2612207 CONTROL GP-TRANSMISSION Caterpillar parts
414E, 416D, 416E, 420D, 420E, 422E, 424B, 424D, 428D, 428E, 430D, 430E, 432D, 432E, 434E, 438D, 442D, 442E, 444E
Rating:
Alternative (cross code) number:
CA2612207
261-2207
2612207
CA2612207
261-2207
2612207
Weight: 2 pounds 0 kg.
BACKHOE LOADER,
You can buy:
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Transmission Shift Control 261-2207 174-6640 Fits for Caterpillar Backhoe Loader 414E 416E 420D Replace parts
GevLtty Part Name:Transmission Shift Control || Part Number: 261-2207 174-6640 || Application: Fits for Caterpillar Backhoe Loader 414E 416E 420D
GevLtty Part Name:Transmission Shift Control || Part Number: 261-2207 174-6640 || Application: Fits for Caterpillar Backhoe Loader 414E 416E 420D
Czomoizc 261-2207 174-6640 Transmission Control Group Compatible with Caterpillar CAT 414E 416D 416E 420D 420E 422E 424B 424D 428D 428E 430D 430E 432D 432E 434E 438D 442D 442E 444E Backhoe Loader
Czomoizc Part Name: Transmission Control Group || Part Number: 261-2207, 174-6640, 2612207, 1746640 || Compatible with Caterpillar CAT 414E 416D 416E 420D 420E 422E 424B 424D 428D 428E 430D 430E 432D 432E 434E 438D 442D 442E 444E Backhoe Loader || Package Includes: 1X Transmission Control Group, 261-2207, 174-6640 || This is a replacement Transmission Control Group, but the size is accurate and has been fully and strictly inspected before leaving the factory.Sold as shown in photos.
Czomoizc Part Name: Transmission Control Group || Part Number: 261-2207, 174-6640, 2612207, 1746640 || Compatible with Caterpillar CAT 414E 416D 416E 420D 420E 422E 424B 424D 428D 428E 430D 430E 432D 432E 434E 438D 442D 442E 444E Backhoe Loader || Package Includes: 1X Transmission Control Group, 261-2207, 174-6640 || This is a replacement Transmission Control Group, but the size is accurate and has been fully and strictly inspected before leaving the factory.Sold as shown in photos.
Zuide GP-Transmission Controll 174-6640 261-2207 2612208 For CAT Telehandler TH220B TH330B TH340B TH350B TH355B TH580B TH460B TH560B Engine 3054
Zuide Item name:GP-Transmission Controll || Part number:174-6640 261-2207 2612208 || For CAT Telehandler TH220B TH330B TH340B TH350B TH355B TH580B TH460B TH560B Engine 3054 || Please make sure that the product pictures and partnumbers are correct to avoid the parts you purchase not being suitable for your machine || If you are not sure that the parts are suitable for your machineplease take pictures of your originalparts for us and we will help you confirm
Zuide Item name:GP-Transmission Controll || Part number:174-6640 261-2207 2612208 || For CAT Telehandler TH220B TH330B TH340B TH350B TH355B TH580B TH460B TH560B Engine 3054 || Please make sure that the product pictures and partnumbers are correct to avoid the parts you purchase not being suitable for your machine || If you are not sure that the parts are suitable for your machineplease take pictures of your originalparts for us and we will help you confirm
This part in 10 request:
Show.
This information for suppliers only!
2023-06-28
2022-05-20
2021-11-23
2021-08-12
2020-06-17
2020-06-17
2020-06-17
2020-06-04
2019-09-16
2019-05-13
Compatible equipment models: 2612207:
Information:
General
The following troubleshooting guide is an aid in isolating trouble to the control box, actuator, plant wiring, or elsewhere. Troubleshooting beyond this level is recommended ONLY when a complete facility for control testing is available.
The control can be damaged with the wrong voltage. When replacing a control, check the power supply, battery, etc., for the correct voltage.
Troubleshooting Procedure
Table 6-1 is a general guide for isolating system problems. This guide assumes that the system wiring, soldering connections, switch and relay contacts, and input and output connections are correct and in good working order. Make the checks in the order indicated. Each system check assumes that the prior checks have been properly done.Control Test and Calibration
General
Do the following checks on the 701 Control. Then verify the functioning of set points and adjustments.1. Connect the Set Point Programmer to the control in accordance with the instructions in Chapter 4. Verify that correct voltage and polarity are applied to the control. Verify that the programmer does its power-up tests. Failure to do the power up test indicates either the control or Set Point Programmer has failed. Replace the control or Set Point Programmer.2. Press the SP key. The message "701 Speed Control P/N 5410-866" should appear. Failure indicates either the control or Set Point Programmer has failed. Replace the control or Set Point Programmer.3. Select Menu D. Step through the menu to the Self Test Result step. Verify that the displayed value is 49. If any other value is displayed, replace the control.4. Select Menu A. Verify that all set points are as recorded during installation. Repeat for Menus B, C, and 1. If any differences are found, change the set point(s) to the correct value. Press the "=" key. The message "Set Points Saved" should be displayed. Remove power from the control for at least 10 seconds. Verify correct values were retained during power down. Failure indicates the control has failed and should be replaced.Discrete Inputs
Do the following test to verify the function of the Discrete Inputs. Don't do these tests with the engine in operation. When reading the Set Point Programmer, be sure to update the display by pressing the up or down arrow.1. Close the Run/Stop contact or apply 24 Vdc between terminals 8(-) and 9(+) to select Run. Select Run/Stop Switch Status on Menu D. The status should be closed. If the value does not change from closed to open when the Run/Stop switch is opened, verify the voltage at the control terminals. If correct voltage is verified, the control has failed and should be replaced.2. Close the Idle/Rated contact or apply voltage to terminal 10(+). The Idle/Rated switch status should change from closed to open when the voltage is removed.3. Continue as
The following troubleshooting guide is an aid in isolating trouble to the control box, actuator, plant wiring, or elsewhere. Troubleshooting beyond this level is recommended ONLY when a complete facility for control testing is available.
The control can be damaged with the wrong voltage. When replacing a control, check the power supply, battery, etc., for the correct voltage.
Troubleshooting Procedure
Table 6-1 is a general guide for isolating system problems. This guide assumes that the system wiring, soldering connections, switch and relay contacts, and input and output connections are correct and in good working order. Make the checks in the order indicated. Each system check assumes that the prior checks have been properly done.Control Test and Calibration
General
Do the following checks on the 701 Control. Then verify the functioning of set points and adjustments.1. Connect the Set Point Programmer to the control in accordance with the instructions in Chapter 4. Verify that correct voltage and polarity are applied to the control. Verify that the programmer does its power-up tests. Failure to do the power up test indicates either the control or Set Point Programmer has failed. Replace the control or Set Point Programmer.2. Press the SP key. The message "701 Speed Control P/N 5410-866" should appear. Failure indicates either the control or Set Point Programmer has failed. Replace the control or Set Point Programmer.3. Select Menu D. Step through the menu to the Self Test Result step. Verify that the displayed value is 49. If any other value is displayed, replace the control.4. Select Menu A. Verify that all set points are as recorded during installation. Repeat for Menus B, C, and 1. If any differences are found, change the set point(s) to the correct value. Press the "=" key. The message "Set Points Saved" should be displayed. Remove power from the control for at least 10 seconds. Verify correct values were retained during power down. Failure indicates the control has failed and should be replaced.Discrete Inputs
Do the following test to verify the function of the Discrete Inputs. Don't do these tests with the engine in operation. When reading the Set Point Programmer, be sure to update the display by pressing the up or down arrow.1. Close the Run/Stop contact or apply 24 Vdc between terminals 8(-) and 9(+) to select Run. Select Run/Stop Switch Status on Menu D. The status should be closed. If the value does not change from closed to open when the Run/Stop switch is opened, verify the voltage at the control terminals. If correct voltage is verified, the control has failed and should be replaced.2. Close the Idle/Rated contact or apply voltage to terminal 10(+). The Idle/Rated switch status should change from closed to open when the voltage is removed.3. Continue as
Caterpillar parts catalog:
Parts control Caterpillar catalog:
3E7843
CONTROL GP-BUCKET POSITIONER
416C, 420D, 420E, 426C, 428C, 428D, 428E, 430D, 430E, 432D, 432E, 434E, 436C, 438C, 438D, 442D, 442E, 444E, 902, 906, 908, 910E, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 93...
416C, 420D, 420E, 426C, 428C, 428D, 428E, 430D, 430E, 432D, 432E, 434E, 436C, 438C, 438D, 442D, 442E, 444E, 902, 906, 908, 910E, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 93...
2160658
CONTROL GP-UNPROGRAMMED
216, 216B, 226B, 232B, 236, 236B, 242B, 247, 247B, 252B, 257B, 267, 267B, 268B, 420D, 424D, 430D, 432D, 442D
216, 216B, 226B, 232B, 236, 236B, 242B, 247, 247B, 252B, 257B, 267, 267B, 268B, 420D, 424D, 430D, 432D, 442D
1746640
CONTROL GP-TRANSMISSION
416D, 420D, 424D, 428D, 430D, 432D, 438D, 442D
416D, 420D, 424D, 428D, 430D, 432D, 438D, 442D
2612208
CONTROL GP-TRANSMISSION
416D, 420D, 420E, 424D, 428D, 430D, 430E, 432D, 432E, 434E, 438D, 442D, 442E, 444E, 446D, 450E, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
416D, 420D, 420E, 424D, 428D, 430D, 430E, 432D, 432E, 434E, 438D, 442D, 442E, 444E, 446D, 450E, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
2212375
CONTROL AS
325B L, 325C, 330B L, 330C MH, 345B, 345B II MH, 375 L, 416E, M325B, W330B, W345B II
325B L, 325C, 330B L, 330C MH, 345B, 345B II MH, 375 L, 416E, M325B, W330B, W345B II
1890881
CONTROL AS
414E, 416E, 416F, 420E, 420F, 422E, 422F, 428E, 428F, 430E, 430F, 432E, 432F, 434E, 434F, 442E, 444E, 444F, 450E, 450F
414E, 416E, 416F, 420E, 420F, 422E, 422F, 428E, 428F, 430E, 430F, 432E, 432F, 434E, 434F, 442E, 444E, 444F, 450E, 450F
2851133
CONTROL GP-UNPROGRAMMED
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 140K, 140K 2, 140M, 140M 2, 14M, 160K, 160M, 160M 2, 16M, 2384C, 2470C, 2484C, 24M, 2570C, 2670C, 2864C, 311D LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2...
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 140K, 140K 2, 140M, 140M 2, 14M, 160K, 160M, 160M 2, 16M, 2384C, 2470C, 2484C, 24M, 2570C, 2670C, 2864C, 311D LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2...
2503858
CONTROL GP-UNPROGRAMMED
432E, 434E, 773F, 775F, 777F, G3508, G3512, G3516
432E, 434E, 773F, 775F, 777F, G3508, G3512, G3516
4433876
CONTROL GP-TRANSMISSION HYD
420E, 430E, 432E, 434E
420E, 430E, 432E, 434E
2158307
CONTROL GP-HANDLE
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 247B, 247B3, 252B, 252B3, 257B, 257B3, 259B3, 267B, 432D, 442D
216B, 216B3, 226B, 226B3, 232B, 236B, 236B3, 242B, 242B3, 247B, 247B3, 252B, 252B3, 257B, 257B3, 259B3, 267B, 432D, 442D
3317540
CONTROL GP-UNPROGRAMMED
320D GC, 320D L, 323D L, 420E, 430E, 953D, 963D, C6.6, D3K XL, D4K XL, D5K LGP, D5R LGP, D6K, D6K LGP, D6K XL, D6N, PL61
320D GC, 320D L, 323D L, 420E, 430E, 953D, 963D, C6.6, D3K XL, D4K XL, D5K LGP, D5R LGP, D6K, D6K LGP, D6K XL, D6N, PL61
3985582
CONTROL GP-TRANSMISSION
424B, 424B HD
424B, 424B HD
2885759
CONTROL GP-HANDLE
TH580B
TH580B
2139800
CONTROL AS-ELECTRONIC
924GZ, IT28G, TH355B, TH460B, TH560B, TH580B, THP10 II
924GZ, IT28G, TH355B, TH460B, TH560B, TH580B, THP10 II
3966499
CONTROL GP-VOLTAGE
3054E, 3056E, 432E, C13, C15, C18, C7.1, C9.3, TH220B, TH330B, TH355B, TH460B, TH560B, TH580B
3054E, 3056E, 432E, C13, C15, C18, C7.1, C9.3, TH220B, TH330B, TH355B, TH460B, TH560B, TH580B
2086077
CONTROL GP-TRANSMISSION
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B
1741173
CONTROL GP-HANDLE
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B
2272005
CONTROL GP-HANDLE
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B
1890881
CONTROL AS
414E, 416E, 416F, 420E, 420F, 422E, 422F, 428E, 428F, 430E, 430F, 432E, 432F, 434E, 434F, 442E, 444E, 444F, 450E, 450F
414E, 416E, 416F, 420E, 420F, 422E, 422F, 428E, 428F, 430E, 430F, 432E, 432F, 434E, 434F, 442E, 444E, 444F, 450E, 450F
2212375
CONTROL AS
325B L, 325C, 330B L, 330C MH, 345B, 345B II MH, 375 L, 416E, M325B, W330B, W345B II
325B L, 325C, 330B L, 330C MH, 345B, 345B II MH, 375 L, 416E, M325B, W330B, W345B II
2166069
CONTROL GP-HYDRAULIC GENERATOR
325B L, 325C, 330B L, 330C MH, 345B II, 345B II MH, 365B, 375 L, 385C L MH, 416E, M325B, W330B, W345B II
325B L, 325C, 330B L, 330C MH, 345B II, 345B II MH, 365B, 375 L, 385C L MH, 416E, M325B, W330B, W345B II
2158308
CONTROL GP-HANDLE
226B, 226B3, 242B, 242B3, 247B, 257B, 257B3, 259B3, 267B, 268B, 420D, 430D, 442D
226B, 226B3, 242B, 242B3, 247B, 257B, 257B3, 259B3, 267B, 268B, 420D, 430D, 442D
2373656
CONTROL AS
420D, 428D, 432D, 442D
420D, 428D, 432D, 442D
2373655
CONTROL GP-POWER TRAIN
420D, 428D, 430D, 432D, 442D
420D, 428D, 430D, 432D, 442D