Weight: 15 pounds 7 kg.
Information:
MCS Control Panel
Illustration 1 g03393731
(1) MCS Panel
(2) "EMERGENCY STOP" switch
(3) "OVERSPEED SHUTDOWN" lamp
(4) "HIGH TEMPERATURE SHUTDOWN" lamp
(5) "LOW OIL PRESSURE SHUTDOWN" lamp
(6) "SHUTDOWN OVERRIDE" lamp
(7) "MAINTENANCE RESET" switch
Illustration 2 g03388563
MCS Control Panel
(8) "ALARM" indicator
(9) Display
(10) "LOG"
(11) "VIEW"
(12) Menu key for UP
(13) "INDICATOR LAMP" for the power status of the controller
(14) "INDICATOR LAMP" for the status of the controller
(15) "ALARM" indicator
(16) Menu key for RIGHT
(17) Menu key for SELECT
(18) "LAMP TEST" switch
(19) Menu key for DOWN
(20) "BACK" key
(21) Menu key for LEFT
(22) Indicator lamp for control in remote mode
(23) "MODE" key
(24) "INDICATOR LAMP" for the status of the generator
(25) "ENGINE OPERATING"indicator
(26) "STOP" key (reset)
(27) "START" key
(28) "JUMP" key
(29) "INFO" key Controls for MCS Panel
"ALARM" indicator (8) - A flashing LED indicates that alarms that have not been acknowledged are still present. A fixed LED indicates that all alarms are acknowledged. A red LED indicates shutdown. A green LED is for an alarm.Display Area (9) - The display area shows information about the generator set."LOG" key (10) - This key shifts the display to the three lower lines in order to show the event and a list of alarms. The list holds 100 events. These events are erased when the main unit is switched off. Press the "LOG" key down for 5 seconds to display details of the Engine Information Center (EIC) logged events."VIEW" key (11) - Enter a menu number selection. All settings have a specific number. The "VIEW" key enables the user to select any setting. The "VIEW" key enables the user to display any setting without navigating through all of the menus.Menu Key for "UP" (12) - This key increases the value of the selected set point in the setting menus. This key is also used for scrolling to the second line that displays the values for the generator in the display for daily use."INDICATOR LAMP" for the power status of the controller (13) - This lamp indicates the power status of the controller."INDICATOR LAMP" for the status of the controller (14) - This lamp indicates that the unit is running a self-check and the unit is functioning properly."INDICATOR LAMP" for the alarm inhibit (15) - This lamp indicates that the "inhibit input" is on.Menu Key for "RIGHT" (16) - This key moves the cursor to the right in order to maneuver in the menus."SEL" key (17) - This key is used to select the function that has been chosen. The function that has been chosen is the underlined selection in the lower line of the display."LAMP TEST" switch (18) - The lamp test switch is used to test indicators on the control panel.Menu Key for "DOWN" (19) - This key decreases the value of the selected set point in the setting menus. This key is also used for scrolling to the second line that displays the values for the generator in the display for daily use."BACK" key (20) - The "BACK" key jumps one step backward in the menu to previous display or to the entry screen.Menu Key
Illustration 1 g03393731
(1) MCS Panel
(2) "EMERGENCY STOP" switch
(3) "OVERSPEED SHUTDOWN" lamp
(4) "HIGH TEMPERATURE SHUTDOWN" lamp
(5) "LOW OIL PRESSURE SHUTDOWN" lamp
(6) "SHUTDOWN OVERRIDE" lamp
(7) "MAINTENANCE RESET" switch
Illustration 2 g03388563
MCS Control Panel
(8) "ALARM" indicator
(9) Display
(10) "LOG"
(11) "VIEW"
(12) Menu key for UP
(13) "INDICATOR LAMP" for the power status of the controller
(14) "INDICATOR LAMP" for the status of the controller
(15) "ALARM" indicator
(16) Menu key for RIGHT
(17) Menu key for SELECT
(18) "LAMP TEST" switch
(19) Menu key for DOWN
(20) "BACK" key
(21) Menu key for LEFT
(22) Indicator lamp for control in remote mode
(23) "MODE" key
(24) "INDICATOR LAMP" for the status of the generator
(25) "ENGINE OPERATING"indicator
(26) "STOP" key (reset)
(27) "START" key
(28) "JUMP" key
(29) "INFO" key Controls for MCS Panel
"ALARM" indicator (8) - A flashing LED indicates that alarms that have not been acknowledged are still present. A fixed LED indicates that all alarms are acknowledged. A red LED indicates shutdown. A green LED is for an alarm.Display Area (9) - The display area shows information about the generator set."LOG" key (10) - This key shifts the display to the three lower lines in order to show the event and a list of alarms. The list holds 100 events. These events are erased when the main unit is switched off. Press the "LOG" key down for 5 seconds to display details of the Engine Information Center (EIC) logged events."VIEW" key (11) - Enter a menu number selection. All settings have a specific number. The "VIEW" key enables the user to select any setting. The "VIEW" key enables the user to display any setting without navigating through all of the menus.Menu Key for "UP" (12) - This key increases the value of the selected set point in the setting menus. This key is also used for scrolling to the second line that displays the values for the generator in the display for daily use."INDICATOR LAMP" for the power status of the controller (13) - This lamp indicates the power status of the controller."INDICATOR LAMP" for the status of the controller (14) - This lamp indicates that the unit is running a self-check and the unit is functioning properly."INDICATOR LAMP" for the alarm inhibit (15) - This lamp indicates that the "inhibit input" is on.Menu Key for "RIGHT" (16) - This key moves the cursor to the right in order to maneuver in the menus."SEL" key (17) - This key is used to select the function that has been chosen. The function that has been chosen is the underlined selection in the lower line of the display."LAMP TEST" switch (18) - The lamp test switch is used to test indicators on the control panel.Menu Key for "DOWN" (19) - This key decreases the value of the selected set point in the setting menus. This key is also used for scrolling to the second line that displays the values for the generator in the display for daily use."BACK" key (20) - The "BACK" key jumps one step backward in the menu to previous display or to the entry screen.Menu Key
Caterpillar parts catalog:
Parts channel Caterpillar catalog:
4517348
CHANNEL AS
Caterpillar
Caterpillar
4517347
CHANNEL AS
Caterpillar
Caterpillar
4517346
CHANNEL AS
Caterpillar
Caterpillar
4411773
CHANNEL AS
Caterpillar
Caterpillar
4411772
CHANNEL
Caterpillar
Caterpillar
4411752
CHANNEL AS
Caterpillar
Caterpillar
5149883
CHANNEL AS
Caterpillar
Caterpillar
5110442
CHANNEL AS
Caterpillar
Caterpillar
5110440
CHANNEL AS
Caterpillar
Caterpillar
5104374
CHANNEL AS
Caterpillar
Caterpillar
5104373
CHANNEL AS
Caterpillar
Caterpillar
4847589
CHANNEL AS
Caterpillar
Caterpillar