Illustration 1 g00728266
Schematic of solenoid 3
Illustration 2 g00729451
Location of solenoids (1) Solenoid 1 (2) Solenoid 2 (3) Solenoid 3 (4) Solenoid 4 (5) Solenoid 5 (6) Solenoid 6Use table 1 in order to determine the solenoids that are energized. Table 1 identifies the solenoids that are energized for each position on the shift lever.
Table 1
Information about the Solenoids    
Solenoid     Number of the Solenoid (1)     Number of the Contact    
Forward High     1     31    
Reverse     2     32    
Forward Low     3     33    
Speed Clutch 1     4     34    
Speed Clutch 2     5     35    
Speed Clutch 3     6     36    
Gear     Solenoid that is Energized    
Neutral     No solenoids are energized.    
Forward 1     3 and 4    
Forward 2     3 and 5    
Forward 3     3 and 6    
Forward 4     1 and 6    
Reverse 1     2 and 4    
Reverse 2     2 and 5    
Reverse 3     2 and 6    
( 1 ) This number is used in order to identify the solenoids in the manual.This diagnostic code is associated with transmission solenoid 3.FMI 05 is recorded when the transmission electronic control module senses an incomplete circuit. The solenoid's circuit is incomplete.Test Step 1. CHECK THE HARNESS FOR AN OPEN.
Turn the key start switch to the OFF position.
Disconnect the machine harness from the control module.
Measure the resistance between contact 39 and contact 33.Expected Result:The resistance is between 30 ohms and 65 ohms.Results:
YES - The resistance is between 30 ohms and 65 ohms. The sensor is operating properly. Inspect the harness connector and inspect the contacts. Verify that the diagnostic code is present. If the code is present, the transmission electronic control module has failed. Repair: Replace the transmission electronic control module. Refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace". Clear the diagnostic code. Stop.
NO - The resistance is not between 30 ohms and 65 ohms. The machine harness has failed or the solenoid has failed. Repair: Repair the harness or replace the harness and/or the solenoid. Clear the diagnostic code. Stop.
Parts control Caterpillar catalog:
7X1370
CONTROL GP-
Caterpillar
Caterpillar
7X1201
CONTROL GP-
Caterpillar
Caterpillar
7X1194
CONTROL AS
Caterpillar
Caterpillar
7X1066
CONTROL GP
Caterpillar
Caterpillar
7W7771
CONTROL G
Caterpillar
Caterpillar
7V9155
CONTROL G-GOV
Caterpillar
Caterpillar
7X4376
CONTROL BOX MT
Caterpillar
Caterpillar
7X4374
CONTROL BOX
Caterpillar
Caterpillar
7X4301
CONTROL
Caterpillar
Caterpillar
7X4191
CONTROL HANDLE
Caterpillar
Caterpillar
7X4152
CONTROL PANEL
Caterpillar
Caterpillar
7X4002
CONTROL PANEL
Caterpillar
Caterpillar