3T1880 CHANNEL ASSEM. Caterpillar parts
D8L, D9L
Rating:
Alternative (cross code) number:
CA3T1880
3T-1880
3T1880
CA3T1880
3T-1880
3T1880
Weight: 7 pounds 3 kg.
TRACK-TYPE TRACTOR,
Information:
Illustration 1 g01447528
Schematic of the switch for QuickshiftThis diagnostic code is associated with the switch for the Quickshift. The switch is connected to two inputs of the ECM. The inputs are "Normally Open" and "Normally Closed". One of the inputs is open and the other input is grounded during proper operation. Refer to table 1.
Table 1
Status of the Quickshift Switch    
Quickshift Switch    Terminal 1
(N/C)
Wire G758-PU
J1-63    Terminal 3
(N/O)
G759-WH
J1-64    
OFF     Closed     Open    
ON     Open     Closed    The FMI 04 means that the ECM has determined that the "Normally Open" and "Normally Closed" circuits are grounded.Note: The following test procedure may create other diagnostic codes. Ignore these diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Ensure that the diagnostic code of CID 0628 FMI 04 is active before performing this procedure.Test Step 1. CHECK THE SWITCH
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the switch.
Turn the key start switch and the disconnect switch to the ON position.Expected Result:The CID 0628 FMI 04 has been replaced by CID 0628 FMI 03.Results:
OK - The CID 0628 FMI 04 has been replaced by CID 0367 FMI 03. The machine harness and the ECM are correct. Proceed to Test Step 3.
NOT OK - The CID 0628 FMI 04 is still active. Proceed to Test Step 2.Test Step 2. CHECK THE HARNESS
Turn the disconnect switch and the key start switch to the OFF position.
The machine harness remains disconnected from the switch.
Disconnect the machine harness connector(s) from the ECM.
Measure the resistance between contacts J1-64 (wire G759-WH) and J1-63 (wire G758-PU) of the machine harness to all the contacts that are used in machine harness connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
YES - Each resistance measurement is greater than 5000 ohms. The ECM has failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing And Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - One or more of the resistance measurements are less than 5 ohms. The harness has failed. The short is between J1-64 (wire G759-WH) and the circuit with the lowest resistance or the short is between J1-63 (wire G758-PU) and the circuit with the lowest resistance. Repair: Repair the wiring harness or replace the wiring harness.STOPTest Step 3. CHECK THE OPERATION OF THE SWITCH
The machine harness remains disconnected from the switch.
Connect one lead from a multimeter to contact 2 (wire 202-BK) of the harness connector for the switch.
Connect the other lead from a multimeter to contact 1 (wire G758-PU) of the harness connector for the switch.
Measure the resistance between contact 2
Caterpillar parts catalog:
Parts channel Caterpillar catalog:
6W2898
CHANNEL
816B