3893517 CABLE AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA3893517
389-3517
3893517
CA3893517
389-3517
3893517
Weight: 0.61 pounds 0 kg.
Information:
Illustration 4 g01959833
P16 harness connector for the ITSM
(r) Cylinder 1 (yellow)
(f) Cylinder 1 (red)
(R) Cylinder 2 (yellow)
(W) Cylinder 2 (red)
(J) Cylinder 3 (yellow)
(E) Cylinder 3 (red)
(k) Cylinder 4 (yellow)
(a) Cylinder 4 (red)
(AC) Cylinder 5 (yellow)
(v) Cylinder 5 (red)
(V) Cylinder 6 (yellow)
(M) Cylinder 6 (red)
(q) Cylinder 7 (yellow)
(e) Cylinder 7 (red)
(AE) Cylinder 8 (yellow)
(y) Cylinder 8 (red)
(H) Cylinder 9 (yellow)
(B) Cylinder 9 (red)
(Z) Cylinder 10 (yellow)
(P) Cylinder 10 (red)
(u) Cylinder 11 (yellow)
(j) Cylinder 11 (red)
(AG) Cylinder 12 (yellow)
(AA) Cylinder 12 (red)
(g) Left turbocharger inlet (yellow)
(X) Left turbocharger inlet (red)
(C) Left turbocharger outlet (yellow)
(F) Left turbocharger outlet (red)
(N) Right turbocharger inlet (yellow)
(S) Right turbocharger inlet (red)
Disconnect the 54-pin connector from the ITSM. Thoroughly inspect the 54-pin connectors. Ensure that the connectors are in good condition. Note: When the 54-pin connectors are disconnected, an active "current below normal" diagnostic code will be generated for all of the thermocouples. This is normal. Only pay attention to the diagnostic codes for the suspect thermocouple.
Access the "Active Diagnostic" screen for the ITSM on Cat ET. Allow a minimum of 30 seconds for any diagnostic codes to be generated. Observe the "Active Diagnostic" screen.
Install a jumper wire into the terminals for the suspect sensor on the 54-pin connector on the ITSM. For identification of the terminals, refer to Illustration 1.
Observe the "Active Diagnostic" screen. Allow a minimum of 30 seconds for any diagnostic codes to be generated. Expected Result:When the 54-pin connectors were disconnected, an "current below normal" diagnostic code was generated for the suspect sensor. When the jumper wire was installed, a "voltage below normal" diagnostic code was generated.Results:
Yes - When the 54-pin connectors were disconnected, an "current below normal" diagnostic code was generated for the suspect sensor. When the jumper wire was installed, a "voltage below normal" diagnostic code was generated. The ITSM is OK. There is a problem in the harness between the ITSM and the connector for the suspect thermocouple.Repair: Remove the jumper wire. Replace the harness in order to ensure reliable operation. Clear the logged diagnostic codes and verify that the problem is resolved.All of the wiring from the thermocouples to the ITSM must be type K. The polarity of the wires from each thermocouple to the ITSM must be maintained in order for the ITSM to read the correct temperatures.STOP
No - Either of the following results or both of the results occurred: When the 54-pin connectors were disconnected, an "current below normal" diagnostic code was not generated for the suspect sensor. When the jumper wire was installed, a "voltage below normal" diagnostic code was not generated. There may be a problem with the ITSM.Repair: Perform the following steps:
Remove the jumper wire from the connector on the ITSM.
Temporarily install a new ITSM. Refer to Troubleshooting, "Control Module - Replace".
If the problem is resolved with the new ITSM, install the original ITSM and verify that the problem returns. If the new ITSM operates correctly and the original ITSM does not operate correctly, replace the original ITSM. Refer to Troubleshooting, "Control Module -
Parts cable Caterpillar catalog:
3893516
CABLE AS
Caterpillar
Caterpillar
3893515
CABLE AS
Caterpillar
Caterpillar
3893514
CABLE AS
Caterpillar
Caterpillar
3893513
CABLE AS-
Caterpillar
Caterpillar
3893511
CABLE AS
Caterpillar
Caterpillar
3893510
CABLE AS-GND
Caterpillar
Caterpillar
3894662
CABLE AS
Caterpillar
Caterpillar
3894652
CABLE AS
Caterpillar
Caterpillar
3894642
CABLE AS
Caterpillar
Caterpillar
3894632
CABLE AS
Caterpillar
Caterpillar
3893624
CABLE AS
Caterpillar
Caterpillar
3893558
CABLE AS
Caterpillar
Caterpillar