4829955 CONDITIONER Caterpillar parts
Rating:
Alternative (cross code) number:
CA4829955
482-9955
4829955
CA4829955
482-9955
4829955
Weight: 50 pounds 22 kg.
Information:
Illustration 54 g06085937
(A) Indications shown by magnetic particle testing.
(B) Typical electromagnetic yoke.
(D) UV Lamp used in wet magnetic particle inspection process.
Illustration 55 g06003178
Pear Shaped Centrifuge Tube
Wet magnetic particles are fluorescent and are suspended in a vehicle in a given concentration that will allow application to the test surface by spraying.
Concentration:
The concentration of the suspended magnetic particles shall be as specified by the manufacturer and be checked by settling volume measurements.
Concentrations are determined by measuring the settling volume by using an ASTM pear shaped centrifuge tube with a 1 mL (0.034 oz) stem with 0.05 mL (0.0017 oz) 1.0 mL (0.034 oz) divisions, refer to Illustration 55. Before sampling, the suspension shall be thoroughly mixed to assure suspension of all particles, which could have settled. A 100 mL (3.40 oz) sample of the suspension shall be taken and allowed to settle for 30 minutes. The settling volume should be between 0.1 mL (0.0034 oz) and 0.25 mL (0.0085 oz) in a 100 mL (3.40 oz) sample.
Wet magnetic particles may be suspended in a low viscosity oil or conditioned water.
The oil shall have the following characteristics:
Low viscosity not to exceed 50 mSt (5.0 cSt) at any temperature at which the vehicle is to be used.
Low inherent fluorescence and be non-reactive.
The conditioning agents used in the conditioned water shall have the following characteristics:
Impart good wetting characteristics and good dispersion.
Minimize foaming and be non-corrosive.
Low viscosity shall not exceed a maximum viscosity of 50 mSt (5.0 cSt) at 38° C (100° F).
Non-fluorescent, non-reactive, and odorless.
Alkalinity shall not exceed a pH of 10.5.
Equipment should include a "U" shaped electromagnetic yoke made from highly permeable magnetic material, which has a coil wound around the yoke. This coil carries a magnetizing current to impose a localized longitudinal magnetic field into the part. The magnetizing force of the yoke is related to the electromagnetic strength and can be tested by determining the lifting power of a steel plate. The yoke shall have a lifting force of at least 4.5 kg (10 lbs).Procedure
Ensure surface to be inspected is dry and free from oil, grease, sand, loose rust, mil scale, paint, and any other contaminants.
Apply the magnetic field using the yoke against the surface in the area to be inspected.
For case hardened and ground surfaces:
Due to the sensitivity required to locate the grinding cracks, inspection of case hardened and ground surfaces require that the yoke is applied so that the magnetic field is 1.57 rad (90°) to the expected direction of the indications. Also, due to the increased sensitivity resulting when the yoke is energized, the yoke is not moved until the evaluation is completed in the first direction. An AC yoke shall be used.
Visually inspect for indications of discontinuities using the proper illumination.
Record the size and shape of any discontinuities found.Ultrasonic Testing (UT)
Refer to Tooling and Equipment Table 3 for part numbers.
All personnel involved in ultrasonic examinations shall be qualified to Level 2 in accordance to standards stated in Table 16.
Ultrasonic testing (UT) is a method of Non-Destructive Testing (NDT)
Parts conditioner Caterpillar catalog:
4741241
CONDITIONER
Caterpillar
Caterpillar
4741240
CONDITIONER
Caterpillar
Caterpillar
4741239
CONDITIONER
Caterpillar
Caterpillar
4735786
CONDITIONER
Caterpillar
Caterpillar
4698419
CONDITIONER
Caterpillar
Caterpillar
4684775
CONDITIONER
Caterpillar
Caterpillar
4886729
CONDITIONER AR
Caterpillar
Caterpillar
4885243
CONDITIONER GP
Caterpillar
Caterpillar
4872309
CONDITIONER
Caterpillar
Caterpillar
4866689
CONDITIONER AR
Caterpillar
Caterpillar
4843851
CONDITIONER GP
Caterpillar
Caterpillar
4843850
CONDITIONER
Caterpillar
Caterpillar