7X9670 CLEVIS Caterpillar parts
Rating:
Alternative (cross code) number:
CA7X9670
7X-9670
7X9670
CA7X9670
7X-9670
7X9670
Weight: 0.06 pounds 0 kg.
Information:
Illustration 1 g00895101
Schematic of the clutch 3 solenoid (reverse)
This diagnostic code is associated with the clutch 3 solenoid (reverse). The FMI 05 means that the ECM has determined that the current of the solenoid is below normal. The possible causes of this diagnostic code are listed below:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1403 FMI 05 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid with the active diagnostic code from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire 754-BU(Blue)) to contact 2 (wire X750-OR(Orange)).
Observe the status of the CID 1403 FMI 05. Expected Result:The CID 1403 FMI 05 remains active. The FMI has not changed and the "05" is still active.Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Repeat this Test Step "CHECK THE SOLENOID" in order to verify the solenoid failure. Replace the solenoid. Verify that the new solenoid corrects the problem.STOPTest Step 2. CHECK THE HARNESS FOR AN OPEN.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector(s) from the ECM.
The jumper wire that was installed in the previous Test Step remains in place.
At the machine harness connector, measure the resistance from signal contact J1-66 (wire 754-BU(Blue)) to contact J1-55 (wire X750-OR(Orange)). Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in wire 754-BU(Blue) or in wire X750-OR(Orange) of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts of the harness connectors and clean the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 1403 FMI 05. Expected Result:The CID 1403 FMI 05 is active. Results:
YES - The CID 1403 FMI 05 is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the
Parts clevis Caterpillar catalog:
7X4729
CLEVIS ROD
Caterpillar
Caterpillar
7U2602
CLEVIS
Caterpillar
Caterpillar
7R6937
CLEVIS EYE
Caterpillar
Caterpillar
7R6909
CLEVIS
Caterpillar
Caterpillar
7R0430
CLEVIS PIN
Caterpillar
Caterpillar
7F6754
CLEVIS
Caterpillar
Caterpillar
8C0376
CLEVIS
Caterpillar
Caterpillar
8C0495
CLEVIS-ROD
Caterpillar
Caterpillar
8C1065
CLEVIS
Caterpillar
Caterpillar
8C1296
CLEVIS
Caterpillar
Caterpillar
8C1803
CLEVIS
Caterpillar
Caterpillar
8C1850
CLEVIS
Caterpillar
Caterpillar