4N4397 COLLAR-DRIVE SHAFT Caterpillar parts
3176B, 3176C, 3196, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3456, 768B, 769, C-10, C-12, C-15, C-16, C-9, C11, C12, C13, C15, C18, C7, C9, CX31-C13I, CX31-C15I, CX31-C...
Rating:
Alternative (cross code) number:
CA4N4397
4N-4397
4N4397
CA4N4397
4N-4397
4N4397
Weight: 0.05 pounds 0 kg.
Information:
ID
19.843
mm
MATERIAL THICKNESS
9.931
mm
OD
28.575
mm
GAS ENGINE, TRUCK,
Compatible equipment models: 4N4397:
INDUSTRIAL ENGINE
3176B
3176C
3196
3304
3306
3306B
3406
3406B
3406C
3406E
3408
3408C
3408E
3456
C-10
C-12
C-15
C-16
C-9
C11
C13
C15
C18
C7
C9
D320A
D342C
MARINE ENGINE
3176B
3176C
3196
3304
3304B
3306
3306B
3406
3406B
3406C
3406E
3408
3408C
C-12
C12
C15
C18
C9
D342
D353C
PETROLEUM PACKAGE
CX31-C13I
CX31-C15I
CX31-C18I
CX31-C9I
CX35-C18I
CX35-P800
TH35-C11I
TH35-C13I
TH35-C15I
PETROLEUM TRANSMISSION
TH31-E61
TRACTOR
768B
Information:
Loading of the Generator
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load. This allows the engine to work at the rated capacity. If one phase current exceeds the nameplate amperage, an electrical unbalance can result in an electrical overload and overheating.Allowable combinations of unbalanced loads are shown in Illustration 1. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g00627416
Allowable Combinations of Unbalanced Loads
Block Loading
Block loading is the instantaneous application of an electrical load to a generator set. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
Engine transient response
Voltage regulator response
Type of the voltage regulator
Altitude of operation of the generator set
Type of load (power factor for the load)
The percentage of load before the application of the block loadIf derating for the block load is required, refer to ISO 3046 Standards or SAE J1349 Standards. Also, reference Engine Data Sheet, LEKX4066, "Loading Transient Response" and Engine Data Sheet, LEKX4067, "Block and Transient Response". Note: ISO stands for International Standards Organization.Power Factor
The power factor represents the efficiency of the load. Power factor is the ratio of apparent power to total power. The power factor is expressed as a decimal. The power factor represents that portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors or other devices.In most applications, electric motors and transformers determine the power factor of the system. Induction motors usually have a 0.8 or smaller power factor. Incandescent lighting is a resistive load of about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor increases, the total current that is supplied to a constant power demand will decrease. For example, a 100 kW load at a 0.8 power factor will draw more current than a 100 kW load at 0.9 power factor. High power factor will result in full engine load at less than the rated amperage of the generator. A lower power factor increases the possibility of overloading the generator.Note: If no other power factor is specified, Caterpillar generators are designed for a 0.8 lagging power factor. Excitation Systems
Permanent Magnet Pilot Excited Generators
Note: The standard generator is designed with internal excitation. The PMPE generator is an option.Permanent Magnet Pilot Excited (PMPE) generators receive power for the voltage regulator from a pilot exciter, rather than the main armature.
When a generator is installed or reconnected, be sure that the total current in one phase does not exceed the nameplate rating. Each phase should carry the same load. This allows the engine to work at the rated capacity. If one phase current exceeds the nameplate amperage, an electrical unbalance can result in an electrical overload and overheating.Allowable combinations of unbalanced loads are shown in Illustration 1. When you operate with significant single-phase loads, the combinations of single-phase load and three-phase load may be used. Such combinations should be located below the line on the graph.
Illustration 1 g00627416
Allowable Combinations of Unbalanced Loads
Block Loading
Block loading is the instantaneous application of an electrical load to a generator set. This load may be anywhere from a moderate percentage of the rated load up to the rated load.The block loading capability of a generator set depends on the following factors.
Engine transient response
Voltage regulator response
Type of the voltage regulator
Altitude of operation of the generator set
Type of load (power factor for the load)
The percentage of load before the application of the block loadIf derating for the block load is required, refer to ISO 3046 Standards or SAE J1349 Standards. Also, reference Engine Data Sheet, LEKX4066, "Loading Transient Response" and Engine Data Sheet, LEKX4067, "Block and Transient Response". Note: ISO stands for International Standards Organization.Power Factor
The power factor represents the efficiency of the load. Power factor is the ratio of apparent power to total power. The power factor is expressed as a decimal. The power factor represents that portion of the current which is doing useful work. The portion of current which is not doing useful work is absorbed in maintaining the magnetic field in motors or other devices.In most applications, electric motors and transformers determine the power factor of the system. Induction motors usually have a 0.8 or smaller power factor. Incandescent lighting is a resistive load of about 1.0 power factor, or unity.The power factor of a system may be determined by a power factor meter or by calculations. Determine the power requirement in kW by multiplying the power factor by the kVA that is supplied to the system. As the power factor increases, the total current that is supplied to a constant power demand will decrease. For example, a 100 kW load at a 0.8 power factor will draw more current than a 100 kW load at 0.9 power factor. High power factor will result in full engine load at less than the rated amperage of the generator. A lower power factor increases the possibility of overloading the generator.Note: If no other power factor is specified, Caterpillar generators are designed for a 0.8 lagging power factor. Excitation Systems
Permanent Magnet Pilot Excited Generators
Note: The standard generator is designed with internal excitation. The PMPE generator is an option.Permanent Magnet Pilot Excited (PMPE) generators receive power for the voltage regulator from a pilot exciter, rather than the main armature.
Cat SIS web machinery list:
Parts collar Caterpillar catalog:
9M8911
COLLAR-THRUST
16, 1693, 16G, 245, 245B, 3208, 3306, 3306B, 3406, 3406B, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3508, 3508C, 3512, 3516, 5130, 5230, 589, 615, 615C, 621E, 621F, 623E, 627B, 627E, 627F, 631D, ...
16, 1693, 16G, 245, 245B, 3208, 3306, 3306B, 3406, 3406B, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412E, 3508, 3508C, 3512, 3516, 5130, 5230, 589, 615, 615C, 621E, 621F, 623E, 627B, 627E, 627F, 631D, ...
1006532
COLLAR-ALTERNATOR
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 24H, 30/30, 3114, 3116...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 16G, 16H NA, 24H, 30/30, 3114, 3116...
9S2261
COLLAR-SHAFT
120G, 12G, 130G, 140G, 14G, 160G, 16G, 235, 3114, 3116, 3208, 3304, 3306, 3306B, 3406, 3406B, 3408, 3412, 375, 578, 589, 594, 613C II, 621E, 623E, 627E, 627F, 631E, 637E, 651E, 657E, 815B, 826C, 950F,...
120G, 12G, 130G, 140G, 14G, 160G, 16G, 235, 3114, 3116, 3208, 3304, 3306, 3306B, 3406, 3406B, 3408, 3412, 375, 578, 589, 594, 613C II, 621E, 623E, 627E, 627F, 631E, 637E, 651E, 657E, 815B, 826C, 950F,...
9S2254
COLLAR-SHAFT
120G, 12G, 130G, 140G, 14G, 160G, 16G, 235, 3114, 3116, 3208, 3304, 3306, 3306B, 3406, 3406B, 3408, 3412, 375, 578, 589, 594, 613C II, 621E, 623E, 627E, 627F, 631E, 637E, 651E, 657E, 815B, 826C, 950F,...
120G, 12G, 130G, 140G, 14G, 160G, 16G, 235, 3114, 3116, 3208, 3304, 3306, 3306B, 3406, 3406B, 3408, 3412, 375, 578, 589, 594, 613C II, 621E, 623E, 627E, 627F, 631E, 637E, 651E, 657E, 815B, 826C, 950F,...
7N7795
COLLAR
120H, 120H NA, 12H, 12H NA, 135H, 135H NA, 140H, 140H NA, 140K, 14H NA, 160H, 160H NA, 160K, 215B, 235, 3116, 3126, 3126B, 3176B, 3176C, 3196, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E...
120H, 120H NA, 12H, 12H NA, 135H, 135H NA, 140H, 140H NA, 140K, 14H NA, 160H, 160H NA, 160K, 215B, 235, 3116, 3126, 3126B, 3176B, 3176C, 3196, 3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3406E...
5N9067
COLLAR
3114, 3116, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C15, ...
3114, 3116, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C15, ...
5N2904
COLLAR-SEAL
3408, 3408C, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C
3408, 3408C, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C
2S7289
COLLAR
1140, 1160, 16, 1673C, 1674, 1676, 1693, 225, 3160, 3304, 3306, 3408, 3412, 561C, 613, 621, 621R, 623, 627, 631C, 633C, 637D, 641B, 650B, 657B, 772, 814, 824B, 826B, 941, 943, 950, 955K, 966C, 977K, 9...
1140, 1160, 16, 1673C, 1674, 1676, 1693, 225, 3160, 3304, 3306, 3408, 3412, 561C, 613, 621, 621R, 623, 627, 631C, 633C, 637D, 641B, 650B, 657B, 772, 814, 824B, 826B, 941, 943, 950, 955K, 966C, 977K, 9...
9L6892
COLLAR-CHECK VALVE
245, 3406, 3408, 3412, 651E, 657E, 980C, 988B, 992C
245, 3406, 3408, 3412, 651E, 657E, 980C, 988B, 992C
1P1123
COLLAR-THRUST
120G, 130G, 215, 215B, 224, 225, 229D, 3304, 3304B, 3306, 3306B, 3406B, 515, 518, 518C, 525, 527, 926, 930, 936F, 950, 950B, 953, 963, CB-534, CS-643, D4E, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5H XL...
120G, 130G, 215, 215B, 224, 225, 229D, 3304, 3304B, 3306, 3306B, 3406B, 515, 518, 518C, 525, 527, 926, 930, 936F, 950, 950B, 953, 963, CB-534, CS-643, D4E, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5H XL...
8S8042
COLLAR
1673C, 16G, 245, 3306, 3406, 3406B, 3408, 3412, 627B, 983B, D6C, D7F, D8H, D8K
1673C, 16G, 245, 3306, 3406, 3406B, 3408, 3412, 627B, 983B, D6C, D7F, D8H, D8K
1K1265
COLLAR
769, 769C
769, 769C
7W0535
COLLAR-DRIVE SHAFT
3304, 3306, 3406, 3406B
3304, 3306, 3406, 3406B
5N9071
COLLAR
3114, 3116, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408B, 3412, 3412C, 3412D, 3412E, 3508, 3512, 3512B, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C15, C18, C27, C32, C9, G3306, G3406, G...
3114, 3116, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408B, 3412, 3412C, 3412D, 3412E, 3508, 3512, 3512B, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C15, C18, C27, C32, C9, G3306, G3406, G...
5N9070
COLLAR
3114, 3116, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, G3306, G3406, G3408, G340...
3114, 3116, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, G3306, G3406, G3408, G340...
5N9069
COLLAR
3116, 3126, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408B, 3412, 3412C, 3412D, 3412E, 3508, 3508C, 3512, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C32, G3508, G3516, PM3412, PM3516
3116, 3126, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408B, 3412, 3412C, 3412D, 3412E, 3508, 3508C, 3512, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C32, G3508, G3516, PM3412, PM3516
5N9068
COLLAR
3114, 3116, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408B, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, G3306, G3406, G350...
3114, 3116, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408B, 3412, 3412C, 3412D, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, G3306, G3406, G350...
5N9067
COLLAR
3114, 3116, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C15, ...
3114, 3116, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3408, 3408B, 3408C, 3412, 3412C, 3412D, 3412E, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, 3606, 3608, 3612, 3616, C15, ...
0897625
COLLAR
RT50, TH220B, TH330B, TH340B, TH350B, TH355B, TH62, TH63, TH82
RT50, TH220B, TH330B, TH340B, TH350B, TH355B, TH62, TH63, TH82
6I4208
COLLAR
3054, 3056, AP-800C, BG-225B, CB-534B, CB-534C, CB-535B, CP-433C, CS-431C, PS-200B, PS-300B, TH103, TH62, TH63, TH82, TH83
3054, 3056, AP-800C, BG-225B, CB-534B, CB-534C, CB-535B, CP-433C, CS-431C, PS-200B, PS-300B, TH103, TH62, TH63, TH82, TH83
9U0758
COLLAR
574, 65C, 65E, 75C, 75D, 75E, 85C, 85D, 85E, 95E
574, 65C, 65E, 75C, 75D, 75E, 85C, 85D, 85E, 95E
1128688
COLLAR
35, 45, 55
35, 45, 55
1285588
COLLAR
35, 45, 55
35, 45, 55
1219482
COLLAR
416B, 426B, 436B, 446B
416B, 426B, 436B, 446B