1W0176 CONTROL GP-FUEL RATIO Caterpillar parts
3208
Rating:
Alternative (cross code) number:
CA1W0176
1W-0176
1W0176
CA1W0176
1W-0176
1W0176
Weight: 1 pounds 0 kg.
MARINE ENGINE,
Compatible equipment models: 1W0176:
Information:
Starting The Engine
1. Perform all before-starting inspections. Refer to "Before Starting" in the Engine Operation And Maintenance Guide. 2. Turn Engine Control Switch (ECS) (1) to the Manual Start position. The engine will start and run as long as the ECS (1) is in this position.3. When the engine starts, the engine fault circuits are now functional (armed). Should a fault occur, the engine will be automatically shut down. To restart the engine after being shutdown by a fault, first correct the fault condition, then turn ECS (1) to the Off-Reset position. Next start the engine as per step 2.4. After the engine starts and its systems have stabilized, apply the load.5. Regulate the frequency of the generator with the optional Governor Switch (GS) or the optional Speed Potentiometer (SP) (2) or the Manual Governor Control Lever on the engine.6. Regulate the voltage level of the generator with the voltage adjust rheostat (VAR) (3).Stopping The Engine
1. Remove the load from the engine.2. Turn the Engine Control Switch (ECS) to the Stop position. This will allow the engine to run for the preset, or programmed cool down time before shutdown. If high idle cool down at no load is not desired proceed to Step 3.3. Reduce engine speed to Low idle (approximately 2/3 the full load speed of 60 Hz units or 4/5 full load speed of 50 Hz units). Push down on the Governor Switch (GS) until low idle is achieved (for governors with electric motors), or turn down the Speed Potentiometer (SP) (for electronic governors). For manual governors move the Governor Control lever to the low idle position.4. While the engine is at low idle, measure the engine oil level. Oil level must be maintained between the Add and Full marks on the Engine Running side of the dipstick. For 3200 Series engines, the oil level cannot be measured with the engine running.5. Allow the engine to cool down while running at low idle (approximately five minutes). After the engine cools, turn the Engine Control Switch to the Off-Reset position.Emergency Stopping
The Emergency Stop Button is red in color and is used to shutdown the engine only in an emergency situation. It should not be used for normal engine stopping.Reset And Check Emergency Stop Switches
If the emergency stop switch was used to shut down the engine, it will be necessary to reset the switch. To reset the switch, pull out and rotate the button in the direction shown. If the emergency stop button was used to shutdown the engine it will be necessary to reset the air shutoff (if equipped).Before starting the engine, correct the problem that necessitated the emergency stop.
1. Perform all before-starting inspections. Refer to "Before Starting" in the Engine Operation And Maintenance Guide. 2. Turn Engine Control Switch (ECS) (1) to the Manual Start position. The engine will start and run as long as the ECS (1) is in this position.3. When the engine starts, the engine fault circuits are now functional (armed). Should a fault occur, the engine will be automatically shut down. To restart the engine after being shutdown by a fault, first correct the fault condition, then turn ECS (1) to the Off-Reset position. Next start the engine as per step 2.4. After the engine starts and its systems have stabilized, apply the load.5. Regulate the frequency of the generator with the optional Governor Switch (GS) or the optional Speed Potentiometer (SP) (2) or the Manual Governor Control Lever on the engine.6. Regulate the voltage level of the generator with the voltage adjust rheostat (VAR) (3).Stopping The Engine
1. Remove the load from the engine.2. Turn the Engine Control Switch (ECS) to the Stop position. This will allow the engine to run for the preset, or programmed cool down time before shutdown. If high idle cool down at no load is not desired proceed to Step 3.3. Reduce engine speed to Low idle (approximately 2/3 the full load speed of 60 Hz units or 4/5 full load speed of 50 Hz units). Push down on the Governor Switch (GS) until low idle is achieved (for governors with electric motors), or turn down the Speed Potentiometer (SP) (for electronic governors). For manual governors move the Governor Control lever to the low idle position.4. While the engine is at low idle, measure the engine oil level. Oil level must be maintained between the Add and Full marks on the Engine Running side of the dipstick. For 3200 Series engines, the oil level cannot be measured with the engine running.5. Allow the engine to cool down while running at low idle (approximately five minutes). After the engine cools, turn the Engine Control Switch to the Off-Reset position.Emergency Stopping
The Emergency Stop Button is red in color and is used to shutdown the engine only in an emergency situation. It should not be used for normal engine stopping.Reset And Check Emergency Stop Switches
If the emergency stop switch was used to shut down the engine, it will be necessary to reset the switch. To reset the switch, pull out and rotate the button in the direction shown. If the emergency stop button was used to shutdown the engine it will be necessary to reset the air shutoff (if equipped).Before starting the engine, correct the problem that necessitated the emergency stop.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts control Caterpillar catalog:
4N9399
CONTROL GP-GOVERNOR
225, 225D, 227, 229, 231D, 3208
225, 225D, 227, 229, 231D, 3208
9L6743
CONTROL GP-GOVERNOR
225D, 231D, 3208, 3406B, 613B, 613C, CB-614, CS-551, FB221, PR-1000, PS-500
225D, 231D, 3208, 3406B, 613B, 613C, CB-614, CS-551, FB221, PR-1000, PS-500
9N0425
CONTROL GP-GOVERNOR
3208, 3406
3208, 3406
1W9819
CONTROL GP-GOVERNOR
3208, 3406, 3406B, 3406C
3208, 3406, 3406B, 3406C
3T5000
CONTROL GP
3208
3208
2N1274
CONTROL (vernier)
3160, 3192, 3208, 7271
3160, 3192, 3208, 7271
1693025
CONTROL GP-JOYSTICK
554, 574
554, 574
1320449
CONTROL GP-MONITOR
3176B, 3406E, 3408B, 3412, 3508B, 3512B, 3516B
3176B, 3406E, 3408B, 3412, 3508B, 3512B, 3516B
1887726
CONTROL & MTG GP-ENGINE ELEK
938G II, 950G II, 962G II, D5N, D6N, IT38G II, IT62G II
938G II, 950G II, 962G II, D5N, D6N, IT38G II, IT62G II
2301240
CONTROL GP-PARKING BRAKE
938G II, 938H, IT38G II, IT38H
938G II, 938H, IT38G II, IT38H
1281203
CONTROL GP-FUEL
G3612, G3616
G3612, G3616
9N3362
CONTROL GP-FUEL RATIO
3408, 3412, 631D, 633D, 637D, 639D, 988B
3408, 3412, 631D, 633D, 637D, 639D, 988B
1258772
CONTROL GP-SERVICE BRAKE
RR-250B
RR-250B
3114043
CONTROL AR-AUXILIARY
320D FM RR
320D FM RR