4260198 CONDENSER Caterpillar parts
Rating:
Alternative (cross code) number:
CA4260198
426-0198
4260198
CA4260198
426-0198
4260198
Weight: 46 pounds 20 kg.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
19 Oct 2018
WIKA Instrument Corporation: WIKA Instrument
WIKA 4260198 Process Pressure Gauge, Dry-Filled, Stainless Steel 316L Wetted Parts, 4-1/2" Dial, 30"Hg-0-400 psi Range, +/- 0.5% Accuracy, 1/2" Male NPT Connection, Bottom Mount
Stainless steel 316L wetted parts for chloride corrosion resistance || Circular dial is enclosed in a thermoplastic case for increased durability in low temperature environments || Pressure ranges from 15 psi to 30,000 psi || Display accuracy of + or - 0.5 percent of span up to 20,000 psi and + or - 1.0 percent of span for pressure measures more than 20,000 psi || Male connection with 1/4" or 1/2" NPT rate
Stainless steel 316L wetted parts for chloride corrosion resistance || Circular dial is enclosed in a thermoplastic case for increased durability in low temperature environments || Pressure ranges from 15 psi to 30,000 psi || Display accuracy of + or - 0.5 percent of span up to 20,000 psi and + or - 1.0 percent of span for pressure measures more than 20,000 psi || Male connection with 1/4" or 1/2" NPT rate
Information:
Illustration 2 g01131276
Diagram for the installation of a connector plug (typical example)
(1) Electronic Control Module (ECM) connector
(2) Correctly inserted plug
(3) Incorrectly inserted plug Ensure that the sealing plugs are in place. If any of the plugs are missing, replace the plug. Ensure that the plugs are inserted correctly into the connector.
Illustration 3 g01131019
Seal for a three-pin connector (typical example)
Illustration 4 g01131165
Seal for the ECM connector (typical example)
Disconnect the suspect connector and inspect the connector seal. Ensure that the seal is in good condition. If necessary, replace the connector.Thoroughly inspect the connectors for evidence of moisture entry.Note: Some minor seal abrasion on connector seals is normal. Minor seal abrasion will not allow the entry of moisture.If moisture or corrosion is evident in the connector, the source of the moisture entry must be found. The source of the moisture entry must be repaired. If the source of the moisture entry is not repaired, the fault will recur. Simply drying the connector will not fix the fault. Check the following items for the possible moisture entry path:
Missing seals
Incorrectly installed seals
Nicks in exposed insulation
Improperly mated connectorsMoisture can also travel to a connector through the inside of a wire. If moisture is found in a connector, thoroughly check the connector harness for damage. Also check other connectors that share the harness for moisture.Check the Wires for Damage to the Insulation
Carefully inspect each wire for signs of abrasion, nicks, and cuts.Inspect the wires for the following conditions:
Exposed insulation
Rubbing of a wire against the engine
Rubbing of a wire against a sharp pointCheck all of the fasteners for the harness and the ECM in order to verify that the harness is correctly secured. Also check all of the fasteners in order to verify that the harness is not compressed. Pull back the harness sleeves in order to check for a flattened portion of wire. A fastener that has been overtightened flattens the harness. This damages the wires that are inside the harness.Inspect the Connector Terminals
Visually inspect each terminal in the connector. Verify that the terminals are not damaged. Verify that the terminals are correctly aligned in the connector and verify that the terminals are correctly located in the connector.Perform a Pull Test on Each Wire Terminal Connection
Illustration 5 g01131435
Receptacle lock wedge (typical example)
Ensure that the locking wedge for the connector is installed correctly. Terminals cannot be retained inside the connector if the locking wedge is not installed correctly.Perform the 45 N (10 lb) pull test on each wire. Each terminal and each connector should easily withstand 45 N (10 lb) of tension and each wire should remain in the connector body. This test checks whether the wire was correctly crimped in the terminal and whether the terminal was correctly inserted into the connector.Check Individual Pin Retention into the Socket
Illustration 6 g01131604
Diagram for testing pin retention (typical example)
Verify that the sockets provide good retention for the pins. Insert a new pin into each socket one at a time in order to check for a good grip on the pin by the socket.Check
Parts condenser Caterpillar catalog:
4174557
CONDENSER GP-
Caterpillar
Caterpillar
3975962
CONDENSER-A/C
Caterpillar
Caterpillar
3921610
CONDENSER GP-
Caterpillar
Caterpillar
3900100
CONDENSER
Caterpillar
Caterpillar
3728468
CONDENSER AS-A
Caterpillar
Caterpillar
3728451
CONDENSER AS-A
Caterpillar
Caterpillar
4566935
CONDENSER
Caterpillar
Caterpillar
4553175
CONDENSER GP
Caterpillar
Caterpillar
4523649
CONDENSER GP-
Caterpillar
Caterpillar
4455105
CONDENSER GP-
Caterpillar
Caterpillar
4389446
CONDENSER GP-
Caterpillar
Caterpillar
4338702
CONDENSER GP
Caterpillar
Caterpillar