Table 1
Diagnostic Trouble Codes for DEF Pump Sensor Supply
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
3511-11 3482-11 Sensor Supply #3:Other Failure Mode High or low battery voltage supply has been detected on the 5V supply to the DEF pump.
Follow the troubleshooting procedure in order to identify the root cause of the problem.
Table 2
Required Tools
Tool Part Number Part Description Qty
A 372-5260 Test Kit 1
Illustration 1 g03811023Complete the procedure in the order in which the steps are listed.
Table 3
Troubleshooting Test Steps Values Results
1. Check the DEF Pump Pressure Sensor Supply Circuit for Excessive Voltage
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the Diesel Exhaust Fluid Controller (DCU).
B. Disconnect the Pump Electronic Tank Unit (PETU) harness from the DEF pump.
C. Verify that the harness connector is free of debris, free of corrosion, and securely connected.
D. Turn the keyswitch ON.
E. Measure the voltage between the 5V SUPPLY (Terminal 2) at the DEF pump connector and a known good ground source.
Supply voltage
Result: The voltage is greater than 5V.
Proceed to Test Step 3.
Result: The voltage is 5V or less.
Proceed to Test Step 2.
2. Check the DEF Pump Pressure Sensor Supply for a Short Circuit to Ground
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the DCU.
B. Disconnect the PETU wiring harness from the DEF pump.
C. Disconnect the 86 pin connector from the DCU.
D. Connect the 398-5056 Break-out Connector to the DEF pump connector.
Note: The 398-5056 Break-out Connector is included in the 372-5260 Test Kit.
Note: The 398-5056 Break-out Connector must be used to prevent damage to the DEF pump connector.
E. Measure the resistance between the 5V SUPPLY (Terminal 2 on the DEF pump connector) and a known good ground source.
Greater than 100k Ohms
Result: There was more than 100K ohms of resistance between the 5V SUPPLY and a ground source.
Proceed to Test Step 4.
Result: There was less than 100K ohms of resistance between the 5V SUPPLY and a ground source. A short circuit to ground has been detected.
Repair: Repair or replace the wiring harness.
Proceed to Test Step 4.
3. Check the DEF Pump Supply for a Pin-to Pin Short Circuit
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the DCU.
B. Disconnect the PETU wiring harness from the DEF pump.
C. Disconnect the 86 pin connector from the DCU.
D. Connect the 398-5063 Break-out Connector to the DCU connector.
Note: The 398-5063 Break-out Connector is included in the 372-5260 Test Kit.
Note: The 398-5063 Break-out Connector must be used to prevent damage to the DCU connector.
E. Measure the resistance between the 5V SUPPLY (Terminal 19 at the DCU connector) and all other pins in
Caterpillar parts catalog:
Parts connector Caterpillar catalog:
5162135
CONNECTOR
Caterpillar
Caterpillar
5162134
CONNECTOR
Caterpillar
Caterpillar
5162133
CONNECTOR
Caterpillar
Caterpillar
5161582
CONNECTOR
Caterpillar
Caterpillar
5161580
CONNECTOR
Caterpillar
Caterpillar
5160510
CONNECTOR AS
Caterpillar
Caterpillar
5172758
CONNECTOR
Caterpillar
Caterpillar
5165097
CONNECTOR AS
Caterpillar
Caterpillar
5162146
CONNECTOR
Caterpillar
Caterpillar
5162139
CONNECTOR
Caterpillar
Caterpillar
5162138
CONNECTOR
Caterpillar
Caterpillar
5162137
CONNECTOR
Caterpillar
Caterpillar