Removal Procedure
The Power Train Electric Drive System and the Accessory Power System will contain hazardous voltage levels during machine operation and for a period of time after machine shutdown.Do not remove any covers that will expose energized electrical components while the engine is operating. Do not remove any covers that will expose the energized electrical components while the components remain energized following an engine shutdown.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the engine is operating.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the components remain energized following an engine shutdown.Always perform the safe shutdown and de-energizing procedure before performing electrical service on the Power Train Electric Drive System or the Accessory Power System.Failure to follow these instructions could result in personal injury or death.
The two top compartments on the front of the Inverter Cabinet contain low voltage control components. All of the other compartments in the cabinet contain high voltage components. The "Electrical Shutdown and Voltage Discharge" procedure must be performed before any of the high voltage compartments are entered.
Prepare the machine for maintenance. Refer to Operation and Maintenance Manual , "Prepare the Machine for Maintenance".
Shutdown and de-energizing the machine. Refer to Operation and Maintenance Manual, "Electrical Shutdown and Voltage Discharge".
Illustration 1 g03795101
Remove cover assembly (1).
Illustration 2 g03795103
Disconnect harness assemblies (2) from each of the bulk capacitors (3). Note: Using a jumper harness, short bulk capacitors (3) by connecting the positive lead and negative lead in series.
Remove mounting bolts (4). Remove bulk capacitor assembly (5).
Repeat Step 4 and Step 5 for the remaining bulk capacitor assembly (5). Installation Procedure
Install capacitor assembly (5) in the reverse order of removal.
The Power Train Electric Drive System and the Accessory Power System will contain hazardous voltage levels during machine operation and for a period of time after machine shutdown.Do not remove any covers that will expose energized electrical components while the engine is operating. Do not remove any covers that will expose the energized electrical components while the components remain energized following an engine shutdown.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the engine is operating.Do not perform any type of electrical maintenance on the orange hazardous voltage conductors, the power train components or the accessory power system components while the components remain energized following an engine shutdown.Always perform the safe shutdown and de-energizing procedure before performing electrical service on the Power Train Electric Drive System or the Accessory Power System.Failure to follow these instructions could result in personal injury or death.
The two top compartments on the front of the Inverter Cabinet contain low voltage control components. All of the other compartments in the cabinet contain high voltage components. The "Electrical Shutdown and Voltage Discharge" procedure must be performed before any of the high voltage compartments are entered.
Prepare the machine for maintenance. Refer to Operation and Maintenance Manual , "Prepare the Machine for Maintenance".
Shutdown and de-energizing the machine. Refer to Operation and Maintenance Manual, "Electrical Shutdown and Voltage Discharge".
Illustration 1 g03795101
Remove cover assembly (1).
Illustration 2 g03795103
Disconnect harness assemblies (2) from each of the bulk capacitors (3). Note: Using a jumper harness, short bulk capacitors (3) by connecting the positive lead and negative lead in series.
Remove mounting bolts (4). Remove bulk capacitor assembly (5).
Repeat Step 4 and Step 5 for the remaining bulk capacitor assembly (5). Installation Procedure
Install capacitor assembly (5) in the reverse order of removal.
Caterpillar parts catalog:
Parts channel Caterpillar catalog:
3K5079
CHANNEL ASSEM (RH)
16, 950, 955K, 977H, D4D, D9G
16, 950, 955K, 977H, D4D, D9G
3K5080
CHANNEL ASSEM (LH)
16, 950, 955K, 977H, D4D, D9G
16, 950, 955K, 977H, D4D, D9G
8D1129
CHANNEL ASSEM.
140, 14E
140, 14E
5D4917
CHANNEL
12E, 12F, 14E
12E, 12F, 14E
2D6233
CHANNEL
12E
12E
2D6232
CHANNEL
12E
12E
2D6231
CHANNEL
12E
12E
2G2874
CHANNEL ASSEM.
120G, 130G
120G, 130G
2G2873
CHANNEL ASSEM.
120G, 130G
120G, 130G
2G3323
CHANNEL ASSEM.
120G, 130G
120G, 130G
7N3703
CHANNEL
16G
16G
7N3710
CHANNEL
16G
16G