Table 1
Test Step     Voltage Reading     Voltage should be below this for 12 volt system     Voltage should be below this for 24 volt system    
4        
5        
4 minus 5         1.0 volt     2.0 volts    
6                
7        
6 minus 7         0.5 volt     1.0 volt    
8         0.5 volt     1.0 volt    
Measure the voltage between the alternator "B+" terminal and the alternator case ground.
Measure the voltage across the battery. Put the red lead on the + battery terminal, and put the black lead on the negative battery terminal. Step 5 should be completed as quickly as possible after Step 4.Expected Result: On a 12 volt system, the voltage should not be greater than the voltage that was recorded in Step 4. The voltage must also be within one volt. On 24 volt systems, the voltage is within 2 volts.Results:
YES - If the voltage in Step 4 is not more than 1 volt for 12 volt systems (2 volts for 24 volt systems) higher than the voltage in Step 5, this test is complete and the related wiring is correct at this time. Replace the alternator or go to Testing and Adjusting, "Component - Test" in order to test the internal parts of the alternator.
NO - If the voltage in Step 4 is more than 1 volt for 12 volt systems (2 volts for 24 volt systems) higher than the voltage in Step 5, there is high circuit resistance: corrosion, loose connections and damaged wiring. Continue to Step 6.
Check the voltage between the machine frame and the alternator "B+" terminal. Record the voltage.
Check the voltage between the machine frame and the + battery post. Step 7 should be completed as quickly as possible after Step 6. Expected Result: The voltage difference between Step 6 and Step 7 does not exceed 1 volt on 24 volt systems or 0.5 volts on 12 volt systems. Results:
YES - The voltage difference does not exceed the tolerance. The charging circuit is good. Go to Step 8.
NO - The voltage difference exceeds the tolerance. There is high resistance in the charging circuit: loose cables, corroded cables, damaged cables, faulty circuit breaker and faulty main relay. Correct the problem and retest the system.
Check the voltage between the negative battery post and the alternator case ground. Expected Result: The voltage does not exceed 1 volt on 24 volt systems or 0.5 volts on 12 volt systems. Results:
YES - The voltage difference does not exceed the tolerance. The ground circuit is good. There is an internal problem with the alternator. Replace the alternator or go to Testing and Adjusting, "Component - Test" in order to test the internal parts of the alternator.
NO - The voltage difference exceeds the tolerance. There is high resistance in the ground circuit: loose cables, corroded cables, loose alternator mounting
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts control Caterpillar catalog:
1892821
CONTROL GP-HEAT & AIR COND
308C, 314C, 321C
308C, 314C, 321C
2006630
CONTROL & MTG GP-JOYSTICK
308C, 311C, 314C
308C, 311C, 314C
2218963
CONTROL GP-UNPROGRAMMED
311C, 314C
311C, 314C
2299139
CONTROL AS
308C, 314C, 314D CR, 314D LCR, 321C, 321D LCR, 325C, 328D LCR
308C, 314C, 314D CR, 314D LCR, 321C, 321D LCR, 325C, 328D LCR
2014540
CONTROL GP-ELECTRONIC
314C, 321C
314C, 321C
3579966
CONTROL GP-DIFFERENTIAL LOCK
735B, 740B
735B, 740B
9EP0311
CONTROL & MTG GP-ELECTRONIC
R1700 II
R1700 II
4336377
CONTROL GP-PARKING BRAKE
901C, 902C, 903C
901C, 902C, 903C
1641500
CONTROL GP-HYDRAULIC HAND
416D, 420D
416D, 420D