Schematic of the Solenoid Valve (Brake Air Supply)This diagnostic code is associated with the brake air supply solenoid valve. This diagnostic code is recorded when the ECM reads the voltage of the solenoid valve circuit as being above normal. The signal circuit is shorted to the +battery circuit.The possible causes of this failure are listed:
The energized circuit for the solenoid valve is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: Ensure that the diagnostic code is active.Test Step 1. CHECK THE SIGNAL CIRCUIT FOR A SHORT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the solenoid valve.
Disconnect the machine harness connectors J1 and J2 from the ECM.
At machine harness connector J1, measure the resistance from the solenoid signal contact J1-6 (wire R734-WH) to all other J1 and J2 connector contacts. Expected Result:Each resistance should be greater than 5000 ohms.Results:
YES - Each resistance is greater than 5000 ohms. The machine harness is correct. Proceed to test step 2.
NO - There is a short in the machine harness. Repair: The short is between the signal contact J1-6 (wire R734-WH) and the circuit with the lowest resistance measurement. Repair the machine harness or replace the machine harness. Stop.Test Step 2. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Clear all inactive diagnostic codes.
Operate the machine.
Stop the machine.
Check if the diagnostic code for the solenoid valve is present.Expected Result:The diagnostic code for the solenoid valve is NO longer present.Results:
YES - The diagnostic code is NOT present. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation. Stop.
NO - The diagnostic code has not been corrected.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Also, recheck if the diagnostic code is active. If the cause of the diagnostic code is not found, replace the ECM. See Testing And Adjusting, "Electronic Control Module (ECM) - Replace". Stop.
Parts cont Caterpillar catalog:
4783974
CONT GP-
Caterpillar
Caterpillar
4783884
CONT AR-RIDE
Caterpillar
Caterpillar
4783882
CONT AR-RIDE
Caterpillar
Caterpillar
4780040
CONT GP-
Caterpillar
Caterpillar
4779179
CONT GP-COM
Caterpillar
Caterpillar
4779178
CONT GP-COM
Caterpillar
Caterpillar
4797398
CONT GP
Caterpillar
Caterpillar
4795980
CONT-ANTI SKID
Caterpillar
Caterpillar
4793019
CONT GP
Caterpillar
Caterpillar
4791892
CONT GP
Caterpillar
Caterpillar
4791890
CONT GP
Caterpillar
Caterpillar
4791889
CONT GP
Caterpillar
Caterpillar