
E. Inspect all DEF lines from the tank to
Parts cable Caterpillar catalog:
3326816
CABLE AS
Caterpillar
Caterpillar
3322557
CABLE AS
Caterpillar
Caterpillar
3322556
CABLE AS
Caterpillar
Caterpillar
3319010
CABLE AS
Caterpillar
Caterpillar
3317026
CABLE AS
Caterpillar
Caterpillar
3317025
CABLE AS
Caterpillar
Caterpillar
3351492
CABLE AS
Caterpillar
Caterpillar
3348143
CABLE AS
Caterpillar
Caterpillar
3336413
CABLE AS
Caterpillar
Caterpillar
3333995
CABLE AS
Caterpillar
Caterpillar
3333993
CABLE AS
Caterpillar
Caterpillar
3327382
CABLE AS
Caterpillar
Caterpillar