8T9882 CONTROL GP-ELECTRONIC Caterpillar parts
3208, 3304, 3304B, 3306, 3406B, 3408, 3412, 3412C, 3508, 3508B, 3512, 3512B, 3516, 3516B, PM3508, PM3512, PM3516
Rating:
Alternative (cross code) number:
CA8T9882
8T-9882
8T9882
CA8T9882
8T-9882
8T9882
Weight: 7 pounds 3 kg.
GEN SET ENGINE, POWER MODULE,
This part in 7 request:
Show.
This information for suppliers only!
2024-06-18
2024-01-11
2022-05-03
2021-12-16
2021-01-28
2019-09-26
2019-09-26
Compatible equipment models: 8T9882:
Information:
Removal Procedure
Start By:
Connect the steering frame lock. Refer to Disassembly and Assembly, "Steering Frame Lock - Separate and Connect".
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products.Dispose of all fluids according to local regulations and mandates.
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
Open the engine hood.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g00347632
Disconnect electrical connectors (1) .
Illustration 2 g00347633
Remove bolt (3). Remove hose assemblies (2) .
Illustration 3 g00347634
Illustration 4 g00347635
Loosen bolts (5) and (7). Move refrigerant compressor (4) toward the engine.
Remove V-belt (6) from refrigerant compressor (4) .
Remove bolt (5), bolt (7), and the nuts.
Remove refrigerant compressor (4) .Installation Procedure
Illustration 5 g00347635
Illustration 6 g00347634
Install refrigerant compressor (4) .
Install bolt (7), bolt (5), and the nuts. Do not tighten bolts (7) and (5) at this time.
Install V-belt (6) on refrigerant compressor (4) .
Adjust the tension of V-belt (6) .Note: Check the V-belt tension. Use a Kent Moore Company BT-33-109 gauge. The correct tension for a new V-belt is 534 22 N (120 5 lb). The correct tension for a used V-belt is 400 44 N (90 10 lb).
Tighten bolts (7) and (5) .
Illustration 7 g00347633
Install hose assemblies (2). Install bolt (3) .
Illustration 8 g00347632
Connect electrical connectors (1) .
Evacuate the air conditioner system. Charge the air conditioner system. The correct charge is 1.8 kg (4 lb). Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for
Start By:
Connect the steering frame lock. Refer to Disassembly and Assembly, "Steering Frame Lock - Separate and Connect".
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products.Dispose of all fluids according to local regulations and mandates.
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
Open the engine hood.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g00347632
Disconnect electrical connectors (1) .
Illustration 2 g00347633
Remove bolt (3). Remove hose assemblies (2) .
Illustration 3 g00347634
Illustration 4 g00347635
Loosen bolts (5) and (7). Move refrigerant compressor (4) toward the engine.
Remove V-belt (6) from refrigerant compressor (4) .
Remove bolt (5), bolt (7), and the nuts.
Remove refrigerant compressor (4) .Installation Procedure
Illustration 5 g00347635
Illustration 6 g00347634
Install refrigerant compressor (4) .
Install bolt (7), bolt (5), and the nuts. Do not tighten bolts (7) and (5) at this time.
Install V-belt (6) on refrigerant compressor (4) .
Adjust the tension of V-belt (6) .Note: Check the V-belt tension. Use a Kent Moore Company BT-33-109 gauge. The correct tension for a new V-belt is 534 22 N (120 5 lb). The correct tension for a used V-belt is 400 44 N (90 10 lb).
Tighten bolts (7) and (5) .
Illustration 7 g00347633
Install hose assemblies (2). Install bolt (3) .
Illustration 8 g00347632
Connect electrical connectors (1) .
Evacuate the air conditioner system. Charge the air conditioner system. The correct charge is 1.8 kg (4 lb). Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for
Caterpillar parts catalog:
Parts control Caterpillar catalog:
1180175
CONTROL GP-EMCP ELECTRONIC
3126B, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C, C-12, C15, C18, C27, C32, C9, G3304, G3306, G3306B, G3406, G34...
3126B, 3208, 3304, 3304B, 3306, 3306B, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C, C-12, C15, C18, C27, C32, C9, G3304, G3306, G3306B, G3406, G34...
1610797
CONTROL AS-GOVERNOR
3412, 3412C, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C280-12, C280-16, C280-6, C280-8, C9, G3406, G3606, G3608, G3612, G3616, PM3412, PP3516
3412, 3412C, 3456, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C280-12, C280-16, C280-6, C280-8, C9, G3406, G3606, G3608, G3612, G3616, PM3412, PP3516
1315453
CONTROL AS-ELECTRONIC GOVERNOR
3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, 3516C, C15, C18, G3304, G3306, G3306B, G3406, G3408, G3408B, G3412, G3508, G...
3208, 3304, 3304B, 3306, 3306B, 3406, 3406B, 3406C, 3408, 3408C, 3412, 3412C, 3508, 3508B, 3508C, 3512, 3512B, 3516, 3516B, 3516C, C15, C18, G3304, G3306, G3306B, G3406, G3408, G3408B, G3412, G3508, G...
2567512
CONTROL GP-COMMUNICATION
3176B, 3176C, 3196, 3406E, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, C175-16, C18, C280-12, C280-16, CG137-12, G3406, G3408, G3408C, G3412, G3508, G3508B, G3512, G3512B, G3512E, G3516, G3516B, G...
3176B, 3176C, 3196, 3406E, 3508B, 3508C, 3512, 3512B, 3512C, 3516B, 3516C, C175-16, C18, C280-12, C280-16, CG137-12, G3406, G3408, G3408C, G3412, G3508, G3508B, G3512, G3512B, G3512E, G3516, G3516B, G...
4W5392
CONTROL AS-GOVERNOR
3114, 3208, 3406, 3406B, 3408, 3508, 3512, 3516, 3606, 3608, 3612, 3616, SR4
3114, 3208, 3406, 3406B, 3408, 3508, 3512, 3516, 3606, 3608, 3612, 3616, SR4
1373399
CONTROL GP-ELECTRONIC
3412, 3412C
3412, 3412C
1373405
CONTROL GP-ELECTRONIC
3412, 3412C
3412, 3412C
2210785
CONTROL-ELECTRONIC
PM3508, PM3512, PM3516, PMG3516
PM3508, PM3512, PM3516, PMG3516
2901244
CONTROL UNIT
PM3516
PM3516
1794396
CONTROL AS
3508B
3508B
8N0408
CONTROL ASSEM.
3406, 3412, 3512
3406, 3412, 3512
4W1461
CONTROL AS-VALVE
3208, 3304, 3306, 3406, 3406B, 3412, 3412C, G3306, G3408, G3412, SR4
3208, 3304, 3306, 3406, 3406B, 3412, 3412C, G3306, G3408, G3412, SR4
9W2126
CONTROL GP
3208, 3304, 3304B, 3306, 3406B, 3408, 3412, 3412C, 3508, 3512, 3516
3208, 3304, 3304B, 3306, 3406B, 3408, 3412, 3412C, 3508, 3512, 3516
8T9881
CONTROL GP-ELECTRONIC
3208, 3304, 3304B, 3306, 3406B, 3408, 3412, 3412C, 3508, 3512, 3516
3208, 3304, 3304B, 3306, 3406B, 3408, 3412, 3412C, 3508, 3512, 3516
3H4630
CONTROL GROUP
D337
D337
2N1274
CONTROL (vernier)
3160, 3192, 3208, 7271
3160, 3192, 3208, 7271
2N9800
CONTROL ASSEM.
3406, D348, D349, D399
3406, D348, D349, D399
1259954
CONTROL AS
3508, 3512, 3516, 3516B
3508, 3512, 3516, 3516B
1445572
CONTROL AS-SYNCHRONIZE
3412, 3508, 3508B, 3512, 3512B, 3516, 3516B, G3516, PM3508, PM3512, PM3516, PMG3516
3412, 3508, 3508B, 3512, 3512B, 3516, 3516B, G3516, PM3508, PM3512, PM3516, PMG3516
1175062
CONTROL-ELECTRONIC
3408, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, G3406, G3408, G3412, G3516, PM3412, PM3508, PM3512, PM3516
3408, 3412, 3412C, 3456, 3508, 3508B, 3512, 3512B, 3516, 3516B, G3406, G3408, G3412, G3516, PM3412, PM3508, PM3512, PM3516
4W5392
CONTROL AS-GOVERNOR
3114, 3208, 3406, 3406B, 3408, 3508, 3512, 3516, 3606, 3608, 3612, 3616, SR4
3114, 3208, 3406, 3406B, 3408, 3508, 3512, 3516, 3606, 3608, 3612, 3616, SR4
4W5393
CONTROL AS-GOVERNOR
3406, 3406B, 3408, 3412, G3408, G3408B, G3412, G3508, G3512, G3516, G399
3406, 3406B, 3408, 3412, G3408, G3408B, G3412, G3508, G3512, G3516, G399
8S5179
CONTROL GP-GOVERNOR
3408, 3412, 983
3408, 3412, 983