Information:
Test Procedure
System Operation
The SLC 5/04 - 5/05 indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: input devices, output devices, wiring and the controller.When the red LED is illuminated, there is a fatal error. A fatal error indicates that the processor is not communicating.
Illustration 1 g00766225
Diagram of the LED indicators
Illustration 2 g00562937
Central Processing Unit for typical systemFunctional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 542/552.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 4.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Test the memory module.
To avoid damage to electronic components, do not remove the processor from the SLC 5/04 Chassis until all power is removed from the power supply.Do not expose memory modules to surfaces or areas that may typically hold an electrostatic charge.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Remove the processor from the chassis.
Remove the memory module.
Install the processor.
Connect the power supply.
Energize the PLC.ReferenceMaintenance Procedure, "Memory Module - Replace"The results of the preceding procedure are in the following list:
The "FLT" LED is flashing. Replace the memory module. Refer to Maintenance Procedure, "Memory Module - Replace". Stop.
The "FLT" LED is steady. Install the memory module. Proceed to 4.
Check the line voltage.
Reconnect the power supply.
Measure the line voltage at the terminals.
Verify the voltage of the power supply. The power supply voltage should be measured between 21.0 VDC and 28.0 VDC.The results of the preceding procedure are in the following list:
The line voltage is in the range. Install the processor in another chassis. Verify the diagnostic indicators. The fault is present. Replace the processor. Verify that the repair solves the problem. Refer to Maintenance Procedure, "Processor - Replace".
The line voltage is out of the range. Refer to Troubleshooting, "System Power". Stop.
System Operation
The SLC 5/04 - 5/05 indicators are located on the front of the following components: Power Supply, CPU and I/O Modules.The diagnostic indicators help trace the source of the fault. Faults can be found in the following components: input devices, output devices, wiring and the controller.When the red LED is illuminated, there is a fatal error. A fatal error indicates that the processor is not communicating.
Illustration 1 g00766225
Diagram of the LED indicators
Illustration 2 g00562937
Central Processing Unit for typical systemFunctional Test
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 542/552.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 4.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Cycle the power.
Secure power to the PLC.
Energize the PLC.The results of the preceding procedure are in the following list:
No errors are displayed on the LED indicators. Stop.
Errors are displayed on the LED indicators. Proceed to 3.
Test the memory module.
To avoid damage to electronic components, do not remove the processor from the SLC 5/04 Chassis until all power is removed from the power supply.Do not expose memory modules to surfaces or areas that may typically hold an electrostatic charge.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Remove the processor from the chassis.
Remove the memory module.
Install the processor.
Connect the power supply.
Energize the PLC.ReferenceMaintenance Procedure, "Memory Module - Replace"The results of the preceding procedure are in the following list:
The "FLT" LED is flashing. Replace the memory module. Refer to Maintenance Procedure, "Memory Module - Replace". Stop.
The "FLT" LED is steady. Install the memory module. Proceed to 4.
Check the line voltage.
Reconnect the power supply.
Measure the line voltage at the terminals.
Verify the voltage of the power supply. The power supply voltage should be measured between 21.0 VDC and 28.0 VDC.The results of the preceding procedure are in the following list:
The line voltage is in the range. Install the processor in another chassis. Verify the diagnostic indicators. The fault is present. Replace the processor. Verify that the repair solves the problem. Refer to Maintenance Procedure, "Processor - Replace".
The line voltage is out of the range. Refer to Troubleshooting, "System Power". Stop.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts control Caterpillar catalog:
3E7843
CONTROL GP-BUCKET POSITIONER
416C, 420D, 420E, 426C, 428C, 428D, 428E, 430D, 430E, 432D, 432E, 434E, 436C, 438C, 438D, 442D, 442E, 444E, 902, 906, 908, 910E, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 93...
416C, 420D, 420E, 426C, 428C, 428D, 428E, 430D, 430E, 432D, 432E, 434E, 436C, 438C, 438D, 442D, 442E, 444E, 902, 906, 908, 910E, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 93...
1449923
CONTROL GP-STEERING
902, 906, 908
902, 906, 908
1417556
CONTROL GP-ELECTRONIC FILTER
902, 906, 908, AP-655C, CB-434D, CB-534D, CB-634D, D8R
902, 906, 908, AP-655C, CB-434D, CB-534D, CB-634D, D8R
1377744
CONTROL GP-SERVICE BRAKE
902, 906
902, 906
2122204
CONTROL GP-AIR CONDITIONER
246C, 256C, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 906, 908, CB-44B, CB-54B, CD-54B, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
246C, 256C, 262C, 262C2, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 906, 908, CB-44B, CB-54B, CD-54B, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
1380230
CONTROL GP-PARKING BRAKE
902, 906, 908
902, 906, 908
1380241
CONTROL GP-STEERING
902, 906, 908
902, 906, 908
1954940
CONTROL GP-CREEPER
902, 906
902, 906
2086093
CONTROL GP-HANDLE
902, 906, 908
902, 906, 908
2086096
CONTROL GP-HANDLE
902, 906, 908
902, 906, 908
2230715
CONTROL GP-HANDLE
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 511, 521, 522, 532, 541, 551, 552, TK711, TK721, TK722, TK732, TK741, TK751, TK752
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 511, 521, 522, 532, 541, 551, 552, TK711, TK721, TK722, TK732, TK741, TK751, TK752
3642742
CONTROL GP-GOVERNOR
C1.1, C1.5
C1.1, C1.5
2247383
CONTROL GP-COLD PLANER
PC206, PC310B
PC206, PC310B
2204768
CONTROL GP-COLD PLANER
PC206, PC310B
PC206, PC310B
2195415
CONTROL GP-COLD PLANER
PC206, PC310B
PC206, PC310B
2870526
CONTROL GP-HANDLE
906, 908
906, 908