3724305 CONTROL GP-GENERATOR SET Caterpillar parts
3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C175-20, G3516H
Rating:
Alternative (cross code) number:
CA3724305
372-4305
3724305
CA3724305
372-4305
3724305
GENERATOR SET,
Compatible equipment models: 3724305:
Information:
Adjustable Thermostat
A Heating Ventilation Air Conditioning (HVAC) system that is controlled by an adjustable thermostat contains two temperature control knobs.The first temperature control knob is for the air conditioning system and the control knob is connected to the adjustable thermostat.A thermostat is a switch that opens and closes. The thermostat switch opens and the thermostat switch closes because of the changes that can occur in the temperature of the sensing element. A sensing element is also known as a capillary tube. Sensing temperatures for the element less than the switch point on the thermostat will open the thermostat switch. Sensing temperatures for the element more than the switch point for the thermostat will close the thermostat switch.When the first temperature control knob is in the OFF position, the electric circuit that connects the adjustable thermostat and the magnetic clutch is OPEN. In the OFF position, the compressor does not operate. The temperature of the air and the position of the temperature control knob determines if the thermostat switch is CLOSED. When the thermostat switch is CLOSED, the current moves through the switch and the coil assembly in the magnetic clutch, and this causes the compressor to operate. The temperature of the air through the evaporator coil is monitored by the capillary tube that is placed between the fins of the evaporator coil.The second temperature control knob is for heating. This knob is connected to the heater control valve, which controls the flow of coolant through the heater coil. The temperature of the cab is maintained by the position of the air conditioning and heating temperature control knobs.Nonadjustable Thermostat (Freeze Control System)
Illustration 1 g01510274An HVAC system using a nonadjustable thermostat contains one temperature control knob. The temperature control knob is connected to the heater control valve, which controls the flow of coolant through the heater coil. The temperature of the cab is maintained by the position of the temperature control knob on the heater.The temperature of the air that crosses the evaporator coil is kept at the coldest possible temperature allowed by the nonadjustable thermostat. The thermostat switch opens at a temperature of approximately −1.1 °C (30 °F) in order to prevent the condensation from freezing to the evaporator coil. In addition, the thermostat switch closes at approximately 2.2 °C (36 °F). Condensation that is frozen will restrict the air flow through the evaporator coils. When the switch opens, the electric circuit that connects the thermostat switch to the magnetic clutch is OPEN and the compressor does not operate. When the switch is CLOSED, the current moves through the switch and through the coil assembly in the magnetic clutch. This causes the compressor to operate. In order to operate the system in the correct manner, the heater core supply must not be closed. Also, in order to operate the system in the correct manner, the return coolant line valve must not be closed.ATC System Operation
Illustration 2 g03090876
Typical HVAC Components
The Automatic Temperature Control (ATC) system includes all of the standard HVAC
A Heating Ventilation Air Conditioning (HVAC) system that is controlled by an adjustable thermostat contains two temperature control knobs.The first temperature control knob is for the air conditioning system and the control knob is connected to the adjustable thermostat.A thermostat is a switch that opens and closes. The thermostat switch opens and the thermostat switch closes because of the changes that can occur in the temperature of the sensing element. A sensing element is also known as a capillary tube. Sensing temperatures for the element less than the switch point on the thermostat will open the thermostat switch. Sensing temperatures for the element more than the switch point for the thermostat will close the thermostat switch.When the first temperature control knob is in the OFF position, the electric circuit that connects the adjustable thermostat and the magnetic clutch is OPEN. In the OFF position, the compressor does not operate. The temperature of the air and the position of the temperature control knob determines if the thermostat switch is CLOSED. When the thermostat switch is CLOSED, the current moves through the switch and the coil assembly in the magnetic clutch, and this causes the compressor to operate. The temperature of the air through the evaporator coil is monitored by the capillary tube that is placed between the fins of the evaporator coil.The second temperature control knob is for heating. This knob is connected to the heater control valve, which controls the flow of coolant through the heater coil. The temperature of the cab is maintained by the position of the air conditioning and heating temperature control knobs.Nonadjustable Thermostat (Freeze Control System)
Illustration 1 g01510274An HVAC system using a nonadjustable thermostat contains one temperature control knob. The temperature control knob is connected to the heater control valve, which controls the flow of coolant through the heater coil. The temperature of the cab is maintained by the position of the temperature control knob on the heater.The temperature of the air that crosses the evaporator coil is kept at the coldest possible temperature allowed by the nonadjustable thermostat. The thermostat switch opens at a temperature of approximately −1.1 °C (30 °F) in order to prevent the condensation from freezing to the evaporator coil. In addition, the thermostat switch closes at approximately 2.2 °C (36 °F). Condensation that is frozen will restrict the air flow through the evaporator coils. When the switch opens, the electric circuit that connects the thermostat switch to the magnetic clutch is OPEN and the compressor does not operate. When the switch is CLOSED, the current moves through the switch and through the coil assembly in the magnetic clutch. This causes the compressor to operate. In order to operate the system in the correct manner, the heater core supply must not be closed. Also, in order to operate the system in the correct manner, the return coolant line valve must not be closed.ATC System Operation
Illustration 2 g03090876
Typical HVAC Components
The Automatic Temperature Control (ATC) system includes all of the standard HVAC
Caterpillar SIS machinery equipment:
Caterpillar SIS
G3512 Generator Set E2P00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3512 Generator Set E2T00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516E Generator Set JH800001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516H Generator Set NWJ00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516H Generator Set NWH00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set NWD00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set NWE00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set NWF00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516E Generator Set NWG00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512C Generator Set RRM00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3512H Generator Set GF400001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set F6M00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3512H Generator Set GF500001-UP »
372-4305
CONTROL GP-GENERATOR SET
C27 Generator Set 2A300001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512C Generator Set LYP00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set NG600001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516 Generator Set LY200001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set LY300001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set LY400001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set LY500001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set LY600001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set LYM00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set N6R00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516E Generator Set GWZ00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512B Generator Set LY800001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512 Generator Set LY700001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512C Generator Set LYH00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512B Generator Set LY900001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set FF200001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set F4H00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516B Generator Set E6T00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set PXY00001-UP »
372-4305
CONTROL GP-GENERATOR SET
C32 Generator Set PAE00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520 Generator Set E2J00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520 Generator Set E2K00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520 Generator Set E2800001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520 Generator Set E2900001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3512 Natural Gas Generator Set E2600001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3512 Natural Gas Generator Set E2700001-UP »
372-4305
CONTROL GP-GENERATOR SET
C32 Generator Set P7E00001-UP »
372-4305
CONTROL GP-GENERATOR SET
C175–16 Generator Set TB800001-UP »
372-4305
CONTROL GP-GENERATOR SET
C175–16 Generator Set TE800001-UP »
372-4305
CONTROL GP-GENERATOR SET
C175–20 Generator Set TZ800001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set HPY00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set HCY00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set PBR00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516 Generator Set ZAZ00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516 Generator Set ZBA00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516B Generator Set ZBC00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520C Generator Set GZL00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520C Generator Set GZJ00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512B Generator Set ZAH00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512B Generator Set ZAJ00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516 Generator Set ZAL00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set ZAP00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set ZAR00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set SBJ00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512C Generator Set SBG00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set SBK00001-UP »
372-4305
CONTROL GP-GENERATOR SET
C175-16 Generator Set WYB00001-UP »
372-4305
CONTROL GP-GENERATOR SET
C175–20 Generator Set BXR00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520C Generator Set LGS00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520C Generator Set RLP00001-UP »
372-4305
CONTROL GP-GENERATOR SET
C32 Generator SET JSJ00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512B Generator Set YAM00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512B Generator Set YAN00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set YAT00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set YAW00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520C Generator Set GZA00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520C Generator Set GZB00001-UP »
372-4305
CONTROL GP-GENERATOR SET
C175–16 Generator Set WYC00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set SCJ00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set SCK00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3520E Gas Generator Set GZE00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516H Generator Set GLM00001-UP »
372-4305
CONTROL GP-GENERATOR SET
C27 Generator Set GDS00001-UP »
372-4305
CONTROL GP-GENERATOR SET
C32 Generator Set JAZ00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512 Generator Set YBA00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512B Generator Set YBB00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512B Generator Set YBC00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3512C Generator Set YBD00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516 Generator Set JCW00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516 Generator Set E6R00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516 Gas Generator Set E6W00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516 Generator Set ZBL00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set ZBP00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set PDR00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516B Generator Set ZBR00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set SEK00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set SFJ00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set SKC00001-UP »
372-4305
CONTROL GP-GENERATOR SET
3516C Generator Set SFK00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516B Generator Set L6H00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516B Generator Set L6J00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set F6D00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set F6E00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516C Generator Set F6F00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516E Generator Set F6G00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516 Generator Set E6Z00001-UP »
372-4305
CONTROL GP-GENERATOR SET
G3516 Generator Set E6200001-UP »
372-4305
CONTROL GP-GENERATOR SET
Cat SIS web machinery list:
Parts control Caterpillar catalog:
1180175
CONTROL GP-EMCP ELECTRONIC
3126B, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C, C-12, C15, C18, C27, C32, C9, G3304, G3306, G3306B, G3406, G34...
3126B, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C, C-12, C15, C18, C27, C32, C9, G3304, G3306, G3306B, G3406, G34...
1610797
CONTROL AS-GOVERNOR
3412, 3412C, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C280-12, C280-16, C280-6, C280-8, C9, G3406, G3606, G3608, G3612, G3616, PM3412, PP3516
3412, 3412C, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C280-12, C280-16, C280-6, C280-8, C9, G3406, G3606, G3608, G3612, G3616, PM3412, PP3516
1315453
CONTROL AS-ELECTRONIC GOVERNOR
3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, 3516C, C15, C18, G3304, G3306, G3306B, G3406, G3408, G3408B, G3412, G3508, G...
3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, 3516C, C15, C18, G3304, G3306, G3306B, G3406, G3408, G3408B, G3412, G3508, G...
2567512
CONTROL GP-COMMUNICATION
3176B, 3176C, 3196, 3406E, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, C175-16, C18, C280-12, C280-16, CG137-12, G3406, G3408, G3408C, G3412, G3508, G3508B, G3512, G3512B, G3512E, G3516, G3516B, G...
3176B, 3176C, 3196, 3406E, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, C175-16, C18, C280-12, C280-16, CG137-12, G3406, G3408, G3408C, G3412, G3508, G3508B, G3512, G3512B, G3512E, G3516, G3516B, G...
1445572
CONTROL AS-SYNCHRONIZE
3412, 3508, 3508B, 3512, 3512B, 3516, 3516B, G3516, PM3508, PM3512, PM3516, PMG3516
3412, 3508, 3508B, 3512, 3512B, 3516, 3516B, G3516, PM3508, PM3512, PM3516, PMG3516
1384961
CONTROL
3508, 3508B, 3512, 3512B, 3516, 3516B, PM3508, PM3512, PM3516
3508, 3508B, 3512, 3512B, 3516, 3516B, PM3508, PM3512, PM3516
1282727
CONTROL-ENGINE ELECTRONIC
3508, 3508B, 3512, 3512B, 3516, 3516B, PM3508, PM3512, PM3516
3508, 3508B, 3512, 3512B, 3516, 3516B, PM3508, PM3512, PM3516
3539994
CONTROL GP-GENERATOR SET
3406C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C13 XQ350, C15, C15 I6, C175-16, C175-20, C18, C18 I6, C27, C32, C4.4, C6.6, C7.1, C9, G3406, G3412
3406C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C13 XQ350, C15, C15 I6, C175-16, C175-20, C18, C18 I6, C27, C32, C4.4, C6.6, C7.1, C9, G3406, G3412
2790864
CONTROL AS-MONITORING
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C27, C32
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C175-16, C27, C32
3722908
CONTROL GP-UNPROGRAMMED
3512C, 3516B, 793F, 793F-XQ, C175-16, C175-20, C27
3512C, 3516B, 793F, 793F-XQ, C175-16, C175-20, C27
3722910
CONTROL GP-UNPROGRAMMED
12M 2, 12M 3, 140M 2, 160M 2, 3516C, 390F L, 627H, 627K, 725C, 770G, 770G OEM, 772G, 772G OEM, 824K, 825K, 826K, 834K, 836K, 988K, C175-16, C9, D6T LGP, D6T XL, D7E, D7E LGP, D9T, TH31-E61
12M 2, 12M 3, 140M 2, 160M 2, 3516C, 390F L, 627H, 627K, 725C, 770G, 770G OEM, 772G, 772G OEM, 824K, 825K, 826K, 834K, 836K, 988K, C175-16, C9, D6T LGP, D6T XL, D7E, D7E LGP, D9T, TH31-E61
3225521
CONTROL GP-PEDAL
D7E, D7E LGP
D7E, D7E LGP
1898248
CONTROL GP-OVERRIDE
972G II
972G II
3556655
CONTROL & MTG GP-ELECTRONIC
CG137-12
CG137-12
3875780
CONTROL GP-BUCKET
950 GC
950 GC
1453056
CONTROL GP-PEDAL
365B, 365B II, 385B, 5090B