1869790 CONTROL GP-HANDLE Caterpillar parts
R1300, R1300G, R1600, R1600G, R1600H, R1700G, R2900, R2900G, R3000H
Rating:
Alternative (cross code) number:
CA1869790
186-9790
1869790
CA1869790
186-9790
1869790
Weight: 0.50 pounds 0 kg.
LOAD HAUL DUMP,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 1869790:
Information:
Aftertreatment Air System
Illustration 16 g06257978
(1) ARD body
(2) ARD head
(3) Line for the combustion air
(4) Exhaust from turbocharger
(5) Exhaust manifold
(6) Turbocharger
(7) Compressed air to aftercooler
(8) ARD combustion air valve
(9) Combustion air inlet pressure sensor
(10) Exhaust air to DOC and DPFExhaust AirExhaust air flows from the turbine housing to the ARD body. The exhaust air then flows through the Diesel Oxidation Catalyst (DOC) and the DPF. The exhaust air then exits through the SCR.Combustion AirThe air used to supply the ARD head is taken from the turbocharger compressor outlet. The pressure of this air is measured at the inlet to the ARD combustion air valve by the combustion air inlet pressure sensor. The air is then metered by the ARD combustion air valve. The ARD combustion air valve contains a DC motor and analog position sensor. The aftertreatment ECM controls the ARD combustion air valve by sending it a desired opening position. The ARD combustion air valve moves the desired amount and the new valve position is transmitted back to the aftertreatment ECM.
Illustration 17 g06257980
(8) ARD combustion air valve
(11) Electronic Control Module (ECM)
(12) Desired position command
(13) Actual valve position dataOnce the air has been metered by the ARD combustion air valve, the air enters the ARD head. The ARD head contains a swirling plate that is designed to agitate the air that is being mixed with the fuel. This agitated air allows for a precise burn of the air/fuel mixture.Cooling System
Two lines circulate coolant in the ARD head. The coolant is used to extend the life of the O-ring for the ARD nozzle.Diesel Particulate Filter (DPF) System
Illustration 18 g06257983
(1) DPF inlet and delta pressure sensors
(2) DPF inlet temperature sensorThe DPF system contains two types of filter media. The first filter media that exhaust gas is exposed to is the Diesel Oxidation Catalyst (DOC). This filter is a flow through style filter. The DOC is contained in the inlet section of the DPF cannister. The DOC filter contains platinum and palladium. The minerals aid in oxidizing hydrocarbons, carbon monoxide, and soluble organic fractions as the exhaust gas flows through the filter. The inlet section of the DPF cannister contains a temperature sensor, a pressure tap for the DPF inlet pressure sensor, and a DPF delta pressure sensor. All three of these components are before the DOC. The purposes of these components are:DPF inlet temperature sensorThe DPF inlet temperature sensor measures the temperature entering the DPF cannister assembly. This temperature is used to control the ARD fuel and ARD air flow to maintain a desired DPF inlet temperature during regeneration.DPF Delta Pressure sensorThe delta pressure sensor is also used to measure soot collected in the DPF. The delta pressure sensor is measuring the pressure drop across the DPF. Since the delta pressure sensor is measuring flow resistance across the DPF, the sensor will also detect ash loading.DPF Inlet Pressure sensorUsed to measure the backpressure being generated by the DPF.Once the exhaust gas flows through the DOC, the exhaust gas enters the DPF. The DPF is
Illustration 16 g06257978
(1) ARD body
(2) ARD head
(3) Line for the combustion air
(4) Exhaust from turbocharger
(5) Exhaust manifold
(6) Turbocharger
(7) Compressed air to aftercooler
(8) ARD combustion air valve
(9) Combustion air inlet pressure sensor
(10) Exhaust air to DOC and DPFExhaust AirExhaust air flows from the turbine housing to the ARD body. The exhaust air then flows through the Diesel Oxidation Catalyst (DOC) and the DPF. The exhaust air then exits through the SCR.Combustion AirThe air used to supply the ARD head is taken from the turbocharger compressor outlet. The pressure of this air is measured at the inlet to the ARD combustion air valve by the combustion air inlet pressure sensor. The air is then metered by the ARD combustion air valve. The ARD combustion air valve contains a DC motor and analog position sensor. The aftertreatment ECM controls the ARD combustion air valve by sending it a desired opening position. The ARD combustion air valve moves the desired amount and the new valve position is transmitted back to the aftertreatment ECM.
Illustration 17 g06257980
(8) ARD combustion air valve
(11) Electronic Control Module (ECM)
(12) Desired position command
(13) Actual valve position dataOnce the air has been metered by the ARD combustion air valve, the air enters the ARD head. The ARD head contains a swirling plate that is designed to agitate the air that is being mixed with the fuel. This agitated air allows for a precise burn of the air/fuel mixture.Cooling System
Two lines circulate coolant in the ARD head. The coolant is used to extend the life of the O-ring for the ARD nozzle.Diesel Particulate Filter (DPF) System
Illustration 18 g06257983
(1) DPF inlet and delta pressure sensors
(2) DPF inlet temperature sensorThe DPF system contains two types of filter media. The first filter media that exhaust gas is exposed to is the Diesel Oxidation Catalyst (DOC). This filter is a flow through style filter. The DOC is contained in the inlet section of the DPF cannister. The DOC filter contains platinum and palladium. The minerals aid in oxidizing hydrocarbons, carbon monoxide, and soluble organic fractions as the exhaust gas flows through the filter. The inlet section of the DPF cannister contains a temperature sensor, a pressure tap for the DPF inlet pressure sensor, and a DPF delta pressure sensor. All three of these components are before the DOC. The purposes of these components are:DPF inlet temperature sensorThe DPF inlet temperature sensor measures the temperature entering the DPF cannister assembly. This temperature is used to control the ARD fuel and ARD air flow to maintain a desired DPF inlet temperature during regeneration.DPF Delta Pressure sensorThe delta pressure sensor is also used to measure soot collected in the DPF. The delta pressure sensor is measuring the pressure drop across the DPF. Since the delta pressure sensor is measuring flow resistance across the DPF, the sensor will also detect ash loading.DPF Inlet Pressure sensorUsed to measure the backpressure being generated by the DPF.Once the exhaust gas flows through the DOC, the exhaust gas enters the DPF. The DPF is
Caterpillar parts catalog:
Parts control Caterpillar catalog:
1729389
CONTROL GP-UNPROGRAMMED
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 24H, 525B, 535B, 545, 561N, 572R...
120H, 120H ES, 120H NA, 120K, 120K 2, 12H, 12H ES, 12H NA, 12K, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 143H, 160H, 160H ES, 160H NA, 160K, 163H, 163H NA, 24H, 525B, 535B, 545, 561N, 572R...
3E5370
CONTROL GP-ELECTRONIC
3116, 325, 325 L, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5080, 5130, 777B, 784B, 785, 785B, 789, 789B, 793, 793B, 814F, 815F, 816F, 844, 950F, 950F II, 960F, 966F, 966F II, 970F, 980F, 980F II...
3116, 325, 325 L, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5080, 5130, 777B, 784B, 785, 785B, 789, 789B, 793, 793B, 814F, 815F, 816F, 844, 950F, 950F II, 960F, 966F, 966F II, 970F, 980F, 980F II...
3E0461
CONTROL GP-ELECTRONIC
69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 784B, 785B, 789B, 793B, 793C, 936F, 963, 963B, 973, 992C, 994, 994D, AD40, AD45, AE40, AE40 II, R1300, R1600, R1700 II, R1700G, R2900
69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 784B, 785B, 789B, 793B, 793C, 936F, 963, 963B, 973, 992C, 994, 994D, AD40, AD45, AE40, AE40 II, R1300, R1600, R1700 II, R1700G, R2900
3114716
CONTROL BOX
AD45, AE40 II, R1300
AD45, AE40 II, R1300
9EP2229
CONTROL GP-PILOT VALVE
R1300, R1600
R1300, R1600
3004722
CONTROL BOX
R1300
R1300
1869850
CONTROL GP-INTERFACE
R1300, R1600
R1300, R1600
2286150
CONTROL BOX AS
R1600
R1600
1869756
CONTROL BOX AS
R1600
R1600
1868928
CONTROL UNIT - ELECT.
R1700 II, R2900
R1700 II, R2900
3496103
CONTROL GP-UNPROGRAMMED
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797F
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797, 797F
2267385
CONTROL GP-AUTOMATIC LUBE
773D, 773E, 775E, 777D
773D, 773E, 775E, 777D
3010084
CONTROL GP-ELECTROHYDRAULIC
725, 730, 735, 740
725, 730, 735, 740
3010083
CONTROL GP-ELECTROHYDRAULIC
725, 730, 735, 740
725, 730, 735, 740
3630623
CONTROL GP-ELECTROHYDRAULIC
725, 730, 735, 740
725, 730, 735, 740
3630624
CONTROL GP-ELECTROHYDRAULIC
725C, 730C, 735B, 740B, 770, 770G, 770G OEM, 772, 772G, 772G OEM, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777F, 777G
725C, 730C, 735B, 740B, 770, 770G, 770G OEM, 772, 772G, 772G OEM, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777F, 777G
3043601
CONTROL GP-ELECTROHYDRAULIC
770, 772, 773F, 775F, 777F, 793F, 797F
770, 772, 773F, 775F, 777F, 793F, 797F
3043593
CONTROL GP-ELECTROHYDRAULIC
770, 772, 773F, 775F, 777F, 793F, 797F
770, 772, 773F, 775F, 777F, 793F, 797F
3577984
CONTROL AS-ELECTRONIC
R1700G, R3000H
R1700G, R3000H
1869752
CONTROL AS-TRANSMISSION
R1600, R1600G, R1700G, R2900, R2900G
R1600, R1600G, R1700G, R2900, R2900G