3321364 CAMSHAFT GP Caterpillar parts
C2.2
Rating:
Alternative (cross code) number:
CA3321364
332-1364
3321364
CA3321364
332-1364
3321364
INDUSTRIAL ENGINE,
Compatible equipment models: 3321364:
Information:
Saving Display Settings or Machine Settings
Note: The contents of the "Setup Menu" dialog are configurable at the site. The number of items in the "Setup Menu" may vary depending on the "Operator Configuration" settings of the system. Refer to the manager of the site if a specific option is not available.Use the "Save Settings" dialog in order to save the display settings and machine settings to a data card. From this dialog, you can save all the settings in the "Setup Menu - Configuration" dialog.You can customize and save the text items that are shown on the guidance screens by saving the display settings.In order To access the "Save Settings" dialog complete the following steps:
Make sure that a data card is inserted in the Display.
Illustration 1 g01373490
AccuGrade GPS Display (1) LCD Screen (2) Soft Key Labels (3) Soft Keys (4) Next Key (5) Escape Key (6) Slot for Data card (7) Power Key (8) Menu Key (9) Arrow Keys (10) OK Key (11) Zoom out Key (12) Zoom in Key
Press the "Menu" key (8) from any Guidance screen.
Illustration 2 g01439415
From the "Setup Menu - Configuration" dialog, press the Down arrow or the Up arrow until "Save Settings" is highlighted.
Press the "OK" key (10) .
Illustration 3 g01270136
The "Save Settings" dialog appears. Use the Arrow keys (9) in order to select either "Display Settings" or "Machine Settings".
Illustration 4 g01270137
Press the "OK" key (10) .The dialog that is shown in Illustration 4 appears.The default file name for display settings is "DISPLAY NN". The default file name for machine settings is "EXCAVATOR(HEX) NN"."NN" is a two digit number starting at 01 and incrementing with each new settings file that is saved.The number assigned to a new Display settings file is one more than any similarly named settings file already on the data card. For example, if there is already a dozer machine settings file (called EXCAVATOR(HEX) 01) on the card, the AccuGrade System assigns the name EXCAVATOR(HEX) 02.You can also save the settings to a file name that is more descriptive. For example, you can use a name such as "345C HEX". Use the arrow keys to edit the default name.Note: You cannot use the Display to overwrite or delete an existing settings file.
In order to save the settings to the data card, press the "OK" key (10). After saving, the "Save Settings" dialog appears. Press the Escape key (4) in order to go back to the "Setup Menu" dialog.In order to close the dialog without saving the configuration to the data card, press the Escape key (4). The "Save Settings" dialog appears.Note: If you change the default name, and then press the Escape key (5), you are prompted to confirm that you want to cancel your changes.
Note: The contents of the "Setup Menu" dialog are configurable at the site. The number of items in the "Setup Menu" may vary depending on the "Operator Configuration" settings of the system. Refer to the manager of the site if a specific option is not available.Use the "Save Settings" dialog in order to save the display settings and machine settings to a data card. From this dialog, you can save all the settings in the "Setup Menu - Configuration" dialog.You can customize and save the text items that are shown on the guidance screens by saving the display settings.In order To access the "Save Settings" dialog complete the following steps:
Make sure that a data card is inserted in the Display.
Illustration 1 g01373490
AccuGrade GPS Display (1) LCD Screen (2) Soft Key Labels (3) Soft Keys (4) Next Key (5) Escape Key (6) Slot for Data card (7) Power Key (8) Menu Key (9) Arrow Keys (10) OK Key (11) Zoom out Key (12) Zoom in Key
Press the "Menu" key (8) from any Guidance screen.
Illustration 2 g01439415
From the "Setup Menu - Configuration" dialog, press the Down arrow or the Up arrow until "Save Settings" is highlighted.
Press the "OK" key (10) .
Illustration 3 g01270136
The "Save Settings" dialog appears. Use the Arrow keys (9) in order to select either "Display Settings" or "Machine Settings".
Illustration 4 g01270137
Press the "OK" key (10) .The dialog that is shown in Illustration 4 appears.The default file name for display settings is "DISPLAY NN". The default file name for machine settings is "EXCAVATOR(HEX) NN"."NN" is a two digit number starting at 01 and incrementing with each new settings file that is saved.The number assigned to a new Display settings file is one more than any similarly named settings file already on the data card. For example, if there is already a dozer machine settings file (called EXCAVATOR(HEX) 01) on the card, the AccuGrade System assigns the name EXCAVATOR(HEX) 02.You can also save the settings to a file name that is more descriptive. For example, you can use a name such as "345C HEX". Use the arrow keys to edit the default name.Note: You cannot use the Display to overwrite or delete an existing settings file.
In order to save the settings to the data card, press the "OK" key (10). After saving, the "Save Settings" dialog appears. Press the Escape key (4) in order to go back to the "Setup Menu" dialog.In order to close the dialog without saving the configuration to the data card, press the Escape key (4). The "Save Settings" dialog appears.Note: If you change the default name, and then press the Escape key (5), you are prompted to confirm that you want to cancel your changes.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts camshaft Caterpillar catalog:
3707834
CAMSHAFT GP
C2.2
C2.2
3642522
CAMSHAFT GP
C2.2
C2.2
3411359
CAMSHAFT GP
C2.2
C2.2
3255663
CAMSHAFT GP
C2.2
C2.2
3283293
CAMSHAFT GP
C2.2
C2.2
3239147
CAMSHAFT GP
C2.2
C2.2
3654292
CAMSHAFT GP
C2.2
C2.2
3737284
CAMSHAFT GP
C2.2
C2.2
4206419
CAMSHAFT GP
C2.2
C2.2
4416514
CAMSHAFT GP
C2.2
C2.2
3654287
CAMSHAFT GP
C2.2
C2.2
3096733
CAMSHAFT AS
216B, 216B3, 3024C, AP-255E, BB-621C, C2.2, CB-34, CB34B, CB34B XW, CC34B
216B, 216B3, 3024C, AP-255E, BB-621C, C2.2, CB-34, CB34B, CB34B XW, CC34B
4184457
CAMSHAFT GP
C0.7
C0.7
3676779
CAMSHAFT GP
C0.7
C0.7
3651608
CAMSHAFT GP
C0.7
C0.7
3387276
CAMSHAFT GP
C0.7
C0.7
3119624
CAMSHAFT AS
C0.7
C0.7
3966916
CAMSHAFT GP
C1.5
C1.5
3539334
CAMSHAFT GP
CG137-12
CG137-12
3338957
CAMSHAFT GP
3508B
3508B
3945020
CAMSHAFT GP
C7.1
C7.1
3485209
CAMSHAFT GP
C13, C13 XQ350, CX31-C13I
C13, C13 XQ350, CX31-C13I
3250398
CAMSHAFT GP
3508C
3508C
3654287
CAMSHAFT GP
C2.2
C2.2