7X1362 CONTROL GP-ELECTRONIC Caterpillar parts
621E, 623E, 627E, 627F, 631E, 637E, 651E, 657E, 768C, 769C, 771C, 772B, 773B, 776C, 777B, 784B, 785, 785B, 789, 789B, 793B
Rating:
Alternative (cross code) number:
CA7X1362
7X-1362
7X1362
CA7X1362
7X-1362
7X1362
Weight: 1 pounds 0 kg.
QUARRY TRUCK, WHEEL TRACTOR,
Compatible equipment models: 7X1362:
Information:
D311, D320, D330, D333, D342, D343, D353, D379, D398 Engines Equipped With SRSE GeneratorsSUPPLEMENT: 08/26/81ENGINE NEWS APRIL 1, 1981, PAGES 4 AND 5.In the article, "Test Procedure For Exciter Reactors On SRSE Generators" that starts on Page 4, the voltages shown on the second line of the "Voltage Test Chart" on Page 5 are not correct. Change the voltages for the 5L7024 and 5L7039 Reactors to read: X2, 59.8-66.2; Y2, 95.0-105.0; Z2, 2.46-2.74.
--------------- END SUPPLEMENT ---------------SUPPLEMENT: 05/21/81ENGINE NEWS, APRIL 1, 1981, PAGES 4 AND 5.In the article, "Test Procedure For Exciter Reactors On SRSE Generators" that starts on Page 4, a correction is needed to the last paragraph of the article (Connection "Z2" is wrongly shown as "Z3"). Under "Exciter Reactor Winding Test", change Step 4 to read:
4. Check the X2, Y2, and Z2 voltages found in Step 2 with the respective X2, Y2, and Z2 voltages shown in the chart, or the corrected voltages if corrections were made in Step 3. Each of these voltages must be in the range shown for the specific winding and reactor.
--------------- END SUPPLEMENT ---------------A test procedure is now available to easily check the exciter reactor during troubleshooting of Statically Regulated-Statically Excited (SRSE) generators. The procedure that follows will permit checks of the exciter reactor polarity and the condition of the windings. To make the tests, AC (alternating current) and DC (direct current) voltmeters are needed. The 6V3030 Digital Multimeter Group can be used, or other voltmeters which have the necessary range, including panel types with a dial face and needle.
Exciter Reactor Polarity Test
1. Connect a 6 or 12 volt battery and switch to the H1 and H3 terminals, and a DC voltmeter to the X1 and X2 terminals as shown in Illustration 1. Be sure the positive (+) and negative (-) connections are correct, as shown.
Illustration 1. Connections for exciter reactor polarity test.2. Adjust the voltmeter to a 10 or 20 volt scale first. For some reactor windings, it will be necessary to use a lower voltage scale to get an indication.3. Look at the voltmeter and move the switch to the "ON" position. The desired indication is a positive (+) voltage on the digital multimeter, or a needle movement up the scale on a dial face voltmeter. The indication will be only temporary, and the meter will go back to zero.4. After two seconds or more, move the switch to the "OFF" position. The desired indication is a negative (-) voltage on the digital multimeter, or a needle movement down the scale (below the zero) on a dial face voltmeter. This indication, like the one in Step 3, will be only temporary, and the meter will go back to zero. Do not move the switch to either the "ON" or "OFF" position at intervals of less than two seconds minimum. Shorter intervals will not permit stability in the flow of current.5. Do Steps 3 and 4 again with the voltmeter connected to Y1 and Y2, then with the voltmeter connected
--------------- END SUPPLEMENT ---------------SUPPLEMENT: 05/21/81ENGINE NEWS, APRIL 1, 1981, PAGES 4 AND 5.In the article, "Test Procedure For Exciter Reactors On SRSE Generators" that starts on Page 4, a correction is needed to the last paragraph of the article (Connection "Z2" is wrongly shown as "Z3"). Under "Exciter Reactor Winding Test", change Step 4 to read:
4. Check the X2, Y2, and Z2 voltages found in Step 2 with the respective X2, Y2, and Z2 voltages shown in the chart, or the corrected voltages if corrections were made in Step 3. Each of these voltages must be in the range shown for the specific winding and reactor.
--------------- END SUPPLEMENT ---------------A test procedure is now available to easily check the exciter reactor during troubleshooting of Statically Regulated-Statically Excited (SRSE) generators. The procedure that follows will permit checks of the exciter reactor polarity and the condition of the windings. To make the tests, AC (alternating current) and DC (direct current) voltmeters are needed. The 6V3030 Digital Multimeter Group can be used, or other voltmeters which have the necessary range, including panel types with a dial face and needle.
Exciter Reactor Polarity Test
1. Connect a 6 or 12 volt battery and switch to the H1 and H3 terminals, and a DC voltmeter to the X1 and X2 terminals as shown in Illustration 1. Be sure the positive (+) and negative (-) connections are correct, as shown.
Illustration 1. Connections for exciter reactor polarity test.2. Adjust the voltmeter to a 10 or 20 volt scale first. For some reactor windings, it will be necessary to use a lower voltage scale to get an indication.3. Look at the voltmeter and move the switch to the "ON" position. The desired indication is a positive (+) voltage on the digital multimeter, or a needle movement up the scale on a dial face voltmeter. The indication will be only temporary, and the meter will go back to zero.4. After two seconds or more, move the switch to the "OFF" position. The desired indication is a negative (-) voltage on the digital multimeter, or a needle movement down the scale (below the zero) on a dial face voltmeter. This indication, like the one in Step 3, will be only temporary, and the meter will go back to zero. Do not move the switch to either the "ON" or "OFF" position at intervals of less than two seconds minimum. Shorter intervals will not permit stability in the flow of current.5. Do Steps 3 and 4 again with the voltmeter connected to Y1 and Y2, then with the voltmeter connected
Caterpillar parts catalog:
Parts control Caterpillar catalog:
9X5308
CONTROL GP-PAYLOAD ELECTRONIC
69D, 769D, 771D, 773D, 773E, 775D, 775E, 776C, 776D, 777B, 777D, 784B, 785, 785B, 789, 789B, 793, 793B
69D, 769D, 771D, 773D, 773E, 775D, 775E, 776C, 776D, 777B, 777D, 784B, 785, 785B, 789, 789B, 793, 793B
2395025
CONTROL GP-UNPRGMED MONITOR
140G, 3126B, 3412E, 3606, 3608, 3612, 3616, 621B, 627F, 631D, 637D, 657E, 725, 730, 735, 740, 770, 772, 815B, 824C, 844K, 854K, 938H, 950H, 953D, 962H, 963D, 966H, 972H, 973D, 980C, 980G, 980H, 990K, ...
140G, 3126B, 3412E, 3606, 3608, 3612, 3616, 621B, 627F, 631D, 637D, 657E, 725, 730, 735, 740, 770, 772, 815B, 824C, 844K, 854K, 938H, 950H, 953D, 962H, 963D, 966H, 972H, 973D, 980C, 980G, 980H, 990K, ...
1567172
CONTROL GP-ENGINE ELECTRONIC
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD45, AE40 II,...
24H, 3408E, 3412E, 5110B, 631D, 631E, 631G, 633E II, 637E, 637G, 651E, 657E, 69D, 769C, 769D, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 834B, 836, 844, 988B, 988F II, 990, 990 II, 992C, AD45, AE40 II,...
9X0377
CONTROL GP-ELECTRONIC
777B, 785, 789, 950F, 966F, D11N
777B, 785, 789, 950F, 966F, D11N
1719842
CONTROL GP-MONITOR
561M, 769C, 771C, 924F, D5M, D6M
561M, 769C, 771C, 924F, D5M, D6M
3E5370
CONTROL GP-ELECTRONIC
3116, 325, 325 L, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5080, 5130, 777B, 784B, 785, 785B, 789, 789B, 793, 793B, 814F, 815F, 816F, 844, 950F, 950F II, 960F, 966F, 966F II, 970F, 980F, 980F II...
3116, 325, 325 L, 325 LN, 330, 330 FM L, 330 L, 350, 375, 375 L, 5080, 5130, 777B, 784B, 785, 785B, 789, 789B, 793, 793B, 814F, 815F, 816F, 844, 950F, 950F II, 960F, 966F, 966F II, 970F, 980F, 980F II...
3E0461
CONTROL GP-ELECTRONIC
69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 784B, 785B, 789B, 793B, 793C, 936F, 963, 963B, 973, 992C, 994, 994D, AD40, AD45, AE40, AE40 II, R1300, R1600, R1700 II, R1700G, R2900
69D, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 775B, 775D, 775E, 784B, 785B, 789B, 793B, 793C, 936F, 963, 963B, 973, 992C, 994, 994D, AD40, AD45, AE40, AE40 II, R1300, R1600, R1700 II, R1700G, R2900
1856778
CONTROL GP-MONITOR
69D, 769D, 771D, 773D, 773E, 775D, 775E, 776C, 776D, 777D, 784B, 785B, 789B, 793B
69D, 769D, 771D, 773D, 773E, 775D, 775E, 776C, 776D, 777D, 784B, 785B, 789B, 793B
9W1062
CONTROL GP-ELECTRONIC
623E, 627E, 637E, 651E, 657E, 768C, 769C, 772B, 773B, 777B, 785, 789
623E, 627E, 637E, 651E, 657E, 768C, 769C, 772B, 773B, 777B, 785, 789
1069188
CONTROL GP-RELAY ELECTRONIC
120H, 12H, 135H, 140H, 160H, 621F, 627F, 631E, 633E II, 637E, 651E, 657E, D10R
120H, 12H, 135H, 140H, 160H, 621F, 627F, 631E, 633E II, 637E, 651E, 657E, D10R
1612355
CONTROL GP-UNPROGRAMMED
621G, 623G, 627G, 631G, 637G, 657E, 725, 730, 735, 740, AP-655C
621G, 623G, 627G, 631G, 637G, 657E, 725, 730, 735, 740, AP-655C
1569549
CONTROL GP-FAN REVERSING
345B II, 938G, 950G, 966G
345B II, 938G, 950G, 966G
1162026
CONTROL AS-ELECTRONIC
910E, 914G, 928G, 938G, 950G, 962G, 966G, 972G, IT12B, IT14G, IT28G, IT38G, IT62G
910E, 914G, 928G, 938G, 950G, 962G, 966G, 972G, IT12B, IT14G, IT28G, IT38G, IT62G
2627473
CONTROL GROUP
D6R III
D6R III
9W1409
CONTROL GP
621E, 623E, 627E, 631E, 637E, 651E, 657E, 769C, 772B, 773B, 777B, 785, 793
621E, 623E, 627E, 631E, 637E, 651E, 657E, 769C, 772B, 773B, 777B, 785, 793
9X7000
CONTROL GP-ELECTRONIC
621E, 623E, 627E, 631E, 637E, 651E, 657E, 769C, 772B, 773B, 777B, 785, 789, 793
621E, 623E, 627E, 631E, 637E, 651E, 657E, 769C, 772B, 773B, 777B, 785, 789, 793
7T6337
CONTROL GP-ELECTRONIC
621E, 623E, 627E, 631E, 637E, 651E, 657E, 769C, 773B, 777B, 785, 789
621E, 623E, 627E, 631E, 637E, 651E, 657E, 769C, 773B, 777B, 785, 789
9W0009
CONTROL GP-TMSN ELECTRONIC
621E, 627E, 637E, 651E, 657E
621E, 627E, 637E, 651E, 657E
6T6590
CONTROL GP
637E, 651E, 657E, 777, 785
637E, 651E, 657E, 777, 785
3T8230
CONTROL GP-ELECTRONIC
651E, 657E
651E, 657E