2470841 CONTROL GP-JOYSTICK Caterpillar parts
928HZ, 930G
Rating:
Alternative (cross code) number:
CA2470841
247-0841
2470841
CA2470841
247-0841
2470841
Weight: 6 pounds 3 kg.
WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
#US Replacement Part for Starter Solenoid Relay Fit Fits for Yamaaha Virago 500 750 920 XV500/750/920 1981-1983 relpart#2470841
Generic NOTE - Package included: 1 Set ONLY. Please check all carefully (photos and model) and make sure it will compatible with your original one.
Generic NOTE - Package included: 1 Set ONLY. Please check all carefully (photos and model) and make sure it will compatible with your original one.
Information:
Warning Levels
The ECM will assign a warning level to an active event code. Event codes are one of three levels. The level represents the severity of the abnormal condition. Each warning level requires a specific response from the operator. The warning levels and the required operator response are listed below.Warning Level 1
Warning level 1 alerts the operator that a machine system requires attention. The operator should check the system condition or perform maintenance on the involved system at the earliest possible time.Warning Level 2
Warning level 2 requires changing the operation of the machine or performing a maintenance procedure. Failure to correct the problem that caused this warning may damage the components that are involved in the system.Warning Level 3
Warning level 3 requires an immediate safe shutdown of the machine in order to avoid damage to the machine or injury to personnel. The problem that caused the event must be corrected before machine operation can resume.Indications and System Response
Caterpillar Electronic Technician (Cat ET) Service Tool
When an abnormal operating condition occurs, the status screen on the Cat ET indicates that there is an active event.Event codes are displayed on Cat ET in the following format:EXXXX Description of the codeThe "E" means that the code is an event code. The "XXXX" is a numeric identifier. The numeric identifier is followed by a description of the code.Active event codes are listed in ascending numerical order. The code with the lowest number is listed first. The active event code is removed from the list when the condition is no longer present.Logged Event Codes
Some event codes are logged in the ECM memory. Some event codes are active only. The logged event codes are listed in chronological order. The most recent code is listed first.A logged code is cleared from memory when one of the following conditions occur:
The service technician manually clears the code.
The code does not reoccur after a number of hours determined by each ECM.
A new code is logged and there are already ten logged codes in memory. In this case, the oldest logged code is cleared.Note: Always clear logged event codes after investigating and correcting the problem which generated the code.List of Event Codes
The following table lists event codes and the recommended responses. Use the Cat ET service tool in order to determine the event codes that are active or logged.
Table 1
List of Event Codes (EID)
EID Level Description Possible Cause and Recommended Response
861 1 Synchronized clock notification of manual synch required In a PL522 or 523 system using sync-clock and Product Link that is not the master ECM, the Product Link module will automatically sync to the master ECM hours if the difference is not greater than 50 hours. If the difference is greater than 50 hours, a diagnostic will be generated in Cat ET that indicates that a manual sync is required. In that instance, sync the hours. In Cat ET, use "Service/Synchronize Service Meter Hours".
630 2 Switched Sensor #1 trip condition is activated The PL522 or 523 has four additional
The ECM will assign a warning level to an active event code. Event codes are one of three levels. The level represents the severity of the abnormal condition. Each warning level requires a specific response from the operator. The warning levels and the required operator response are listed below.Warning Level 1
Warning level 1 alerts the operator that a machine system requires attention. The operator should check the system condition or perform maintenance on the involved system at the earliest possible time.Warning Level 2
Warning level 2 requires changing the operation of the machine or performing a maintenance procedure. Failure to correct the problem that caused this warning may damage the components that are involved in the system.Warning Level 3
Warning level 3 requires an immediate safe shutdown of the machine in order to avoid damage to the machine or injury to personnel. The problem that caused the event must be corrected before machine operation can resume.Indications and System Response
Caterpillar Electronic Technician (Cat ET) Service Tool
When an abnormal operating condition occurs, the status screen on the Cat ET indicates that there is an active event.Event codes are displayed on Cat ET in the following format:EXXXX Description of the codeThe "E" means that the code is an event code. The "XXXX" is a numeric identifier. The numeric identifier is followed by a description of the code.Active event codes are listed in ascending numerical order. The code with the lowest number is listed first. The active event code is removed from the list when the condition is no longer present.Logged Event Codes
Some event codes are logged in the ECM memory. Some event codes are active only. The logged event codes are listed in chronological order. The most recent code is listed first.A logged code is cleared from memory when one of the following conditions occur:
The service technician manually clears the code.
The code does not reoccur after a number of hours determined by each ECM.
A new code is logged and there are already ten logged codes in memory. In this case, the oldest logged code is cleared.Note: Always clear logged event codes after investigating and correcting the problem which generated the code.List of Event Codes
The following table lists event codes and the recommended responses. Use the Cat ET service tool in order to determine the event codes that are active or logged.
Table 1
List of Event Codes (EID)
EID Level Description Possible Cause and Recommended Response
861 1 Synchronized clock notification of manual synch required In a PL522 or 523 system using sync-clock and Product Link that is not the master ECM, the Product Link module will automatically sync to the master ECM hours if the difference is not greater than 50 hours. If the difference is greater than 50 hours, a diagnostic will be generated in Cat ET that indicates that a manual sync is required. In that instance, sync the hours. In Cat ET, use "Service/Synchronize Service Meter Hours".
630 2 Switched Sensor #1 trip condition is activated The PL522 or 523 has four additional
Caterpillar SIS machinery equipment:
Caterpillar SIS
930G Wheel Loader TWR00001-UP (MACHINE) POWERED BY 3056E Engine »
247-0841
CONTROL GP-JOYSTICK
930G Wheel Loader TFW00001-UP (MACHINE) POWERED BY 3056E Engine »
247-0841
CONTROL GP-JOYSTICK
928HZ 930H Wheel Loader CXK00001-02021 (MACHINE) POWERED BY C6.6 Engine »
247-0841
CONTROL GP-JOYSTICK
928Hz 930H Wheel Loader BYD00001-UP (MACHINE) POWERED BY C6.6 Engine »
247-0841
CONTROL GP-JOYSTICK
Caterpillar parts catalog:
Parts control Caterpillar catalog:
3E7844
CONTROL GP-LIFT KICKOUT
910E, 910G, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 938F, 938G, 938G II, 938H, 950G, 950G II, 962G, 962G II, 966G, 966G II, 972G, 972G II, 980G II, 980H, 988F, 988F II, 99...
910E, 910G, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 938F, 938G, 938G II, 938H, 950G, 950G II, 962G, 962G II, 966G, 966G II, 972G, 972G II, 980G II, 980H, 988F, 988F II, 99...
3E7843
CONTROL GP-BUCKET POSITIONER
416C, 420D, 420E, 426C, 428C, 428D, 428E, 430D, 430E, 432D, 432E, 434E, 436C, 438C, 438D, 442D, 442E, 444E, 902, 906, 908, 910E, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 93...
416C, 420D, 420E, 426C, 428C, 428D, 428E, 430D, 430E, 432D, 432E, 434E, 436C, 438C, 438D, 442D, 442E, 444E, 902, 906, 908, 910E, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 93...
2995841
CONTROL GP-TRANSMISSION
924G, 924GZ, 924H, 924HZ, 928H, 928HZ, 930G, 938G II, 938H, IT28G, IT38G II, IT38H
924G, 924GZ, 924H, 924HZ, 928H, 928HZ, 930G, 938G II, 938H, IT28G, IT38G II, IT38H
2531995
CONTROL GP-JOYSTICK
928HZ, 930G
928HZ, 930G
2211018
CONTROL GP-ENGINE ELECTRONIC
3054E, 3056E, 315C, 432E, 550B, 560B, 564, 574B, 924G, 924GZ, 930G, AP-655C, BB-760, CP-573E, CP-663E, CS-563E, CS-583E, CS-663E, CS-683E, IT28G, M313C, M315C, M316C, M318C, M318C MH, M322C, TH220B, T...
3054E, 3056E, 315C, 432E, 550B, 560B, 564, 574B, 924G, 924GZ, 930G, AP-655C, BB-760, CP-573E, CP-663E, CS-563E, CS-583E, CS-663E, CS-683E, IT28G, M313C, M315C, M316C, M318C, M318C MH, M322C, TH220B, T...
2851133
CONTROL GP-UNPROGRAMMED
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 140K, 140K 2, 140M, 140M 2, 14M, 160K, 160M, 160M 2, 16M, 2384C, 2470C, 2484C, 24M, 2570C, 2670C, 2864C, 311D LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2...
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 140K, 140K 2, 140M, 140M 2, 14M, 160K, 160M, 160M 2, 16M, 2384C, 2470C, 2484C, 24M, 2570C, 2670C, 2864C, 311D LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2...
3317539
CONTROL GP-UNPROGRAMMED
120M, 12M, 2470C, 311D LRR, 312D, 312D L, 313D, 314D CR, 314D LCR, 315D L, 318D L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 321D LCR, 323D L, 323D...
120M, 12M, 2470C, 311D LRR, 312D, 312D L, 313D, 314D CR, 314D LCR, 315D L, 318D L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 321D LCR, 323D L, 323D...
2863683
CONTROL GP-UNPROGRAMMED
120M, 12M, 320D, 320D FM, 320D GC, 323D L, 323D LN, 613G, 924H, 924HZ, 928HZ, 938H, 953D, 963D, AP-600D, AP-655D, BG600D, BG655D, C6.6, CP-56, CP-64, CP-76, CS-56B, CS-64, CS-74, D6K LGP, IT38H, M316D...
120M, 12M, 320D, 320D FM, 320D GC, 323D L, 323D LN, 613G, 924H, 924HZ, 928HZ, 938H, 953D, 963D, AP-600D, AP-655D, BG600D, BG655D, C6.6, CP-56, CP-64, CP-76, CS-56B, CS-64, CS-74, D6K LGP, IT38H, M316D...
2870524
CONTROL GP-HANDLE
924G, 924GZ, 924H, 924HZ, 928HZ, 930G, 938G II, 950G II, 962G II, 966G II, 972G II, IT28G, IT38G II
924G, 924GZ, 924H, 924HZ, 928HZ, 930G, 938G II, 950G II, 962G II, 966G II, 972G II, IT28G, IT38G II
2603025
CONTROL GP-HANDLE
928HZ, 930G
928HZ, 930G
2357500
CONTROL GP-WORK TOOL
928HZ, 930G
928HZ, 930G
2979334
CONTROL GP-PILOT OPERATED HYD
303.5C, 303.5D, 303C CR, 304C CR, 304D CR, 305.5D, 305C CR, 305D CR
303.5C, 303.5D, 303C CR, 304C CR, 304D CR, 305.5D, 305C CR, 305D CR
2979332
CONTROL GP-PILOT OPERATED HYD
303.5C, 303.5D, 303C CR, 304C CR, 304D CR, 305.5D, 305C CR, 305D CR
303.5C, 303.5D, 303C CR, 304C CR, 304D CR, 305.5D, 305C CR, 305D CR
2979333
CONTROL GP-JOYSTICK
303.5C, 303.5D, 303C CR, 304C CR, 304D CR, 305.5D, 305C CR, 305D CR
303.5C, 303.5D, 303C CR, 304C CR, 304D CR, 305.5D, 305C CR, 305D CR
2979330
CONTROL GP-JOYSTICK
303.5C, 303.5D, 303C CR, 304C CR, 304D CR, 305.5D, 305C CR, 305D CR
303.5C, 303.5D, 303C CR, 304C CR, 304D CR, 305.5D, 305C CR, 305D CR
3588808
CONTROL GP-XMSN & HOIST
725, 730, 735, 740
725, 730, 735, 740
2267469
CONTROL GP-ENGINE ELECTRONIC
C15, C18
C15, C18
2531995
CONTROL GP-JOYSTICK
928HZ, 930G
928HZ, 930G