7S2774 CABLE ASSEM. Caterpillar parts
983
Rating:
Alternative (cross code) number:
CA7S2774
7S-2774
7S2774
CA7S2774
7S-2774
7S2774
Weight: 3 pounds 1 kg.
TRACK LOADER,
Compatible equipment models: 7S2774:
Information:
fault indicator on the GSC flashes four to five times per second (4 to 5 Hz). The displays of the GSC may be unclear. The GSC does not respond to any position of the engine control switch (ECS).This is an internal fault of the GSC that can be temporary or permanent. The fault is caused by a component failure in the GSC. The fault could also be caused by extremely severe electromagnetic interference or radio frequency interference. The relays in the relay module are automatically turned off when this fault occurs.
The engine will shut down if the engine is equipped with the 2301A governor.
The engine will run at idle speed if the engine is equipped with the 8290 governor. The ESPB will shut down the engine.
This fault will shut down ETR engines with mechanical governors.
This fault will cause ETS engines with mechanical governors to run at idle speed. The ESPB will shut down the engine.
Reset the GSC.
Turn the ECS to OFF/RESET. If the GSC does not power down, remove the jumper that connects terminals 6 and 9 on the ECS.
Turn the ECS to STOP.Expected Result: The GSC should power up with an identifiable display. The GSC should respond to the ECS. Results:
OK - The GSC operates correctly. Therefore, the fault is gone. STOP.
NOT OK - The GSC does NOT operate correctly and the fault shutdown indicator still flashes at a rate of four to five times a second (4 to 5 Hz). Therefore, the GSC is faulty. Replace the GSC. See Testing And Adjusting, "EMCP Electronic Control (Generator Set) - Replace". STOP.
The engine will shut down if the engine is equipped with the 2301A governor.
The engine will run at idle speed if the engine is equipped with the 8290 governor. The ESPB will shut down the engine.
This fault will shut down ETR engines with mechanical governors.
This fault will cause ETS engines with mechanical governors to run at idle speed. The ESPB will shut down the engine.
Reset the GSC.
Turn the ECS to OFF/RESET. If the GSC does not power down, remove the jumper that connects terminals 6 and 9 on the ECS.
Turn the ECS to STOP.Expected Result: The GSC should power up with an identifiable display. The GSC should respond to the ECS. Results:
OK - The GSC operates correctly. Therefore, the fault is gone. STOP.
NOT OK - The GSC does NOT operate correctly and the fault shutdown indicator still flashes at a rate of four to five times a second (4 to 5 Hz). Therefore, the GSC is faulty. Replace the GSC. See Testing And Adjusting, "EMCP Electronic Control (Generator Set) - Replace". STOP.
Caterpillar parts catalog:
Parts cable Caterpillar catalog:
8F4667
CABLE (52'' long)
6A, 7A, 7G, 8 SR, 8A
6A, 7A, 7G, 8 SR, 8A
5H4658
CABLE
977H
977H
2S3838
CABLE ASSEM.
977H
977H
2S5875
CABLE ASSEM.
977H
977H
3K4772
CABLE ASSEM.
910, 955H, 977H
910, 955H, 977H
5H3631
CABLE ASSEM.
12E, 910, 931B, D3, D3B, IT12
12E, 910, 931B, D3, D3B, IT12
4N3695
CABLE ASSEM.
776C, 983
776C, 983
8S6938
CABLE ASSEM.
561D, 983, D5B, D6D, D9G
561D, 983, D5B, D6D, D9G
3P4564
CABLE ASSEM.
55, 58
55, 58