5V4734 CABLE AS Caterpillar parts
814B, 815B, 816B, 950B, 950B/950E, 966D
Rating:
Alternative (cross code) number:
CA5V4734
5V-4734
5V4734
CA5V4734
5V-4734
5V4734
Weight: 1 pounds 0 kg.
Information:
LENGTH
1996.6
mm
MINIMUM BEND RADIUS
178
mm
TRAVEL
32
mm
LANDFILL COMPACTOR, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$26.15
16 Sep 2023
Amazon.com
CTP 5V4734 Cable for Models 814B/815B/816B/950B/950B/950E/966D Caterpillar
CTP For Model 814B/815B/816B/950B/950B/950E/966D Caterpillar || Sold in each || Easy in-and-out fit
CTP For Model 814B/815B/816B/950B/950B/950E/966D Caterpillar || Sold in each || Easy in-and-out fit
$30.04
30 Aug 2023
Amazon.com
CTP 5V4734 Cable for Models 814B/815B/816B/950B/950B/950E/966D Caterpillar
CTP For Model 814B/815B/816B/950B/950B/950E/966D Caterpillar || Sold in each || Easy in-and-out fit
CTP For Model 814B/815B/816B/950B/950B/950E/966D Caterpillar || Sold in each || Easy in-and-out fit
Compatible equipment models: 5V4734:
Information:
Illustration 1 g00578242
Upper Display With SP Fault Code SP1 Showing
Illustration 2 g00578243
System Schematic For Spare Fault InputsA spare fault informs the operator of an undesirable condition (fault) that exists. The spare inputs are programmed into the GSC+ to meet the requirements of the customer or application. An active spare input causes an alarm fault or a shutdown fault. For programming of the spare inputs, see System Operation, "Spare Input/Output Programming OP6". The programmer (customer, operator or service personnel) should make a note of the actual conditions that cause an SP fault code to be shown on the upper display. The GSC+ does not diagnose the spare inputs. Spare faults are not recorded in the fault log.The GSC+ treats an active input state as a fault. The active state can be programmed on the GSC+ as a high voltage level or a low voltage level. The factory default is a low voltage level. A high level is within the range of +5 DCV to + battery. If the input remains floating, the GSC+ pulls up the input voltage to 10.5 DCV. In this case, the input is treated as high level. An example of a floating input would be an open switch. A low level on the input is "B-" (ground).When a spare fault occurs, the GSC+ determines the type of fault. There are two types of faults: alarm and shutdown. Then, the GSC+ FLASHES the corresponding fault alarm indicator or fault shutdown indicator. The SP fault code is immediately shown on the upper display for a shutdown type of fault. For an alarm type of fault, the alarm codes key is pressed first. Then, the SP fault code is shown on the upper display. After a spare fault is corrected or a spare fault is not present, the SP fault code is no longer shown on the upper display.
Table 1
Spare Fault Codes    
Spare
Fault Code    GSC+
Connector
Contact    Terminal
Strip    Related
Setpoints (1)    
SP1
Spare Fault 1     23     SP1     SP01, SP02, SP03    
SP2
Spare Fault 2     24     SP2     SP04, SP05, SP06    
SP3
Spare Fault 3     25     SP3     SP07, SP08, SP09    
SP4
Spare Fault 4     29     SP4     SP10, SP11, SP12    
( 1 ) See Systems Operation, "Spare Input/Output Programming OP6".SP fault codes are associated with the spare inputs. The SP fault code that is shown on the upper display identifies the spare input that caused the alarm fault or the shutdown fault. The spare inputs are accessed on the terminal strip within the control panel on an inside wall.When an SP fault code is showing on the upper display, check the notes which were made by the service personnel in order to determine the cause.The spare fault inputs can be used with the factory installed options and the customer installed options. The following items are the factory options for the spare fault input: ground fault, low fuel level, high fuel level, high generator winding temperature and high generator bearing
Caterpillar parts catalog:
Parts cable Caterpillar catalog:
7P6682
CABLE AS
416, 416B, 416C, 426B, 426C, 428, 428B, 428C, 436, 436C, 438B, 438C, 446, 446B, 446D, 517, 527, 561M, 561N, 572R, 589, 814B, 814F, 815B, 815F, 816F, 834B, 943, 950B, 950B/950E, 950F, 950F II, 953, 953...
416, 416B, 416C, 426B, 426C, 428, 428B, 428C, 436, 436C, 438B, 438C, 446, 446B, 446D, 517, 527, 561M, 561N, 572R, 589, 814B, 814F, 815B, 815F, 816F, 834B, 943, 950B, 950B/950E, 950F, 950F II, 953, 953...
9X0390
CABLE AS
916, 926A, 936, 936F, 966D, G936, IT18B, IT28B
916, 926A, 936, 936F, 966D, G936, IT18B, IT28B
9X0391
CABLE AS
814F, 815F, 816F, 966D, 966F, 966F II, 970F
814F, 815F, 816F, 966D, 966F, 966F II, 970F
3V2783
CABLE ASSEM.
814B, 815B, 816B, 824C, 966D, 980C
814B, 815B, 816B, 824C, 966D, 980C
4V2157
CABLE ASSEM.
815B, 950B, 966D
815B, 950B, 966D
5V4732
CABLE AS
814B, 815B, 816B, 950B, 950B/950E, 966D
814B, 815B, 816B, 950B, 950B/950E, 966D
4V4835
CABLE AS
950B, 950B/950E
950B, 950B/950E
7T8195
CABLE AS
814B, 966D
814B, 966D
7T8194
CABLE AS
950B, 950B/950E
950B, 950B/950E
9X1395
CABLE AS
950B, 950B/950E
950B, 950B/950E
7T1971
CABLE AS
814B, 815B, 816B, 824C, 825C, 826C
814B, 815B, 816B, 824C, 825C, 826C
4V8277
CABLE GP-GOVERNOR CONTROL
815B, 825C, 826C
815B, 825C, 826C
5V4732
CABLE AS
814B, 815B, 816B, 950B, 950B/950E, 966D
814B, 815B, 816B, 950B, 950B/950E, 966D
8V8022
CABLE AS
966C, 966R
966C, 966R
7V9223
CABLE AS
966C, 966R
966C, 966R
5C9987
CABLE AS
966D
966D
5C9417
CABLE AS
966D
966D
8P5236
CABLE AS
988B, D9H
988B, D9H
7T8194
CABLE AS
950B, 950B/950E
950B, 950B/950E
7T8195
CABLE AS
814B, 966D
814B, 966D
6C0503
CABLE AS
950B, 966D
950B, 966D
6C0502
CABLE AS
966D
966D
9V5146
CABLE AS
980C
980C
4V4835
CABLE AS
950B, 950B/950E
950B, 950B/950E