Information:
Table 1
Method for determining flow loss
Pump flow at 690 kPa (100 psi)
− Pump flow at 6900 kPa (1000 psi)
Flow loss
Table 2
Example of determining flow loss
217.6 L/min (57.5 US gpm)
− 196.8 L/min (52.0 US gpm)
20.8 L/min (5.5 US gpm) Flow loss is used as a measure of pump performance. Flow loss is expressed as a percentage of pump flow.
Table 3
Method of determining percent of flow loss
Flow loss (L/min or US gpm) × 100 = Percent of flow loss
Pump flow at 690 kPa (100 psi)
Table 4
Example of determining percent of flow loss
20.8 L (5.5 US gal) × 100 = 9.5%
217.6 L/min (57.5 US gpm) If the percent of flow loss is more than 10%, the pump performance is inadequate.Note: The values in the examples are not set values for any specific pump or for any specific pump condition. Refer to the Specifications for the specific machine.Test On The Machine
Install a 5P-3600 Hydraulic Flow Meter on the pressure side of the pump. Run the engine at high idle. Measure the pump flow at 690 kPa (100 psi), and at 6900 kPa (1000 psi). Use these values in the following formula (table 5).
Table 5
Method of determining percent of flow loss
Flow loss (L/min or US gpm) × 100 = Percent of flow loss
Pump flow at 690 kPa (100 psi) Test On The Bench
If the test bench can be run at 6900 kPa (1000 psi) and at full pump rpm, determine the percent of flow loss by using the following formula (table 6).
Table 6
Method of determining percent of flow loss
Flow loss (L/min or US gpm) × 100 = Percent of flow loss
Pump flow at 690 kPa (100 psi) If the test bench cannot be run at 6900 kPa (1000 psi) at full pump rpm, run the pump shaft at 1000 rpm. Measure the pump flow at 690 kPa (100 psi) and at 6900 kPa (1000 psi). Use these values in the top portion of the following formula (table 7). For the bottom part of the formula, run the pump shaft at 2000 rpm. Measure the pump flow at 690 kPa (100 psi).
Table 7
Pump flow at 690 kPa (100 psi)
− Pump flow at 6900 kPa (1000 psi) × 100 = Percent of flow loss
Pump flow at 690 kPa (100 psi) and at 2000 rpm
Caterpillar parts catalog:
Parts collet Caterpillar catalog:
8R3938
COLLET
988B, 988F, 988F II, R1600, R1600G, R1600H, R1700 II, R1700G, R2900, R2900G
988B, 988F, 988F II, R1600, R1600G, R1600H, R1700 II, R1700G, R2900, R2900G
8R3939
COLLET
988B, 988F, 988F II, R1600, R1600G, R1600H, R1700 II, R1700G, R2900, R2900G
988B, 988F, 988F II, R1600, R1600G, R1600H, R1700 II, R1700G, R2900, R2900G
8R4267
COLLET
988B, 988F, 988F II, AD30, AD45B, AD55, AD55B, AE40, AE40 II, R1600, R1600G, R1600H
988B, 988F, 988F II, AD30, AD45B, AD55, AD55B, AE40, AE40 II, R1600, R1600G, R1600H
8R4268
COLLET
988B, 988F, 988F II
988B, 988F, 988F II
8R4265
COLLET
988B, 988F, 988F II
988B, 988F, 988F II
8R3941
COLLET
988B, 988F, 988F II
988B, 988F, 988F II
8R3942
COLLET
988B, 988F, 988F II, R1600, R1600G, R1600H, R1700 II, R1700G, R2900, R2900G, R3000H
988B, 988F, 988F II, R1600, R1600G, R1600H, R1700 II, R1700G, R2900, R2900G, R3000H
8R4266
COLLET
988B, 988F, 988F II, AD30, AD45B, AD55, AD55B, AE40, AE40 II
988B, 988F, 988F II, AD30, AD45B, AD55, AD55B, AE40, AE40 II
7V1866
COLLET
988B
988B
3V0068
COLLET
988B
988B
8R4524
COLLET AS
988B
988B
9V5997
COLLET AS
988B
988B
4V2980
COLLET
988B
988B
4V2118
COLLET
988B
988B
7V3452
COLLET
988B
988B
7V3454
COLLET AS
988B
988B
5V8416
COLLET
988B
988B
9V6460
COLLET AS
980C, 980F
980C, 980F
1V8440
COLLET
980C, 980F, 980G
980C, 980F, 980G
8R3921
COLLET
980C, 980F, 980F II
980C, 980F, 980F II
8R3946
COLLET
980C, 980F, 980F II, 980G, 980G II, 980H, 980K, 980K HLG, R1300, R1300G, R1300G II
980C, 980F, 980F II, 980G, 980G II, 980H, 980K, 980K HLG, R1300, R1300G, R1300G II
9C9594
COLLET AS
988B
988B
8R4524
COLLET AS
988B
988B