A command prompt window should appear.
Illustration 68 g03674004
Type "ping" followed by a space and then the device IP address, and press the "Enter" key on the keyboard. Refer to Table 7, and Table 8.
A proper ping command should look like "ping xxx.xxx.xxx.xxx".
A proper continuous ping command should look like "ping xxx.xxx.xxx.xxx -t".
A successful ping will indicate that all packets have been received.
An unsuccessful ping will indicate that all packets have not been received.Note: To initiate a continuous ping, type "ping" followed by a space, the device IP address, a space, -t, and press the "Enter" key on the keyboard.
Table 7
Component IP Matrix
On-board
Service PC
(TCP/IPv4) On-board Router
(Internal Lan side) (1) Machine On-board Router
(External Wan side) RCM (System Master) (1)
Settings Web Page 165.26.78.1(2) 165.26.78.1(2) 165.26.79.2:3785(2)
IP Address 165.26.79.10(2) 165.26.78.1(2) (3) 165.26.79.2(2)
Subnet Mask 255.255.0.0(2) 255.255.254.0(2) (3) 255.255.254.0(2)
Gateway 165.26.78.1(2) (3) 165.26.78.1(2)
(1) Can only access from the (LAN) Ethernet service port
(2) System defined IP information (Do not change)
(3) Customer defined IP information
Table 8
Component IP Matrix
Off-board
Service PC
(TCP/IPv4) Off-board Router
(Internal Lan side) (1) Off-board Router
(External Wan-side) Operator Station ECM (1) Operator Station PC
(TCP/IPv4)
Settings Web Page 165.26.78.1(2) 165.26.78.1 (2) 165.26.79.2:3481 (2)
IP Address 165.26.79.10 (2) 165.26.78.1 (2) (3) 165.26.79.2 (2) 165.26.79.3 (2)
Subnet Mask 255.255.0.0 (2) 255.255.254.0 (2) (3) 255.255.254.0 (2) 255.255.254.0 (2)
Gateway 165.26.78.1 (2) (3) 165.26.78.1 (2) 165.26.78.1 (2)
Destination IP address 165.26.79.3 (Touch screen PC) (2)
(1) Can only access from the (LAN) Ethernet service port
(2) System defined IP information (Do not change)
(3) Customer defined IP informationNote: Mine site IP addresses for the WAN side of the on-board and off-board routers must be defined prior to commissioning the system.Confirm Communications Between Components (LAN)
Onboard
Refer to "Connect to a Router for Configuring". Configure service PC to communicate on the Machine network.
With the GLSC in the RC position, push the manual override switch inside the cab. Then, key
Caterpillar parts catalog:
Parts cap Caterpillar catalog:
5486711
CAP AS-RAIN
Caterpillar
Caterpillar
5485497
CAP GP-RAIN
Caterpillar
Caterpillar
5485490
CAP GP-RAIN
Caterpillar
Caterpillar
5485486
CAP GP-RAIN
Caterpillar
Caterpillar
5484912
CAP
Caterpillar
Caterpillar
5473910
CAP
Caterpillar
Caterpillar
5512149
CAP
Caterpillar
Caterpillar
5512148
CAP
Caterpillar
Caterpillar
5510174
CAP AS
Caterpillar
Caterpillar
5505932
CAP AS
Caterpillar
Caterpillar
5492912
CAP AS-RAIN
Caterpillar
Caterpillar
5487277
CAP
Caterpillar
Caterpillar