2628736 CONTROL GP-HANDLE Caterpillar parts
906H, 907H, 908H
Rating:
Alternative (cross code) number:
CA2628736
262-8736
2628736
CA2628736
262-8736
2628736
Weight: 0.58 pounds 0 kg.
COMPACT WHEEL LOADER,
This part in 4 request:
Show.
This information for suppliers only!
2023-04-05
2023-03-14
2020-03-23
2018-10-09
Information:
HVAC System
Illustration 1 g06215795
(1) Compressor
(2) Condenser
(3) Expansion orifice
(4) Evaporator
(5) Accumulator
(6) Water Valve
(7) Heater Coil
(8) Engine
(9) Brake ECM
(10) HVAC operator controls
(11) A/C Switch
(12) Condenser fan relays
(13) Condenser fan motors
(14) Blower resistor pack
(15) High-pressure switch
(16) A/C clutch relay
(17) Blower fan motor
(18) Recirculation temperature sensor
(19) Louver temperature sensor
(20) Low-pressure switch
(21) Thermostat switch
(22) Water valve actuator
(A) High temperature, high-pressure vapor
(B) High temperature, high-pressure liquid
(C) Low temperature, low-pressure liquid vapor mixture
(D) Low temperature, low-pressure vapor
(E) Coolant from engine
(F) High temperature coolant
(G) Medium temperature coolant
(H) Coolant to radiator
(J) Air from cab recirculation
(K) Air to cab louversThe HVAC system has three modes of operation: MANUAL, AUTO, and AIR CONDITIONING. The operator selects the mode of operation through the A/C Switch (11). In MANUAL mode the operator has direct control of the blower fan and heating system, but the air conditioning system is not engaged. In AUTO mode the operator sets a preferred temperature and the Machine ECM operates the heating and air conditioning system automatically. The operator still has direct control over the blower fan. In AIR CONDITIONING mode the air conditioning system is engaged but the operator still has direct control over the blower fan and heating system.Note: The HVAC system will not operate if the blower fan control is in the OFF.A/C System
The air conditioning system is activated either through operator request from the A/C switch (11) in air conditioning mode or from the machine ECM (9) when in auto mode and the ECM determines that the air conditioning should be activated.When the air conditioning system is activated, the machine ECM (9) sends a signal to A/C clutch relay (16). When the relay activates, power is provided to the A/C clutch on compressor (1). High-pressure switch (15) and low-pressure switch (20) verify that the high and low-pressure sides of the A/C system are functioning correctly. If either of the two switches detect pressures out of specifications, the machine ECM (9) receives a signal and shuts off the signal to the A/C clutch relay (16). Thermostat switch (21) monitors the temperature of the evaporator (4). When the temperature of evaporator coil drops below a specific point, machine ECM (9) receives a signal and shuts off the signal to the A/C clutch relay (16). Once the temperature of the evaporator coil raises back above the specific point, machine ECM (9) receives a signal and re-engages the signal to the A/C clutch relay (16). The process of the air conditioning system turning on and off is called cycling.When machine ECM (9) has engaged the air conditioning system, the air conditioner refrigerant begins to flow in the air conditioning system at the refrigerant compressor (1). The compressor is driven by a belt from the engine (8). The compressor is designed to change the air conditioner refrigerant from a vapor that has low pressure into a vapor that has high pressure. Also, the compressor changes the refrigerant from a vapor with low temperature to a vapor with high temperature. The increase in pressure causes the increase in temperature.The refrigerant
Illustration 1 g06215795
(1) Compressor
(2) Condenser
(3) Expansion orifice
(4) Evaporator
(5) Accumulator
(6) Water Valve
(7) Heater Coil
(8) Engine
(9) Brake ECM
(10) HVAC operator controls
(11) A/C Switch
(12) Condenser fan relays
(13) Condenser fan motors
(14) Blower resistor pack
(15) High-pressure switch
(16) A/C clutch relay
(17) Blower fan motor
(18) Recirculation temperature sensor
(19) Louver temperature sensor
(20) Low-pressure switch
(21) Thermostat switch
(22) Water valve actuator
(A) High temperature, high-pressure vapor
(B) High temperature, high-pressure liquid
(C) Low temperature, low-pressure liquid vapor mixture
(D) Low temperature, low-pressure vapor
(E) Coolant from engine
(F) High temperature coolant
(G) Medium temperature coolant
(H) Coolant to radiator
(J) Air from cab recirculation
(K) Air to cab louversThe HVAC system has three modes of operation: MANUAL, AUTO, and AIR CONDITIONING. The operator selects the mode of operation through the A/C Switch (11). In MANUAL mode the operator has direct control of the blower fan and heating system, but the air conditioning system is not engaged. In AUTO mode the operator sets a preferred temperature and the Machine ECM operates the heating and air conditioning system automatically. The operator still has direct control over the blower fan. In AIR CONDITIONING mode the air conditioning system is engaged but the operator still has direct control over the blower fan and heating system.Note: The HVAC system will not operate if the blower fan control is in the OFF.A/C System
The air conditioning system is activated either through operator request from the A/C switch (11) in air conditioning mode or from the machine ECM (9) when in auto mode and the ECM determines that the air conditioning should be activated.When the air conditioning system is activated, the machine ECM (9) sends a signal to A/C clutch relay (16). When the relay activates, power is provided to the A/C clutch on compressor (1). High-pressure switch (15) and low-pressure switch (20) verify that the high and low-pressure sides of the A/C system are functioning correctly. If either of the two switches detect pressures out of specifications, the machine ECM (9) receives a signal and shuts off the signal to the A/C clutch relay (16). Thermostat switch (21) monitors the temperature of the evaporator (4). When the temperature of evaporator coil drops below a specific point, machine ECM (9) receives a signal and shuts off the signal to the A/C clutch relay (16). Once the temperature of the evaporator coil raises back above the specific point, machine ECM (9) receives a signal and re-engages the signal to the A/C clutch relay (16). The process of the air conditioning system turning on and off is called cycling.When machine ECM (9) has engaged the air conditioning system, the air conditioner refrigerant begins to flow in the air conditioning system at the refrigerant compressor (1). The compressor is driven by a belt from the engine (8). The compressor is designed to change the air conditioner refrigerant from a vapor that has low pressure into a vapor that has high pressure. Also, the compressor changes the refrigerant from a vapor with low temperature to a vapor with high temperature. The increase in pressure causes the increase in temperature.The refrigerant
Caterpillar parts catalog:
Parts control Caterpillar catalog:
2739189
CONTROL GP-TRANSMISSION
901C, 902C, 903C, 906H, 907H, 910K, 914K
901C, 902C, 903C, 906H, 907H, 910K, 914K
2955536
CONTROL & MTG GP-PEDAL
906H, 907H
906H, 907H
2628868
CONTROL GP-JOYSTICK
906H, 907H
906H, 907H
2425604
CONTROL GP-WORK TOOL
908H, 908H2
908H, 908H2
3164798
CONTROL GP-GOVERNOR
906H, 907H, 908H
906H, 907H, 908H
3513209
CONTROL GP-GOVERNOR
906H, 907H, 908H
906H, 907H, 908H
2763917
CONTROL AS-TEMPERATURE
906H, 906H2, 907H, 907H2, 908H, 908H2, 910K, 914K
906H, 906H2, 907H, 907H2, 908H, 908H2, 910K, 914K
2628759
CONTROL GP-HANDLE
906H, 907H, 908H
906H, 907H, 908H
3492344
CONTROL GP-HANDLE
906H, 906H2, 907H, 907H2, 908H, 908H2
906H, 906H2, 907H, 907H2, 908H, 908H2
3492345
CONTROL GP-HANDLE
906H, 906H2, 907H, 907H2, 908H, 908H2
906H, 906H2, 907H, 907H2, 908H, 908H2
2763917
CONTROL AS-TEMPERATURE
906H, 906H2, 907H, 907H2, 908H, 908H2, 910K, 914K
906H, 906H2, 907H, 907H2, 908H, 908H2, 910K, 914K
3083868
CONTROL AS-ELECTRONIC
120M, 12M, 140M, 14M, 160M, 16M, 770G, 770G OEM, 772G, 772G OEM, 773F, 775F, 777F, 938H, 950H, 962H, 966H, 972H, 980H, 988H, IT38H, IT62H
120M, 12M, 140M, 14M, 160M, 16M, 770G, 770G OEM, 772G, 772G OEM, 773F, 775F, 777F, 938H, 950H, 962H, 966H, 972H, 980H, 988H, IT38H, IT62H
2773282
CONTROL GP-HANDLE
950H, 962H, 966H, 972H, IT62H
950H, 962H, 966H, 972H, IT62H
2773279
CONTROL GP-HANDLE
950H, 962H, 966H, 972H, IT62H
950H, 962H, 966H, 972H, IT62H
3789174
CONTROL AS-MONITORING
924K, 930K, 938K
924K, 930K, 938K
3492345
CONTROL GP-HANDLE
906H, 906H2, 907H, 907H2, 908H, 908H2
906H, 906H2, 907H, 907H2, 908H, 908H2
3492344
CONTROL GP-HANDLE
906H, 906H2, 907H, 907H2, 908H, 908H2
906H, 906H2, 907H, 907H2, 908H, 908H2
2628759
CONTROL GP-HANDLE
906H, 907H, 908H
906H, 907H, 908H