3T4283 COLLAR Caterpillar parts
215, 931B, 933, 933C, AP-1055D, AP-650B, AP-655D, BG-225C, BG-245C, BG655D, D3C III, D3G, D3K XL, D4C III, D4G, D4K XL, PR-450, PR-450C
Rating:
Alternative (cross code) number:
CA3T4283
3T-4283
3T4283
CA3T4283
3T-4283
3T4283
Weight: 2 pounds 1 kg.
ASPHALT PAVER, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$44.19
10 Nov 2022
US: Florida-Parts-Z
6S3486 - END Collar - Roller D3 3T4283 fits Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
Compatible equipment models: 3T4283:
Information:
Recommended Periodic Insulation Tests
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
Part Number Part Name Quantity
300-8648 Insulation Testing Gp 1
Illustration 1 g01388839
PMPE Generator Wiring Diagram
(CR1-C6) Diodes
(CR7) Varistor
(L1) Exciter Stator
(L2) Exciter Rotor
(L3) Main Rotor
(L4) Main Stator
(L5) PMG Stator
(PM) Permanent Magnet
(RFA) Rotating Field Assembly
(CT1) Optional Voltage Droop Transformer
(T0, T1, T2, T3, T7, T8, T9) Generator terminals
Periodically, use an insulation tester to check the insulation resistance of the generators main stator winding. The frequency of this test is determined by the generators environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every 3 months.
The generator set is not protected from the elements in an enclosed area. Test every 3 months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every 12 months (minimum).
The generator set has not been run under load for 3 months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must be used whenever salt is present or high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above 1 megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for the Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Disconnect "T0" from ground.
Disconnect the sensing lead wires for the regulator. This may be accomplished by unplugging the harness connectors.
Disconnect the PT leads of the load share module.
Connect the insulation testers Black lead to ground.
Connect the insulation testers RED lead to "T0".
Set the voltage to the
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
Part Number Part Name Quantity
300-8648 Insulation Testing Gp 1
Illustration 1 g01388839
PMPE Generator Wiring Diagram
(CR1-C6) Diodes
(CR7) Varistor
(L1) Exciter Stator
(L2) Exciter Rotor
(L3) Main Rotor
(L4) Main Stator
(L5) PMG Stator
(PM) Permanent Magnet
(RFA) Rotating Field Assembly
(CT1) Optional Voltage Droop Transformer
(T0, T1, T2, T3, T7, T8, T9) Generator terminals
Periodically, use an insulation tester to check the insulation resistance of the generators main stator winding. The frequency of this test is determined by the generators environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every 3 months.
The generator set is not protected from the elements in an enclosed area. Test every 3 months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every 12 months (minimum).
The generator set has not been run under load for 3 months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must be used whenever salt is present or high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above 1 megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for the Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Disconnect "T0" from ground.
Disconnect the sensing lead wires for the regulator. This may be accomplished by unplugging the harness connectors.
Disconnect the PT leads of the load share module.
Connect the insulation testers Black lead to ground.
Connect the insulation testers RED lead to "T0".
Set the voltage to the
Cat SIS web machinery list:
Parts collar Caterpillar catalog:
9M8911
COLLAR-THRUST
16, 1693, 16G, 245, 245B, 3208, 3306, 3306B, 3406, 3406B, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3508, 3508C, 3512, 3516, 5130, 5230, 589, 615, 615C, 621E, 621F, 623E, 627B, 627E, 627F, 631D, ...
16, 1693, 16G, 245, 245B, 3208, 3306, 3306B, 3406, 3406B, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3508, 3508C, 3512, 3516, 5130, 5230, 589, 615, 615C, 621E, 621F, 623E, 627B, 627E, 627F, 631D, ...
1006532
COLLAR-ALTERNATOR
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 24H, 30/30, 3114, 3116...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 24H, 30/30, 3114, 3116...
1P1123
COLLAR-THRUST
120G, 130G, 215, 215B, 224, 225, 229D, 3304, 3304B, 3306, 3306B, 3406B, 515, 518, 518C, 525, 527, 926, 930, 936F, 950, 950B, 953, 963, CB-534, CS-643, D4E, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5H XL...
120G, 130G, 215, 215B, 224, 225, 229D, 3304, 3304B, 3306, 3306B, 3406B, 515, 518, 518C, 525, 527, 926, 930, 936F, 950, 950B, 953, 963, CB-534, CS-643, D4E, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5H XL...
5K7187
COLLAR
215, 225, 941, 943, D4D, D4E, D4E SR, PR-750B
215, 225, 941, 943, D4D, D4E, D4E SR, PR-750B
5D3546
COLLAR
117, 118, 127, 128, 12F, 14E, 30, 561C, 571G, 650B, 666, 666B, AP-1000B, AP-1055B, AP-1055D, AP-600D, AP-650B, AP-655C, AP-655D, AP1000E, AP1055E, AP555E, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D...
117, 118, 127, 128, 12F, 14E, 30, 561C, 571G, 650B, 666, 666B, AP-1000B, AP-1055B, AP-1055D, AP-600D, AP-650B, AP-655C, AP-655D, AP1000E, AP1055E, AP555E, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D...
3R6274
COLLAR
AP-1000B, AP-1055B, AP-1055D, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D, BG1000E, BG1055E, BG500E,...
AP-1000B, AP-1055B, AP-1055D, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-225C, BG-2455C, BG-2455D, BG-245C, BG-260D, BG1000E, BG1055E, BG500E,...
1324799
COLLAR
AP-800C, AP-800D, BG-225B, BG-225C
AP-800C, AP-800D, BG-225B, BG-225C
2848883
COLLAR-STOP
AP-1000B, AP-1055B, AP-650B, AP-655C, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, BG-245C
AP-1000B, AP-1055B, AP-650B, AP-655C, AP-800C, AP-800D, AP-900B, BG-225B, BG-225C, BG-245C
2848875
COLLAR
AP-1000B, AP-1055B, AP-1055D, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-225C, BG-2455D, BG-245C, BG-260D, BG1000E, BG1055E, BG500E, BG600D, B...
AP-1000B, AP-1055B, AP-1055D, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-225C, BG-2455D, BG-245C, BG-260D, BG1000E, BG1055E, BG500E, BG600D, B...
1469410
COLLAR
AP-600D, AP-655D, AP1000E, AP1055E, AP555E, BG1000E, BG1055E, BG500E, BG600D, BG655D, PM-201, PM-465, PM-565, PM-565B
AP-600D, AP-655D, AP1000E, AP1055E, AP555E, BG1000E, BG1055E, BG500E, BG600D, BG655D, PM-201, PM-465, PM-565, PM-565B
9N9186
COLLAR
PR-450
PR-450
0871528
COLLAR-CYLINDER
PR-450
PR-450
7G0418
COLLAR (Outer)
225, D6D, D6E, D6E SR, D6G SR
225, D6D, D6E, D6E SR, D6G SR
7G0417
COLLAR (Inner)
225, D6D, D6E SR
225, D6D, D6E SR
8N4512
COLLAR
215, 910, 931B, 943, 953, D3, D6D
215, 910, 931B, 943, 953, D3, D6D
7H4571
COLLAR ASSEM.
235, 572G, 572R, 572R II, 953C, 963B, 963C, 973, 973C, 973D, 977D, 977H, 977K, D5H, D5H XL, D6H, D6H XL, D6M, D6N, D6R, D6R II, D6R III, D7E, D7F, D7G, D7G2, D7H, D7R, D7R II, D7R XR, OEMS
235, 572G, 572R, 572R II, 953C, 963B, 963C, 973, 973C, 973D, 977D, 977H, 977K, D5H, D5H XL, D6H, D6H XL, D6M, D6N, D6R, D6R II, D6R III, D7E, D7F, D7G, D7G2, D7H, D7R, D7R II, D7R XR, OEMS
6S3486
COLLAR
215, 931, D3
215, 931, D3
5K7187
COLLAR
215, 225, 941, 943, D4D, D4E, D4E SR, PR-750B
215, 225, 941, 943, D4D, D4E, D4E SR, PR-750B
9T3417
COLLAR
225
225
9W2144
COLLAR-TRACK ROLLER
205B, 211B, 215B, 215D
205B, 211B, 215B, 215D
6W1451
COLLAR
215C, 225, 229, FB221
215C, 225, 229, FB221
0679539
COLLAR-LOWER
214, 224
214, 224
1W7545
COLLAR-FULL LOAD
215, 910, 931B, 943, D6D
215, 910, 931B, 943, D6D