7E8716 CAP/PLUG-TAPERED Caterpillar parts
3126, 3126B, 3126E, 730C, 793F, 793F AC, 793F OEM, 795F AC, 797F, C13, C175-16, C175-20, C7, C9
Rating:
Alternative (cross code) number:
CA7E8716
7E-8716
7E8716
CA7E8716
7E-8716
7E8716
Weight: 1 pounds 0 kg.
Information:
OVERALL LENGTH
19.05
mm
OD
36.51
mm
ARTICULATED TRUCK, TRUCK ENGINE,
Compatible equipment models: 7E8716:
Information:
The information in this section lists the main system earthing (grounding) arrangements (SEAs) and the wiring requirements.The normal and bypass AC lines are electronically (galvanically) isolated.Single UPS with TNS Upstream and TNS Downstream Configurations
Refer to the, "Glossary" section of this publication for a definition of TNS.Without Residual Current Protection
Illustration 1 applies to circuitry that does not have residual current protection.
Illustration 1 g02444560
Applies to input configurations that use separate normal and bypass AC lines from a single source.Note: Contact the dealership technical communicator for assistance with UPS units that are used as frequency converters.With Residual Current Protection
Electrical (galvanic) isolation between the normal and bypass AC lines is mandatory.The recommended minimum residual current protection is 3A, provided the conditions that are defined in IEC364.4-41 of the electrical code are respected.
Illustration 2 g02444819
Transformer on a bypass AC network
Illustration 3 g02444892
Transformer on a Normal AC networkNote: Adding a transformer into the "Normal AC" network reduces the overall efficiency of the installation.Single UPS with TNC Upstream and TNS, TNC, or TT Downstream Configurations
The UPS internal PE bar must be configured as a PEN bar. Refer to the "Neutral Point Connections" section of this publication for steps to configure the PE bar.For installations with an SSC or an external bypass cabinet, the internal PE bar must be configured as a PEN bar. Refer to the "Neutral Point Connections" section of this publication for steps to configure the PE bar.Single or Modular UPS Units
Illustration 4 g02446300
For configurations that use separate normal and bypass AC lines from a single source (1) Internal PEN barThe UPS output neutral must be connected to the internal PEN bar (1). Refer to Illustration 4.Parallel UPS Units with an SSC or Modular UPS Units with External Bypass CabinetThe SSC output neutral or external bypass cabinet output neutral must be connected to the internal PEN bar for the cabinet in Illustration 4. The connection between the UPS outputs and the SSC or the external bypass cabinet must be done in TNC. That is, the PEN cable must be connected to the PEN bar. Note: The load neutral terminal on the UPS, SSC, or external bypass cabinet must not be used.Any electrical components or equipment that is connected to the UPS installation output is considered downstream to the UPS installed equipment. That is, any SEAs, TNS, or TT is considered to be downstream of the UPSB505 installation output.Single UPS with IT Upstream and IT Downstream Configurations
Illustration 5 g02446319
For configurations that use separate normal and bypass AC lines from a single sourceNormal Operating ModeThe IMD1 controls the entire installation that includes UPS-related equipment that is downstream from the UPS. Power for the IMD2 is switched off by the R2 relay. The R2 relay provides upstream voltage control to the UPS.The following events will occur if the voltage is removed or if the upstream voltage protection is opened:
The R1 relay will open the IMD1 circuit to disable upstream voltage to the UPS.
The R2 relay will close the IMD2 circuit to provide upstream voltage to the UPS. The voltage will provide
Refer to the, "Glossary" section of this publication for a definition of TNS.Without Residual Current Protection
Illustration 1 applies to circuitry that does not have residual current protection.
Illustration 1 g02444560
Applies to input configurations that use separate normal and bypass AC lines from a single source.Note: Contact the dealership technical communicator for assistance with UPS units that are used as frequency converters.With Residual Current Protection
Electrical (galvanic) isolation between the normal and bypass AC lines is mandatory.The recommended minimum residual current protection is 3A, provided the conditions that are defined in IEC364.4-41 of the electrical code are respected.
Illustration 2 g02444819
Transformer on a bypass AC network
Illustration 3 g02444892
Transformer on a Normal AC networkNote: Adding a transformer into the "Normal AC" network reduces the overall efficiency of the installation.Single UPS with TNC Upstream and TNS, TNC, or TT Downstream Configurations
The UPS internal PE bar must be configured as a PEN bar. Refer to the "Neutral Point Connections" section of this publication for steps to configure the PE bar.For installations with an SSC or an external bypass cabinet, the internal PE bar must be configured as a PEN bar. Refer to the "Neutral Point Connections" section of this publication for steps to configure the PE bar.Single or Modular UPS Units
Illustration 4 g02446300
For configurations that use separate normal and bypass AC lines from a single source (1) Internal PEN barThe UPS output neutral must be connected to the internal PEN bar (1). Refer to Illustration 4.Parallel UPS Units with an SSC or Modular UPS Units with External Bypass CabinetThe SSC output neutral or external bypass cabinet output neutral must be connected to the internal PEN bar for the cabinet in Illustration 4. The connection between the UPS outputs and the SSC or the external bypass cabinet must be done in TNC. That is, the PEN cable must be connected to the PEN bar. Note: The load neutral terminal on the UPS, SSC, or external bypass cabinet must not be used.Any electrical components or equipment that is connected to the UPS installation output is considered downstream to the UPS installed equipment. That is, any SEAs, TNS, or TT is considered to be downstream of the UPSB505 installation output.Single UPS with IT Upstream and IT Downstream Configurations
Illustration 5 g02446319
For configurations that use separate normal and bypass AC lines from a single sourceNormal Operating ModeThe IMD1 controls the entire installation that includes UPS-related equipment that is downstream from the UPS. Power for the IMD2 is switched off by the R2 relay. The R2 relay provides upstream voltage control to the UPS.The following events will occur if the voltage is removed or if the upstream voltage protection is opened:
The R1 relay will open the IMD1 circuit to disable upstream voltage to the UPS.
The R2 relay will close the IMD2 circuit to provide upstream voltage to the UPS. The voltage will provide
Cat SIS web machinery list:
Parts cap Caterpillar catalog:
1779343
CAP & PROBE GP-FLUID SAMPLING
16H, 24H, 24M, 3126, 3126B, 3176, 3406, 420D, 824H, 825H, 826H, 854K, 928HZ, 988G, 994D, C-10, C-12, G3406, IT28G
16H, 24H, 24M, 3126, 3126B, 3176, 3406, 420D, 824H, 825H, 826H, 854K, 928HZ, 988G, 994D, C-10, C-12, G3406, IT28G
3497059
CAP AS-FUEL
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 2290, 2390, 2391, 2470C, 2491, 24M, 257...
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 2290, 2390, 2391, 2470C, 2491, 24M, 257...
7L4447
CAP AS-ENGINE OIL FILLER
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 5130, 5130B, 5230, 5230B, C175-16, C175-20, D346, D348, D349, D379, D379A, D379B, D398, D398A, D398B, D399, G3508, G3508B, G3512, G3512B, G3...
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 5130, 5130B, 5230, 5230B, C175-16, C175-20, D346, D348, D349, D379, D379A, D379B, D398, D398A, D398B, D399, G3508, G3508B, G3512, G3512B, G3...
8S4951
CAP
173B, 183B, 193, 225, 225D, 227, 229, 229D, 231D, 235, 235B, 235C, 235D, 245, 245B, 245D, 307B, 3116, 3126B, 3126E, 3176, 3176B, 3176C, 3196, 3406E, 3456, 345C, 345C L, 345C MH, 3512, 3516, 3516C, 360...
173B, 183B, 193, 225, 225D, 227, 229, 229D, 231D, 235, 235B, 235C, 235D, 245, 245B, 245D, 307B, 3116, 3126B, 3126E, 3176, 3176B, 3176C, 3196, 3406E, 3456, 345C, 345C L, 345C MH, 3512, 3516, 3516C, 360...
2W6225
CAP AS-OIL FILLER
214B, 3116, 3126, 3126B, 3126E, 322B L, 322C, 322C FM, 325, 325B, 325B L, 325C, 325C FM, 3406E, 3456, 365C, 365C L, 365C L MH, 374D L, 374F L, 390F L, 517, 527, 550, 561M, 561N, 570, 574, 580, 613C II...
214B, 3116, 3126, 3126B, 3126E, 322B L, 322C, 322C FM, 325, 325B, 325B L, 325C, 325C FM, 3406E, 3456, 365C, 365C L, 365C L MH, 374D L, 374F L, 390F L, 517, 527, 550, 561M, 561N, 570, 574, 580, 613C II...
1570670
CAP-DUST
1090, 1190, 1190T, 120H, 120K, 120K 2, 120M, 120M 2, 1290T, 12H, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 1390, 140G, 140H, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14H, 14M, 160H, 160K, ...
1090, 1190, 1190T, 120H, 120K, 120K 2, 120M, 120M 2, 1290T, 12H, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 1390, 140G, 140H, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 143H, 14H, 14M, 160H, 160K, ...
2066875
CAP-TUBE
120K, 120K 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140G, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 160K, 160M 2, 160M 3, 160M 3 AWD, 2864C, 3116, 3126, 3126B, 3126E, 336E, 336E H, 336E HVG, 336E L...
120K, 120K 2, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 140G, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 160K, 160M 2, 160M 3, 160M 3 AWD, 2864C, 3116, 3126, 3126B, 3126E, 336E, 336E H, 336E HVG, 336E L...
6G9333
CAP-FILLER
120G, 12G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 245, 30/30, 3406B, 3406C, 578, 583R, 587R, 611, 615, 615C, 627B, 637D, 637E, 637G, 639D, 730C, 735, 735B, 740, 740B, 777F, 777G, 797F, 814F, ...
120G, 12G, 140G, 14G, 14H, 14H NA, 160G, 16G, 16H, 16H NA, 245, 30/30, 3406B, 3406C, 578, 583R, 587R, 611, 615, 615C, 627B, 637D, 637E, 637G, 639D, 730C, 735, 735B, 740, 740B, 777F, 777G, 797F, 814F, ...
4J3754
CAP
215, 215B, 225, 229, 235, 235B, 235D, 245, 245B, 24H, 24M, 5110B, 5130, 5130B, 5230, 5230B, 528, 589, 621, 621B, 621E, 621F, 621G, 621R, 623E, 623F, 623G, 627B, 627E, 627F, 627G, 631C, 631E, 631G, 633...
215, 215B, 225, 229, 235, 235B, 235D, 245, 245B, 24H, 24M, 5110B, 5130, 5130B, 5230, 5230B, 528, 589, 621, 621B, 621E, 621F, 621G, 621R, 623E, 623F, 623G, 627B, 627E, 627F, 627G, 631C, 631E, 631G, 633...
7N5565
CAP-RADIATOR
16G, 245, 5130, 5130B, 578, 589, 621E, 621F, 623E, 623F, 627E, 627F, 627G, 631E, 633E II, 637D, 637E, 637G, 651E, 657E, 776C, 776D, 777, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789B, 789C, 793, 793B,...
16G, 245, 5130, 5130B, 578, 589, 621E, 621F, 623E, 623F, 627E, 627F, 627G, 631E, 633E II, 637D, 637E, 637G, 651E, 657E, 776C, 776D, 777, 777D, 784B, 784C, 785, 785B, 785C, 785D, 789B, 789C, 793, 793B,...
6F3931
CAP-VALVE STEM
16, 16G, 611, 613, 613B, 613C, 613C II, 613G, 615, 615C, 621, 621B, 621E, 623, 623B, 627, 627B, 630A, 630B, 631B, 631C, 633, 633C, 637, 637B, 641, 641B, 650B, 651, 651B, 657, 657B, 666, 725, 725C, 730...
16, 16G, 611, 613, 613B, 613C, 613C II, 613G, 615, 615C, 621, 621B, 621E, 623, 623B, 627, 627B, 630A, 630B, 631B, 631C, 633, 633C, 637, 637B, 641, 641B, 650B, 651, 651B, 657, 657B, 666, 725, 725C, 730...
9K7951
CAP-VALVE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
2760753
CAP-PLUG
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20, CS-54B, CS-56B, CS-68B, CS-74B, CS-78B
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20, CS-54B, CS-56B, CS-68B, CS-74B, CS-78B
2760746
CAP-PLUG
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
2760731
CAP-PLUG
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
9U7087
CAP/PLUG-TAPERED
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
9U7085
CAP/PLUG-TAPERED
793F, 793F AC, 793F OEM, 795F AC, 797F, AD60, C175-16, C175-20
793F, 793F AC, 793F OEM, 795F AC, 797F, AD60, C175-16, C175-20
9U7077
CAP/PLUG-TAPERED
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
3524934
CAP AS
993K, C15, C18, C27, C32, CX31-C18I, CX35-C18I
993K, C15, C18, C27, C32, CX31-C18I, CX35-C18I
9U7187
CAP
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
9U7082
CAP/PLUG-TAPERED
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20, CX28
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20, CX28
9U7081
CAP/PLUG-TAPERED
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
9U7080
CAP/PLUG-TAPERED
322B L, 325B L, 325C FM, 325D FM, 325D FM LL, 330B L, 330C FM, 330D FM, 793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20, M325C MH
322B L, 325B L, 325C FM, 325D FM, 325D FM LL, 330B L, 330C FM, 330D FM, 793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20, M325C MH
9U7073
CAP/PLUG-TAPERED
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20
793F, 793F AC, 793F OEM, 795F AC, 797F, C175-16, C175-20