Information:
Removal Procedure
Personal injury can result from contact with refrigerant.This system is under pressure at all times, even if the engine is not running. Heat should never be applied to a charged system.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, evacuate the system recovering the refrigerant before removing the fitting.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel away from the machine or where they can be seen.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g01157022
Disconnect harness assembly (2). Disconnect hose assemblies (1). Remove bolts (4) and clamps (5). Remove refrigerant receiver-dryer (3) .Installation Procedure
Illustration 2 g01157022
Install refrigerant receiver-dryer (3). Install bolts (4) and clamps (5). Connect hose assemblies (1). Connect harness assembly (2).
Charge the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Personal injury can result from contact with refrigerant.This system is under pressure at all times, even if the engine is not running. Heat should never be applied to a charged system.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use caution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, evacuate the system recovering the refrigerant before removing the fitting.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Before any checks of the air conditioning and heating system are made, move the machine to a smooth horizontal surface. Lower all implements to the ground. Make sure the transmission is in neutral or park and that the parking brake is engaged. Keep all other personnel away from the machine or where they can be seen.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g01157022
Disconnect harness assembly (2). Disconnect hose assemblies (1). Remove bolts (4) and clamps (5). Remove refrigerant receiver-dryer (3) .Installation Procedure
Illustration 2 g01157022
Install refrigerant receiver-dryer (3). Install bolts (4) and clamps (5). Connect hose assemblies (1). Connect harness assembly (2).
Charge the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts control Caterpillar catalog:
2395025
CONTROL GP-UNPRGMED MONITOR
140G, 3126B, 3412E, 3606, 3608, 3612, 3616, 621B, 627F, 631D, 637D, 657E, 725, 730, 735, 740, 770, 772, 815B, 824C, 844K, 854K, 938H, 950H, 953D, 962H, 963D, 966H, 972H, 973D, 980C, 980G, 980H, 990K, ...
140G, 3126B, 3412E, 3606, 3608, 3612, 3616, 621B, 627F, 631D, 637D, 657E, 725, 730, 735, 740, 770, 772, 815B, 824C, 844K, 854K, 938H, 950H, 953D, 962H, 963D, 966H, 972H, 973D, 980C, 980G, 980H, 990K, ...
2945559
CONTROL GP-TRANSMISSION HYD
770, 772
770, 772
3838125
CONTROL GP-COMMUNICATION
770, 772
770, 772
2785962
CONTROL GP-GOVERNOR
770, 772
770, 772
2851133
CONTROL GP-UNPROGRAMMED
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 140K, 140K 2, 140M, 140M 2, 14M, 160K, 160M, 160M 2, 16M, 2384C, 2470C, 2484C, 24M, 2570C, 2670C, 2864C, 311D LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2...
120K, 120K 2, 120M, 120M 2, 12K, 12M, 12M 2, 140K, 140K 2, 140M, 140M 2, 14M, 160K, 160M, 160M 2, 16M, 2384C, 2470C, 2484C, 24M, 2570C, 2670C, 2864C, 311D LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2...
3722905
CONTROL GP-ELECTRONIC
120K, 12K, 12M, 140G, 140K, 140M, 140M 2, 14M, 160K, 160M, 160M 2, 16M, 2290, 2390, 2391, 2491, 24M, 2590, 345D L, 511, 521, 521B, 522, 522B, 525C, 532, 535C, 541, 541 2, 545C, 551, 552, 552 2, 583T, ...
120K, 12K, 12M, 140G, 140K, 140M, 140M 2, 14M, 160K, 160M, 160M 2, 16M, 2290, 2390, 2391, 2491, 24M, 2590, 345D L, 511, 521, 521B, 522, 522B, 525C, 532, 535C, 541, 541 2, 545C, 551, 552, 552 2, 583T, ...
3043593
CONTROL GP-ELECTROHYDRAULIC
770, 772, 773F, 775F, 777F, 793F, 797F
770, 772, 773F, 775F, 777F, 793F, 797F
3043601
CONTROL GP-ELECTROHYDRAULIC
770, 772, 773F, 775F, 777F, 793F, 797F
770, 772, 773F, 775F, 777F, 793F, 797F
3216550
CONTROL AR-TRACTION
770, 772
770, 772
2777540
CONTROL AR-TRACTION
770, 772
770, 772
2360982
CONTROL GP-MACHINE
770, 772
770, 772
2318857
CONTROL GP-GOVERNOR
TH210, TH215
TH210, TH215
4209100
CONTROL GP-ELECTRONIC GOVERNOR
3512, 3516
3512, 3516
4209098
CONTROL GP-ELECTRONIC GOVERNOR
3512, 3516
3512, 3516
3107260
CONTROL GP-FOOT BRAKE
770, 772
770, 772
2795647
CONTROL GP-FOOT BRAKE
770, 772
770, 772
2187311
CONTROL GP-FOOT BRAKE
770, 772
770, 772
2360981
CONTROL GP-SERVICE BRAKE
770, 772
770, 772