2317928 CONTROL AS-TIMER Caterpillar parts
303, 304, 305
Rating:
Alternative (cross code) number:
CA2317928
231-7928
2317928
CA2317928
231-7928
2317928
Weight: 0.50 pounds 0 kg.
MINI HYD EXCAVATOR,
This part in 6 request:
Show.
This information for suppliers only!
2023-11-12
2023-01-14
2021-02-08
2020-11-25
2020-04-15
2018-07-26
Information:
"TOOL #1-TOOL #5" of System 5
Refer to Testing and Adjusting, "Work Tool Parameter - Program" for the Tool Control System for instructions on navigating the menus on the display.The table lists some of the parameters that should be verified for successful operation of the work tool. For this system, parameters that are not shown in the tables do not affect the operation of the work tool.
Table 1
Default Parameters for "TOOL #1 - Tool #5" for System 5    
Message Center (Line 3)    Default Values (Line 4)    Range of Values    Increment    Description of Parameter    
           
"TOOL# _001"     "0"             This is the default name of the work tool. The default name can be changed. Be sure to use a good descriptive name.    
"TOOL# _002"     "10"             Parameter 002 is Enabled when parameter 003 is ON.
When Parameter 002 is Enabled and the value of the engine speed dial indicator is Greater than the value of Parameter 002, the engine speed is determined by the value of Parameter 002 when the work tool is activated.
When Parameter 002 is Enabled and the value of the engine speed dial indicator is Less than the value of Parameter 002, the engine speed is determined by the value of the engine speed dial indicator when the work tool is activated.
Parameter 002 is Disabled when Parameter 003 is OFF.
When Parameter 002 is Disabled, the engine speed is determined by the value of the engine speed dial indicator.    
"TOOL# _003"     "ON"             When Parameter 003 is ON, Parameter 002 is Enabled.
When Parameter 003 is OFF, Parameter 002 is Disabled.    
"TOOL# _004"     "ENABLED"             "ENABLED" means that the ECM maintains the target rpm. "DISABLED" means that the ECM provides a constant torque to the pump. Constant torque is used primarily for applications with a magnet. A constant torque maintains a constant rpm for the engine and the generator.    Blank Table for System 5
Table 2
Default Parameters for "TOOL#____" for System 5    
Message Center (Line 3)    Default Values (Line 4)    Range of Values    Increment    Comments of Technician    
           
"001"                    
"002"                    
"003"                    
"004"                    
"005"                    
"101"                    
"102"                    
"103"                    
Refer to Testing and Adjusting, "Work Tool Parameter - Program" for the Tool Control System for instructions on navigating the menus on the display.The table lists some of the parameters that should be verified for successful operation of the work tool. For this system, parameters that are not shown in the tables do not affect the operation of the work tool.
Table 1
Default Parameters for "TOOL #1 - Tool #5" for System 5    
Message Center (Line 3)    Default Values (Line 4)    Range of Values    Increment    Description of Parameter    
           
"TOOL# _001"     "0"             This is the default name of the work tool. The default name can be changed. Be sure to use a good descriptive name.    
"TOOL# _002"     "10"             Parameter 002 is Enabled when parameter 003 is ON.
When Parameter 002 is Enabled and the value of the engine speed dial indicator is Greater than the value of Parameter 002, the engine speed is determined by the value of Parameter 002 when the work tool is activated.
When Parameter 002 is Enabled and the value of the engine speed dial indicator is Less than the value of Parameter 002, the engine speed is determined by the value of the engine speed dial indicator when the work tool is activated.
Parameter 002 is Disabled when Parameter 003 is OFF.
When Parameter 002 is Disabled, the engine speed is determined by the value of the engine speed dial indicator.    
"TOOL# _003"     "ON"             When Parameter 003 is ON, Parameter 002 is Enabled.
When Parameter 003 is OFF, Parameter 002 is Disabled.    
"TOOL# _004"     "ENABLED"             "ENABLED" means that the ECM maintains the target rpm. "DISABLED" means that the ECM provides a constant torque to the pump. Constant torque is used primarily for applications with a magnet. A constant torque maintains a constant rpm for the engine and the generator.    Blank Table for System 5
Table 2
Default Parameters for "TOOL#____" for System 5    
Message Center (Line 3)    Default Values (Line 4)    Range of Values    Increment    Comments of Technician    
           
"001"                    
"002"                    
"003"                    
"004"                    
"005"                    
"101"                    
"102"                    
"103"                    
Caterpillar parts catalog:
Parts control Caterpillar catalog:
2220045
CONTROL GP-HYDRAULIC PEDAL
303, 305
303, 305
2449583
CONTROL GP-BLADE
305, 305.5, 306
305, 305.5, 306
2093957
CONTROL AR-AUXILIARY
304, 305
304, 305
2221356
CONTROL GP-HYDRAULIC PEDAL
304, 305
304, 305
2001346
CONTROL GP-JOYSTICK
303, 304, 305
303, 304, 305
2001347
CONTROL GP-JOYSTICK
303, 304, 305
303, 304, 305
1754621
CONTROL AS-TIMER
303, 304, 305
303, 304, 305
1997933
CONTROL AS
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 312C, 315C, 318C, 319C, 320C FM, 320D, 320D FM, 320D FM RR, 322C, 322C FM, 324D FM, 324D FM LL, 325C FM, 325D FM, 330C FM, 330D FM, 511, 5...
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 312C, 315C, 318C, 319C, 320C FM, 320D, 320D FM, 320D FM RR, 322C, 322C FM, 324D FM, 324D FM LL, 325C FM, 325D FM, 330C FM, 330D FM, 511, 5...
1712545
CONTROL AS
312C, 315C, 318C, 322C, 322C FM, 325C, 325C FM, 330C FM, 330C L, 330C MH, TK1051
312C, 315C, 318C, 322C, 322C FM, 325C, 325C FM, 330C FM, 330C L, 330C MH, TK1051
2094919
CONTROL UNIT
312C
312C
1887681
CONTROL GP-WIPER
312C, 312D, 315C, 315D L, 318C, 319C, 319D, 320C, 320C FM, 320D, 320D FM, 322C, 322C FM, 323D L, 323D LN, 324D, 324D L, 324D LN, 325C, 325C FM, 325D, 325D L, 330C, 330C FM, 330C L, 330D, 330D L, 330D ...
312C, 312D, 315C, 315D L, 318C, 319C, 319D, 320C, 320C FM, 320D, 320D FM, 322C, 322C FM, 323D L, 323D LN, 324D, 324D L, 324D LN, 325C, 325C FM, 325D, 325D L, 330C, 330C FM, 330C L, 330D, 330D L, 330D ...
2014540
CONTROL GP-ELECTRONIC
314C, 321C
314C, 321C
2299139
CONTROL AS
308C, 314C, 314D CR, 314D LCR, 321C, 321D LCR, 325C, 328D LCR
308C, 314C, 314D CR, 314D LCR, 321C, 321D LCR, 325C, 328D LCR
2070117
CONTROL AS
308C, 314C, 321C
308C, 314C, 321C
2218963
CONTROL GP-UNPROGRAMMED
311C, 314C
311C, 314C