1043427 CAMSHAFT GP Caterpillar parts
3176B
Rating:
Alternative (cross code) number:
CA1043427
104-3427
1043427
CA1043427
104-3427
1043427
MARINE ENGINE,
Compare Prices:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 1043427:
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Information:
Possible causes for an FMI 3 diagnostic code are:
The signal circuit is shorted to another voltage circuit.
A sensor circuit is open or has a poor connection.
The sensor has failed.
The ECM has failed. A failure of the ECM is unlikely.Possible causes for an FMI 4 diagnostic code are:
The sensor has failed.
The signal circuit in the machine harness is shorted to ground.
The ECM has failed. A failure of the ECM is unlikely.
Illustration 1 g03650642
Schematic of the Analog Active SensorsNote: The diagram above is a simplified schematic of the Machine ECM and the Analog Active connections. The schematic is electrically correct. However, not all of the possible harness connectors are shown. Refer to the latest revision of Electrical Schematic, UENR4017 for the complete schematic.Diagnostic Trouble Code Procedure
Note: Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that the diagnostic code is active before performing a troubleshooting procedure. For sensors powered via the fuse panel, check the condition of the appropriate fuse before beginning the troubleshooting procedure.
Table 2
Troubleshooting Test Steps    Values    Results    
1. Identify Active DTC Code Associated With Sensor Circuit     Code present     FMI 3 diagnostic code, proceed
The signal circuit is shorted to another voltage circuit.
A sensor circuit is open or has a poor connection.
The sensor has failed.
The ECM has failed. A failure of the ECM is unlikely.Possible causes for an FMI 4 diagnostic code are:
The sensor has failed.
The signal circuit in the machine harness is shorted to ground.
The ECM has failed. A failure of the ECM is unlikely.
Illustration 1 g03650642
Schematic of the Analog Active SensorsNote: The diagram above is a simplified schematic of the Machine ECM and the Analog Active connections. The schematic is electrically correct. However, not all of the possible harness connectors are shown. Refer to the latest revision of Electrical Schematic, UENR4017 for the complete schematic.Diagnostic Trouble Code Procedure
Note: Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that the diagnostic code is active before performing a troubleshooting procedure. For sensors powered via the fuse panel, check the condition of the appropriate fuse before beginning the troubleshooting procedure.
Table 2
Troubleshooting Test Steps    Values    Results    
1. Identify Active DTC Code Associated With Sensor Circuit     Code present     FMI 3 diagnostic code, proceed
Parts camshaft Caterpillar catalog:
1105140
CAMSHAFT AS
3176B
3176B
7E8113
CAMSHAFT AS
3606, C280-6
3606, C280-6
2474921
CAMSHAFT GP
3054C, TH210, TH215
3054C, TH210, TH215
2246345
CAMSHAFT GP
3054B, TH210, TH215
3054B, TH210, TH215
3332238
CAMSHAFT GP
3508C
3508C
2201363
CAMSHAFT GP
TH103, TH350B, TH355B, TH460B, TH62, TH63, TH82, TH83
TH103, TH350B, TH355B, TH460B, TH62, TH63, TH82, TH83
7E7187
CAMSHAFT AS
3616
3616
1799534
CAMSHAFT AS
3616, C280-16
3616, C280-16
3825085
CAMSHAFT GP
G3516B
G3516B
1W0862
CAMSHAFT GP
3612
3612
7E8150
CAMSHAFT GP
3612
3612