4196608 CHANNEL AS Caterpillar parts
385C, 385C FS
Rating:
Alternative (cross code) number:
CA4196608
419-6608
4196608
CA4196608
419-6608
4196608
EXCAVATOR, FRONT SHOVEL,
Information:
Illustration 1 g01197168
Schematic for the Pilot On/Off Solenoid ValveThis diagnostic code is recorded when the ECM detects a short to ground in the electrical path from the ECM to the solenoid. The possible causes for this diagnostic code are listed:
The internal windings for the solenoid have low impedance.
The internal windings for the solenoid are shorted.
The signal circuit from the ECM to the solenoid is shorted to ground.System Response:The machine response is listed:
The implement features will not operate.
The pilot on/off solenoid valve is off.Note: All solenoid return lines connect to contact J2-4 (wire K927-BU) of the implement ECM.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code is corrected. Note: Ensure that the diagnostic code indicator is active and that the diagnostic code is active.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position.
Observe the ON/OFF status of the diagnostic code indicator.
Disconnect the solenoid with the diagnostic code from the harness.Expected Result:The diagnostic code indicator remains active.Results:
YES - The diagnostic code indicator remains active and the diagnostic code remains active. The harness has failed or the ECM has failed. Proceed to Test Step 2.
NO - The diagnostic code indicator is inactive.Repair: The solenoid has failed or the connecting harness has failed. Repeat this test in order to verify the failure. Repair the solenoid or replace the solenoid. Repair the connecting harness or replace the connecting harness at the solenoid. Stop.Test Step 2. CHECK FOR A SHORTED HARNESS.
Turn the disconnect switch to the OFF position.
The solenoid valve from the previous test step remains disconnected.
Disconnect the harness from the implement ECM.
At the harness connector for the ECM, measure the resistance between contact for the failed solenoid circuit J1-12 (wire H717-BR) and contact J2-4 (ground wire K927-BU).Expected Result:The resistance is less than 5000 Ohms.Results:
YES - The resistance is less than 5000 Ohms.Repair: The harness has failed. The corresponding solenoid wire is shorted to ground in the harness. Repair the harness or replace the harness. Stop.
NO - Resistance is greater than 5000 Ohms (no continuity).Repair: The harness circuit resistance is correct. It is unlikely that the ECM has failed. Exit this procedure and perform this troubleshooting procedure again. Also recheck if the diagnostic code indicator is active for this diagnostic code. If the cause is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
Caterpillar parts catalog:
Parts channel Caterpillar catalog:
3552773
CHANNEL AS
385C, 385C FS
385C, 385C FS
2864076
CHANNEL AS
365B, 365C
365B, 365C
2551056
CHANNEL AS
365B II, 365C, 365C L
365B II, 365C, 365C L
2633657
CHANNEL AS
365B, 365B II, 365C, 385C, 385C FS
365B, 365B II, 365C, 385C, 385C FS
2253653
CHANNEL AS
365B, 365B II, 365C
365B, 365B II, 365C
2253640
CHANNEL AS
365B, 365B II, 365C
365B, 365B II, 365C
1073233
CHANNEL
330 L
330 L
4I8352
CHANNEL AS
325, 325 L, 325 LN
325, 325 L, 325 LN
2784240
CHANNEL
385C L MH
385C L MH
4196666
CHANNEL AS
385C, 385C FS
385C, 385C FS
4196663
CHANNEL AS
385C, 385C FS
385C, 385C FS