Schematic of the pressure sensor (fixed displacement pump oil)
Sales model 854G/992G
This diagnostic code is associated with the fixed displacement pump oil pressure sensor. The FMI 08 means that the ECM has determined that the signal frequency or the signal pulse width is not within the expected range.The output frequency of the pressure sensor is approximately 500 hertz. The duty cycle of the signal changes as the pressure changes.The signal may have one of the following characteristics:
Abnormal frequency
Abnormal pulse width
Abnormal period The possible causes of this condition are listed below:
The signal circuit is shorted to the +battery circuit or shorted to ground intermittently.
The signal circuit is open intermittently or the sensor is disconnected.
The sensor may have failed.
The ECM may have failed. This is unlikely.Note: This diagnostic code is usually caused by an intermittent condition. The diagnostic code is active and the diagnostic code is inactive over a period of time.Note: Ensure that there are no active CID 262 diagnostic codes for the 5 volt sensor power supply before performing this procedure. Ensure that CID 0767 FMI 08 diagnostic code is active. This test procedure may cause other diagnostic codes. Clear these diagnostic codes when the original diagnostic code has been corrected.Test Step 1. CHECK FOR POWER AT THE SENSOR
Disconnect the harness connector from the sensor.
Turn the key start switch and the disconnect switch to the ON position.
At the harness connector for the sensor, measure the voltage between contact A (wire 113-OR(Orange)) and contact B (wire J842-BK(Black)). Expected Result:The voltage is between 8 VDC and 32 VDC.Results:
OK - The voltage measurement is between 8 VDC and 32 VDC. Proceed to Test Step 3.
NOT OK - The voltage measurement is not between 8 VDC and 32 VDC. There is a problem in the supply circuit. Proceed to Test Step 2.Test Step 2. CHECK THE POWER SUPPLY AT THE ECMThe machine harness connectors J1 and J2 are connected to the ECM for this step.
Turn the key start switch to the ON position.
At the machine harness connector of the ECM, insert the 7X-1710 Multimeter Probe into the back of the connectors at contacts J1-10 (wire M912-BU(Blue)) and J2-19 (wire J842-BK(Black)). Measure the voltage. Expected Result:The voltage measurement is between 8 VDC and 32 VDC.Results:
OK - The voltage measurement is between 8 VDC and 32 VDC. The ECM power supply is correct.Repair: There is a problem in the sensor circuit in the machine harness. Either the supply wire M912-BU(Blue) or the return wire J842-BK(Black) has a bad connection or an open in the machine harness. Refer to the complete machine Electrical Schematic. Check the resistance of each circuit from the ECM connection to the sensor connection in order to determine the circuit that is open. Then, check each wire from connection point to connection point for an open. Repair the machine harness or replace the machine harness.STOP
NOT OK - The voltage measurement is not between 8 VDC and 32 VDC. The ECM may have failed.Repair: Perform this procedure again. If the correct
Caterpillar parts catalog:
Parts console Caterpillar catalog:
3949501
CONSOLE
Caterpillar
Caterpillar
3949500
CONSOLE
Caterpillar
Caterpillar
3899292
CONSOLE GP-OPERATOR
Caterpillar
Caterpillar
3899291
CONSOLE GP-OPERATOR
Caterpillar
Caterpillar
3899290
CONSOLE GP-OPERATOR
Caterpillar
Caterpillar
4805305
CONSOLE
Caterpillar
Caterpillar
3952935
CONSOLE
Caterpillar
Caterpillar
3952934
CONSOLE
Caterpillar
Caterpillar
3949547
CONSOLE-REAR
Caterpillar
Caterpillar
3949546
CONSOLE AS-FRONT
Caterpillar
Caterpillar
3949515
CONSOLE-FRONT
Caterpillar
Caterpillar
3949514
CONSOLE-FRONT
Caterpillar
Caterpillar