Test Preparation
Start and run the engine. Operate the elevator controls until hydraulic oil is at normal operating temperature.
Stop the engine.
Illustration 7 g02633216
View of the top of the pump
Install Tooling (A) or Tooling (B) to test ports (1) and (2).Test Procedure
Start and run the engine. Increase engine speed to high idle.
Record readings from Tooling (A) or Tooling (B).
Make sure that the elevator control is in the neutral position.
Slowly begin to move the elevator drive control in one direction. The elevator drive should start to move by the time Tooling (A) or (B) reads 500 kPa (73 psi).
Stop the engine.
Repeat Steps 1 through 5 with the elevator drive in the opposite direction.Maximum Pressure Override
Introduction
This test will verify the maximum operating pressure of the elevator drive.Required Tools
Illustration 8 g02571852
Tooling (A) 198-4240 Digital Pressure Indicator Gp
Table 5
Tool Item Qty Part No Description
A 198-4240 Digital Pressure Indicator Gp
A1 1 198-4234 Digital Indicator
A2 2 143-4066 Pressure Sensor Gp
(0 kPa TO 51,710 kPa (7,500 psi))
A3 2 198-4236 Adapter Cable As
Illustration 9 g02726620
Tooling (B) manual gauges
Table 6
Tool Item Qty Part Number Description
B B1 1 8T-0861 Pressure Gauge 0 kPa TO 60,000 kPa (0 psi TO 8,7000 psi)
B2 1 6V-3989 Fitting
B3 1 6V-4143 Quick Connect Coupler
B4 1 177-7862 Hose As Test Preparation
Illustration 10 g02535043
View of chained elevator
Secure the elevator on the left and the right side with chains that are heavy enough to keep the elevator from moving.
Illustration 11 g02649244
Rear view of tractor "H" series service ports
Illustration 12 g03476180
View of tractor "K" series service ports
Install Tooling (A) or tooling (B) to ports (1), (2).Test Procedure
Take up the slack in the chain that restrains the elevator from moving while the engine is at low idle. Slowly place the elevator control in the FORWARD position.
When the chain that restrains the elevator is tight, bring the engine to high-idle and keep the elevator control in the FORWARD position.
Record readings from Tooling (A) or Tooling (B). The maximum pressure for the pump is 43500 1000 kPa (6309.24 145.04 psi).
Return the elevator control back to the NEUTRAL position.
Repeat Steps 1 through 4 for Reverse.
Shut down the machine.
Start and run the engine. Operate the elevator controls until hydraulic oil is at normal operating temperature.
Stop the engine.
Illustration 7 g02633216
View of the top of the pump
Install Tooling (A) or Tooling (B) to test ports (1) and (2).Test Procedure
Start and run the engine. Increase engine speed to high idle.
Record readings from Tooling (A) or Tooling (B).
Make sure that the elevator control is in the neutral position.
Slowly begin to move the elevator drive control in one direction. The elevator drive should start to move by the time Tooling (A) or (B) reads 500 kPa (73 psi).
Stop the engine.
Repeat Steps 1 through 5 with the elevator drive in the opposite direction.Maximum Pressure Override
Introduction
This test will verify the maximum operating pressure of the elevator drive.Required Tools
Illustration 8 g02571852
Tooling (A) 198-4240 Digital Pressure Indicator Gp
Table 5
Tool Item Qty Part No Description
A 198-4240 Digital Pressure Indicator Gp
A1 1 198-4234 Digital Indicator
A2 2 143-4066 Pressure Sensor Gp
(0 kPa TO 51,710 kPa (7,500 psi))
A3 2 198-4236 Adapter Cable As
Illustration 9 g02726620
Tooling (B) manual gauges
Table 6
Tool Item Qty Part Number Description
B B1 1 8T-0861 Pressure Gauge 0 kPa TO 60,000 kPa (0 psi TO 8,7000 psi)
B2 1 6V-3989 Fitting
B3 1 6V-4143 Quick Connect Coupler
B4 1 177-7862 Hose As Test Preparation
Illustration 10 g02535043
View of chained elevator
Secure the elevator on the left and the right side with chains that are heavy enough to keep the elevator from moving.
Illustration 11 g02649244
Rear view of tractor "H" series service ports
Illustration 12 g03476180
View of tractor "K" series service ports
Install Tooling (A) or tooling (B) to ports (1), (2).Test Procedure
Take up the slack in the chain that restrains the elevator from moving while the engine is at low idle. Slowly place the elevator control in the FORWARD position.
When the chain that restrains the elevator is tight, bring the engine to high-idle and keep the elevator control in the FORWARD position.
Record readings from Tooling (A) or Tooling (B). The maximum pressure for the pump is 43500 1000 kPa (6309.24 145.04 psi).
Return the elevator control back to the NEUTRAL position.
Repeat Steps 1 through 4 for Reverse.
Shut down the machine.
Parts cable Caterpillar catalog:
4865789
CABLE AS
Caterpillar
Caterpillar
4865521
CABLE-METHANE
Caterpillar
Caterpillar
4865519
CABLE-METHANE
Caterpillar
Caterpillar
4859935
CABLE GP
Caterpillar
Caterpillar
4859472
CABLE
Caterpillar
Caterpillar
4859467
CABLE AS
Caterpillar
Caterpillar
4867558
CABLE
Caterpillar
Caterpillar
4867553
CABLE
Caterpillar
Caterpillar
4867551
CABLE AS
Caterpillar
Caterpillar
4867550
CABLE AS
Caterpillar
Caterpillar
4867518
CABLE AS-POWER
Caterpillar
Caterpillar
4865791
CABLE AS
Caterpillar
Caterpillar