Illustration 1 g01619517
Partial SchematicThe conditions that are listed below may cause the angle sensor to not power up:
Display
Fuse
Circuit Breaker
Main Power Relay
Wiring
Faulty Angle SensorTest Step 1. VERIFY THAT THE DISPLAY WILL POWER UP
Ensure that the disconnect switch for the battery and the key start switch are in the ON position.
Turn on the display.Expected Result:The display turns on.Results:
YES - The display turns on. Proceed to Test Step 2.
NO - The display does not turn on.Repair: Perform the procedure that is listed in the Troubleshooting, "Electrical Power Supply (Display)" section of this manual.STOPTest Step 2. VERIFY THAT THE ANGLE SENSOR POWERS UP
Press the "Menu" key.
Use the arrow keys in order to select the "Diagnostic" menu. Press the "OK" key.
Verify that all of the sensors that are shown on the "Diagnostics" menu are shown as "connected".Expected Result:The angle sensor is connected.Results:
YES - The sensor is present and connected.Repair: The problem was caused because the display was turned off. Return the machine to service.STOP
NO - The sensor is not connected. Proceed to Test Step 3.Test Step 3. CHECK THE POWER TO THE ANGLE SENSORS
Place the disconnect switch and the key start switch in the ON position.
Disconnect the harness connector from the angle sensor.
Measure the voltage between pin "A" and pin "F" on the harness connector for the angle sensor.Expected Result:The measured voltage is approximately machine voltage.Results:
YES - The measured voltage is approximately machine voltage. The angle sensor has failed.Repair: Replace the angle sensor. Return the machine to service.STOP
NO - The voltage is not approximately machine voltage. Proceed to Test Step 4.Test Step 4. CHECK THE FUSE
Disconnect the 10 amp "AccuGrade" fuse (Fuse 17) from the fuse panel.
Check the resistance across the two contacts of the fuse. Expected Result:The resistance measurement is less than 1.0 ohm.Results:
YES - The resistance measurement is less than 1.0 ohm. The fuse is not open. Proceed to Test Step 5.
NO - The resistance measurement is greater than 1.0 ohms. The fuse is open.Repair: Replace the fuse. Return the machine to operation.STOPTest Step 5. CHECK THE CIRCUIT BREAKERAn open "Main Breaker" circuit will disrupt power to the display.
Place the key start switch and the disconnect switch in the OFF position.
Check for an open at the 80 amp "Main Breaker" circuit breaker.Expected Result:The 80 amp "Main Breaker" circuit breaker is open.Results:
YES - The circuit breaker is open.Repair: Reset the open circuit breaker. Resume the operation of the machine.STOP
NO - The 80 amp "Main Breaker" circuit breaker is not open. Proceed to Test Step 6.Test Step 6. CHECK THE MAIN POWER RELAY
Place the disconnect switch and the key start switch in the ON position. The engine should be off.
Measure the voltage between wire (CBL-PU) on the main power relay and frame ground.Expected Result:The voltage measurement is between 18 VDC and 32 VDC.Results:
YES - The voltage measurement is between 18 VDC and 32 VDC. Proceed to Test Step 7.
NO - The voltage measurement is not between 18 VDC and 32 VDC.Repair: Verify that between 18 VDC and 32 VDC is present at wire (CBL-RD)
Cat SIS web machinery list:
Parts clamp Caterpillar catalog:
8I0842
CLAMP
AP-1000, AP-1050
AP-1000, AP-1050
5E9374
CLAMP AS
AP-1000, AP-1050, AP-650B, AP-800, AP-800C, AP-800D, BG-225B, BG-225C, CB-434, CB-434B, CB-534B, CB-614, PR-750B
AP-1000, AP-1050, AP-650B, AP-800, AP-800C, AP-800D, BG-225B, BG-225C, CB-434, CB-434B, CB-534B, CB-614, PR-750B
8T4606
CLAMP AS
10 FT, 10-20B, 8-16B, AP-1000, AP-1050, AP-800, AP-800C, AP-800D, BG-225B, CB-434, CB-534, CB-544, CB-545, CB-614, CP-433B, CP-563, CS-323, CS-551, CS-583, PR-450, RM-250C, RR-250, RR-250B, SS-250
10 FT, 10-20B, 8-16B, AP-1000, AP-1050, AP-800, AP-800C, AP-800D, BG-225B, CB-434, CB-534, CB-544, CB-545, CB-614, CP-433B, CP-563, CS-323, CS-551, CS-583, PR-450, RM-250C, RR-250, RR-250B, SS-250
5E9698
CLAMP-HOSE
AP-1000, AP-1050, AP-1055B, AP-800, BG-2455C, BG-245C, CP-433C, CP-563, CS-323C, CS-431C, CS-433C, CS-531, CS-531C, CS-533, CS-533C, CS-563C, CS-573C, CS-583, CS-583C, PM-465
AP-1000, AP-1050, AP-1055B, AP-800, BG-2455C, BG-245C, CP-433C, CP-563, CS-323C, CS-431C, CS-433C, CS-531, CS-531C, CS-533, CS-533C, CS-563C, CS-573C, CS-583, CS-583C, PM-465
5E9375
CLAMP
10 FT, 10-20B, 10B, 8 FT, 8-16B, AP-1000, AP-1000B, AP-1050, AP-1055D, AP-1200, AP-650B, AP-655C, AP-800, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, BG-2455C, BG-2455D, BG-260D, CB-314, CB-534, CB-5...
10 FT, 10-20B, 10B, 8 FT, 8-16B, AP-1000, AP-1000B, AP-1050, AP-1055D, AP-1200, AP-650B, AP-655C, AP-800, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, BG-2455C, BG-2455D, BG-260D, CB-314, CB-534, CB-5...
5E0114
CLAMP
10 FT, 10-20B, 8-16B, AP-1000, AP-1000B, AP-1050, AP-650B, AP-800, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, CB-434, CP-433B, CP-563, CS-531, CS-533, CS-583
10 FT, 10-20B, 8-16B, AP-1000, AP-1000B, AP-1050, AP-650B, AP-800, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, CB-434, CP-433B, CP-563, CS-531, CS-533, CS-583
7R0206
CLAMP
AP-1000, AP-1000B, AP-1050, AP-1055B, AP-1055D, AP-900B, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D
AP-1000, AP-1000B, AP-1050, AP-1055B, AP-1055D, AP-900B, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D
1046863
CLAMP
AP-1000, AP-1000B, AP-1050, AP-1055B, AP-1055D, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D, BG1000E...
AP-1000, AP-1000B, AP-1050, AP-1055B, AP-1055D, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D, BG1000E...
1051379
CLAMP AS
AP-1000, AP-1000B, AP-1050, AP-1055B, AP-650B, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, BG-2455C, BG-245C
AP-1000, AP-1000B, AP-1050, AP-1055B, AP-650B, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, BG-2455C, BG-245C
7R7270
CLAMP
AP-1000, AP-1050, AP-1200
AP-1000, AP-1050, AP-1200
6R3744
CLAMP AS
AP-1000, AP-1000B, AP-1050, AP-650B, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, CB-434
AP-1000, AP-1000B, AP-1050, AP-650B, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, CB-434
8C1020
CLAMP AS
AP-1000, AP-1000B, AP-1050, AP-650B, AP-800, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, CB-544, CB-545, CB-614, CP-433B, CP-563, CS-531, CS-533, CS-583, PR-450, PR-750B, RM-250C, RR-250, RR-250B, SS...
AP-1000, AP-1000B, AP-1050, AP-650B, AP-800, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, CB-544, CB-545, CB-614, CP-433B, CP-563, CS-531, CS-533, CS-583, PR-450, PR-750B, RM-250C, RR-250, RR-250B, SS...