Illustration 1 g02359438
Schematic of the Transmission Solenoid 2
This diagnostic code is associated with the Transmission Solenoid 2. The FMI 03 means that the ECM has determined that the voltage is above normal.The possible causes of the diagnostic code are listed:
The solenoid has failed.
The solenoid energizer circuit of the solenoid valve is shorted to the +battery circuit.
The ECM has failed. The ECM failing is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1402 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active, the ECM will turn off the current to the failed solenoid.Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE +BATTERY CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J1-62 (wire 752-YL(Yellow)) to all sources of +battery. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-62 (752-YL(Yellow)) and the +battery circuit.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 1402 FMI 03 is active. Expected Result:The CID 1402 FMI 03 is active.Results:
YES - The CID 1402 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 1402 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
Caterpillar parts catalog:
Parts clamp Caterpillar catalog:
3H7253
CLAMP
D9E
D9E
8G7757
CLAMP
D8L
D8L
7T6982
CLAMP AS
D7H
D7H
3T6679
CLAMP
D10N, D11N, D8L, D9L, D9N
D10N, D11N, D8L, D9L, D9N
8N4403
CLAMP
D10
D10
8N0573
CLAMP
D9L
D9L
2M3767
CLAMP
D9E
D9E
9H9621
CLAMP
D8H
D8H
2W1071
CLAMP
D8L
D8L
9W8103
CLAMP AS
D9N
D9N
9W8102
CLAMP
D9N
D9N