3633702 CONTROL AR-HYDRAULIC IMPLEMENT Caterpillar parts
D9R
Rating:
Alternative (cross code) number:
CA3633702
363-3702
3633702
CA3633702
363-3702
3633702
TRACK-TYPE TRACTOR,
Compatible equipment models: 3633702:
3633702
Images:
Information:
Introduction
By default, the Light Bar Scales option is available for all configurations of AccuGrade System. Depending on the operator configuration settings for your system, some of the options, soft keys, or views discussed in this manual may not be accessible.Operate to an on-grade tolerance threshold appropriate for the design surface. The Light Bar Scales dialogs set the vertical and horizontal tolerances that apply to the LEDs on the light bars. The horizontal and vertical light bars are set independently of each other.Tolerance Thresholds
A tolerance threshold for vertical light bars is the distance off-grade at which two LEDs will be lit. A tolerance threshold for horizontal light bars is the distance off-line at which two LEDs will be lit.When the blade is on-grade (on-line) to within half the tolerance threshold, only the center green LED on the appropriate light bar is lit. As the blade moves offgrade (off-line), additional LEDs are lit.Other LED distances are automatically scaled from the tolerance threshold.The vertical tolerance threshold also determines the on-grade tolerance. The on-grade tolerance is the vertical range where the blade is considered to be on-grade. When the blade is in the on-grade range, the Cut/Fill text items and the associated direction arrow are green.When the blade is out of the on-grade range, one of the following things will occur:
The Cut text item and the down arrow will be red.
The Fill text item and the up arrow will be blue.Setting the Light Bar Scales
In order to set the tolerance thresholds, complete the following steps:
From the Setup Menu – Configuration dialog, press the Down arrow or the Up arrow until "Light Bar Scales" is highlighted.
Illustration 1 g01269826
Press the OK key. Refer to Illustration 1.
In the Light Bar Scales dialogs, press "Vertical" in order to set the vertical light bar scale. Use any of the following tools to edit the vertical tolerance value:
If you work in meters, press "Default Set 0.050" to set your tolerance to the default value of 0.050 m. If you work in US FT or feet, press "Default Set 0.200".
Use
By default, the Light Bar Scales option is available for all configurations of AccuGrade System. Depending on the operator configuration settings for your system, some of the options, soft keys, or views discussed in this manual may not be accessible.Operate to an on-grade tolerance threshold appropriate for the design surface. The Light Bar Scales dialogs set the vertical and horizontal tolerances that apply to the LEDs on the light bars. The horizontal and vertical light bars are set independently of each other.Tolerance Thresholds
A tolerance threshold for vertical light bars is the distance off-grade at which two LEDs will be lit. A tolerance threshold for horizontal light bars is the distance off-line at which two LEDs will be lit.When the blade is on-grade (on-line) to within half the tolerance threshold, only the center green LED on the appropriate light bar is lit. As the blade moves offgrade (off-line), additional LEDs are lit.Other LED distances are automatically scaled from the tolerance threshold.The vertical tolerance threshold also determines the on-grade tolerance. The on-grade tolerance is the vertical range where the blade is considered to be on-grade. When the blade is in the on-grade range, the Cut/Fill text items and the associated direction arrow are green.When the blade is out of the on-grade range, one of the following things will occur:
The Cut text item and the down arrow will be red.
The Fill text item and the up arrow will be blue.Setting the Light Bar Scales
In order to set the tolerance thresholds, complete the following steps:
From the Setup Menu – Configuration dialog, press the Down arrow or the Up arrow until "Light Bar Scales" is highlighted.
Illustration 1 g01269826
Press the OK key. Refer to Illustration 1.
In the Light Bar Scales dialogs, press "Vertical" in order to set the vertical light bar scale. Use any of the following tools to edit the vertical tolerance value:
If you work in meters, press "Default Set 0.050" to set your tolerance to the default value of 0.050 m. If you work in US FT or feet, press "Default Set 0.200".
Use
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts control Caterpillar catalog:
1567172
CONTROL GP-ENGINE ELECTRONIC
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD45, AE40 II,...
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD45, AE40 II,...
1930327
CONTROL & MTG GP-ENGINE ELEK
D8L, D9N, D9R
D8L, D9N, D9R
9N1822
CONTROL GP-GOVERNOR
3406, 3406B, 3406C, 3408, 589, D10N, D11N, D350E, D400E, D40D, D8L, D9L, D9N, D9R, HT400
3406, 3406B, 3406C, 3408, 589, D10N, D11N, D350E, D400E, D40D, D8L, D9L, D9N, D9R, HT400
1253420
CONTROL GP-DECELERATOR
D10N, D10R, D11R, D8L, D9L, D9N, D9R
D10N, D10R, D11R, D8L, D9L, D9N, D9R
1656059
CONTROL GP-FAN
D10R, D9R
D10R, D9R
9X1138
CONTROL AS-ELECTRONIC
D10N, D10R, D11N, D11R, D9N, D9R
D10N, D10R, D11N, D11R, D9N, D9R
1329896
CONTROL GP-MONITOR
D10N, D11N, D9N, D9R
D10N, D11N, D9N, D9R
1796273
CONTROL AR-TRANSMISSION
428C, 438C
428C, 438C
3353870
CONTROL AR-WORK TOOL
320D FM RR
320D FM RR
1836505
CONTROL GP-PEDAL
953C, 963C, 973C
953C, 963C, 973C
1074702
CONTROL GP-SERVICE BRAKE
914G, IT14G
914G, IT14G
1636501
CONTROL GP-SERVICE BRAKE
854G, 992G
854G, 992G
3605661
CONTROL GP-COMMUNICATION
770G, 770G OEM, 772G, 772G OEM
770G, 770G OEM, 772G, 772G OEM
2889868
CONTROL GP-JOYSTICK
D6K LGP
D6K LGP
1237849
CONTROL GP-PILOT OPERATED HYD
TH62, TH63, TH82, TH83
TH62, TH63, TH82, TH83