Information:


Illustration 1 g02149193
Connections of the blade angle right solenoid
This diagnostic code is associated with the blade angle right solenoid. The FMI 05 means that the ECM has determined that an open in the circuit exists.The possible causes of this diagnostic code are listed:
The energize circuit of the solenoid is open.
The return circuit of the solenoid is open.
The solenoid has failed.
The ECM has failed. An ECM failure is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1934 - FMI 05 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. Check the solenoid
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the solenoid from the machine harness.
At the machine harness connector for the solenoid, place a jumper wire from contact "1" wire (K788-GY(Grey)) to contact "2" wire (H802-GY(Grey)).
Observe the status of the diagnostic code. Expected Result:The diagnostic code remains active. Then, the diagnostic code changes from FMI 05 to FMI 06 after the jumper wire is installed.Results:
YES - The diagnostic code remains active. The jumper wire does not affect the diagnostic code. Proceed to Test Step 2.
NO - The diagnostic is no longer active. The solenoid has failed.Repair: The solenoid has failed. Replace the solenoid. Verify that the new solenoid corrects the problem.STOPTest Step 2. Check the harness for an open
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the ECM.
The jumper wire that was installed in the previous test remains in place.
At the machine harness connector, measure the resistance from signal contact J1-61 wire (K788-GY(Grey)) to contact J1-60 wire (H802-GY(Grey)). Expected Result:The resistance is less than 5 ohms.Results:
YES - The resistance is less than 5 ohms. The machine harness is correct. Proceed to Test Step 3.
NO - The resistance is greater than 5000 ohms. The resistance measurement is not correct. There is an open circuit in the machine harness.Repair: The open is in wire (K788-GY(Grey)) or in wire (H802-GY(Grey)) of the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. Check the operation of the ecmThe disconnect switch and the key start switch remain in the OFF position. The machine harness connector for the solenoid and the ECM connectors remain disconnected.
Remove the jumper wire that was installed in the last test step.
At the J1 connector for the ECM, use a wire removal tool to remove wire (K788-GY(Grey)) from contact J1-61.
Reconnect the machine harness connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Use a multimeter probe to make a connection with the ECM at contact J1-61 through the empty space in the J1 connector.
Observe the status of the diagnostic code. Ground the other end of the multimeter probe to frame ground. Expected Result:The FMI 05 changes

Caterpillar parts catalog:

Caterpillar parts catalog
C18 Emergency Diesel Generator Set DDS00001-UP POWERED BY C18 Engine


Parts control Caterpillar catalog:

1180175 CONTROL GP-EMCP ELECTRONIC
3126B, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C, C-12, C15, C18, C27, C32, C9, G3304, G3306, G3306B, G3406, G34...
1545505 CONTROL GP-ENGINE MONITORING
3406C, 3406E, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C18
3091583 CONTROL AS-GOVERNOR
3126B, 3406E, 3412, 3412C, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C-12, C15, C175-16, C175-20, C18, C27, C280-12, C280-16, C280-6, C32, C9, G3406, G3412, G3512E, G3520C, G35...
1610797 CONTROL AS-GOVERNOR
3412, 3412C, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C280-12, C280-16, C280-6, C280-8, C9, G3406, G3606, G3608, G3612, G3616, PM3412, PP3516
1694701 CONTROL GP-EMCP ELECTRONIC
3126B, 3406C, 3406E, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C-12, C18, C32
1375525 CONTROL GP-EMCP ELECTRONIC
3208, 3304B, 3306B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C15, C18, G3304, G3306, G3306B, G3406, G3408, G3408B, G3408C, G3412, G3508, G3512, G3516, G3516...
1435464 CONTROL GP-EMCP ELECTRONIC
3406C, 3406E, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C18, C32
1435465 CONTROL GP-EMCP ELECTRONIC
3406C, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, C18
2341644 CONTROL GP-ENGINE MONITORING
3406C, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C175-16, C18, C27, C32, C9, PP3516
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.