5V4313 CLEANER BAR AS Caterpillar parts
815B
Rating:
Alternative (cross code) number:
CA5V4313
5V-4313
5V4313
CA5V4313
5V-4313
5V4313
Weight: 530 pounds 240 kg.
SOIL COMPACTOR,
Compatible equipment models: 5V4313:
Information:
Illustration 1 g01419349
Schematic of the auxiliary lever #2 position sensorThis diagnostic code is associated with the auxiliary lever #2 position sensor. The FMI 08 diagnostic means that the ECM has determined that the signal frequency or the signal pulse width is not within the expected range. The sensor is a PWM sensor that operates at a frequency of approximately 500 hertz. The sensor has an operating duty cycle of 5% to 95%. The possible causes of this diagnostic code are listed below:
The sensor has failed.
Intermittent connections or poor connections
Mechanical devices are loose.
The ECM has failed. This is unlikely.Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all of the circuit connections are clean. Verify that all of the circuit connections are secure. Verify that all of the circuit connections are in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2205 FMI 08 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure. Test Step 1. CHECK FOR POWER AT THE SENSOR.
Do not disconnect the harness connector from the sensor.
At the back of the harness connector for the sensor, insert a multimeter probe along contact 1 (wire 709-OR) for the voltage supply.
At the back of the harness connector for the sensor, insert a multimeter probe along contact 2 (wire J764-BR) for the ground.
Turn the key start switch and the disconnect switch to the ON position.
Measure the voltage from contact 1 (wire 709-OR) to contact 2 (wire J764-BR).Expected Result:The voltage is 10 0.5 DCV.Results:
OK - The voltage is 10 0.5 DCV. Proceed to Test Step 3.
NOT OK - The voltage is not 10 0.5 DCV. The circuit is open. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK THE SIGNAL CIRCUIT OF THE SENSOR.
Turn the key start switch and the disconnect switch to the OFF position.
At the back of the harness connector for the sensor, remove the multimeter probe from contact 1 and insert the probe along the signal wire 3 (wire J948-PK).
The other multimeter probe remains at the ground wire contact 2 (wire J764-BR).
Turn the disconnect switch and the key start switch to the ON position.
Monitor the signal of the sensor with the multimeter.
Without disconnecting the sensor or the hardware that is associated with the sensor from the machine, take the sensor through the full operating range of the sensor.Expected Result:
Caterpillar parts catalog:
Parts cleaner Caterpillar catalog:
8R3836
CLEANER BAR GP
815B, 815F
815B, 815F
8R3827
CLEANER BAR GP
815B, 815F
815B, 815F
8R3849
CLEANER BAR GP
815B, 815F
815B, 815F
1532710
CLEANER BAR GP
815B, 815F, 815F II
815B, 815F, 815F II
8R3830
CLEANER BAR AS
815B, 815F
815B, 815F
8R3850
CLEANER BAR AS
815B, 815F
815B, 815F
2153681
CLEANER AS
824H, 826G II, 826H
824H, 826G II, 826H
1388441
CLEANER-BRAKE
322C, OEMS
322C, OEMS
2223117
CLEANER-BRAKE
1090, 1190T, 1290T, 2290, 2491, 322B L, 322C, 324D FM, 325B L, 325C L, 511, 522B, 532, OEMS, TK711, TK722, TK732
1090, 1190T, 1290T, 2290, 2491, 322B L, 322C, 324D FM, 325B L, 325C L, 511, 522B, 532, OEMS, TK711, TK722, TK732
1205569
CLEANER, AIR
CB-614
CB-614
1206244
CLEANER, AIR
CB-614
CB-614
04003659
Cleaner assy.
Caterpillar
Caterpillar
1215466
CLEANER BAR AS
816F, 816F II
816F, 816F II
8R3850
CLEANER BAR AS
815B, 815F
815B, 815F
8R3830
CLEANER BAR AS
815B, 815F
815B, 815F