8Y7598 CONTROL GP-TRANSMISSION Caterpillar parts
910E, IT12B, IT14F
Rating:
Alternative (cross code) number:
CA8Y7598
8Y-7598
8Y7598
CA8Y7598
8Y-7598
8Y7598
Weight: 1 pounds 0 kg.
COMPACT WHEEL LOADER, INTEGRATED TOOLCARRIER,
Compatible equipment models: 8Y7598:
Information:
"Digital Input Configuration"
Illustration 1 g01361917
"Digital Input Configuration" Screen
Table 1
Digital Input 1, 2, 3, or 4
Sensor Definition Configuration Notes
"Digital Sensor Input 1, 2, 3, or 4 Configuration Type" The "Digital Sensor Input 1, 2, 3, or 4 Configuration Type" parameter defines whether a sensor is attached and, if attached, the state of the switch contacts under normal operating conditions (Normally Open or Normally Closed). "Not Installed": The user cannot set the sensor to "Not Installed". No sensor attached to the input.
The user can set the type of sensor by the following methods:
"Not Configured": Sensor may be attached to the input but not in use.
"Normally Closed": Sensor is at a closed (or low) state under normal operating conditions.
"Normally Open": Sensor is at an open (or high) state under normal operating conditions. The user cannot set the sensor to "Not Installed". "Not Installed" is the factory default.
"Digital Input 1, 2, 3, or 4 Monitoring Condition" Defines the monitoring condition for the digital input. If the digital input is in the alarm state (opposite the normal state) as specified in "Digital Sensor Input 1, 2, 3, or 4 Type Configuration", for the delay time specified in "Digital Sensor Input 1, 2, 3, or 4 Delay Time", while the "Digital Input 1, 2, 3, or 4 Monitoring Condition" is true, an event is recorded and sent to the Equipmentmanager application. Set for the desired monitoring condition as follows:
All Conditions: Will monitor input without regard to key position or engine status.
Key Off/Engine Off. Will monitor the digital input when key is OFF and engine is not running.
Key On/Engine OFF: Will monitor the digital input when key is ON and engine is not running.
Key On/Engine On: Will monitor input when key is ON and engine is running. "All Conditions" is the factory default.
With key Off/Engine Off, status changes will only be monitored when the PL300 wakes up for scheduled reports. An Input on these switches will not trigger the PL300 to “wake up”.
"Digital Sensor Input 1, 2, 3, or 4 Description" The "Digital Sensor Input 1, 2, 3, or 4 Description" parameter is a 24 character field used to describe what the sensor is monitoring. This value is used in the office software to display the sensor status. Enter a maximum of 24 characters for the description of the digital sensor input, for example "TRACK TENSION SENSOR". The default is "DIGITAL INPUT 1, 2, 3, or 4".
"Digital Sensor Input 1, 2, 3, or 4 Delay Time" Defines the delay time before an alarm condition is recorded. If the digital input is in the alarm state (opposite the normal state) as specified in "Digital Sensor Input 1, 2, 3, or 4 Type Configuration", for the delay time specified in "Digital Sensor Input 1, 2, 3, or 4 Delay Time", while the "Digital Input 1, 2, 3, or 4 Monitoring Condition" is true, an event is recorded and sent to the Equipmentmanager application. It is important to set this time correctly so spurious alarms are not set or
Illustration 1 g01361917
"Digital Input Configuration" Screen
Table 1
Digital Input 1, 2, 3, or 4
Sensor Definition Configuration Notes
"Digital Sensor Input 1, 2, 3, or 4 Configuration Type" The "Digital Sensor Input 1, 2, 3, or 4 Configuration Type" parameter defines whether a sensor is attached and, if attached, the state of the switch contacts under normal operating conditions (Normally Open or Normally Closed). "Not Installed": The user cannot set the sensor to "Not Installed". No sensor attached to the input.
The user can set the type of sensor by the following methods:
"Not Configured": Sensor may be attached to the input but not in use.
"Normally Closed": Sensor is at a closed (or low) state under normal operating conditions.
"Normally Open": Sensor is at an open (or high) state under normal operating conditions. The user cannot set the sensor to "Not Installed". "Not Installed" is the factory default.
"Digital Input 1, 2, 3, or 4 Monitoring Condition" Defines the monitoring condition for the digital input. If the digital input is in the alarm state (opposite the normal state) as specified in "Digital Sensor Input 1, 2, 3, or 4 Type Configuration", for the delay time specified in "Digital Sensor Input 1, 2, 3, or 4 Delay Time", while the "Digital Input 1, 2, 3, or 4 Monitoring Condition" is true, an event is recorded and sent to the Equipmentmanager application. Set for the desired monitoring condition as follows:
All Conditions: Will monitor input without regard to key position or engine status.
Key Off/Engine Off. Will monitor the digital input when key is OFF and engine is not running.
Key On/Engine OFF: Will monitor the digital input when key is ON and engine is not running.
Key On/Engine On: Will monitor input when key is ON and engine is running. "All Conditions" is the factory default.
With key Off/Engine Off, status changes will only be monitored when the PL300 wakes up for scheduled reports. An Input on these switches will not trigger the PL300 to “wake up”.
"Digital Sensor Input 1, 2, 3, or 4 Description" The "Digital Sensor Input 1, 2, 3, or 4 Description" parameter is a 24 character field used to describe what the sensor is monitoring. This value is used in the office software to display the sensor status. Enter a maximum of 24 characters for the description of the digital sensor input, for example "TRACK TENSION SENSOR". The default is "DIGITAL INPUT 1, 2, 3, or 4".
"Digital Sensor Input 1, 2, 3, or 4 Delay Time" Defines the delay time before an alarm condition is recorded. If the digital input is in the alarm state (opposite the normal state) as specified in "Digital Sensor Input 1, 2, 3, or 4 Type Configuration", for the delay time specified in "Digital Sensor Input 1, 2, 3, or 4 Delay Time", while the "Digital Input 1, 2, 3, or 4 Monitoring Condition" is true, an event is recorded and sent to the Equipmentmanager application. It is important to set this time correctly so spurious alarms are not set or
Caterpillar SIS machinery equipment:
Caterpillar SIS
910F WHEEL LOADER 1SF01104-UP (MACHINE) POWERED BY 3114 ENGINE »
8Y-7598
CONTROL GP-TRANSMISSION
910F WHEEL LOADER 1SF01104-UP (MACHINE) POWERED BY 3114 ENGINE »
8Y-7598
CONTROL GP-TRANSMISSION
IT12F Integrated Toolcarrier 1KF00820-UP (MACHINE) POWERED BY 3114 Engine »
8Y-7598
CONTROL GP-TRANSMISSION
IT12F Integrated Toolcarrier 1KF00820-UP (MACHINE) POWERED BY 3114 Engine »
8Y-7598
CONTROL GP-TRANSMISSION
IT14F TOOLCARRIER 4EL00001-UP (MACHINE) POWERED BY 3114 ENGINE »
8Y-7598
CONTROL GP-TRANSMISSION
Caterpillar parts catalog:
Parts control Caterpillar catalog:
3E7844
CONTROL GP-LIFT KICKOUT
910E, 910G, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 938F, 938G, 938G II, 938H, 950G, 950G II, 962G, 962G II, 966G, 966G II, 972G, 972G II, 980G II, 980H, 988F, 988F II, 99...
910E, 910G, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 938F, 938G, 938G II, 938H, 950G, 950G II, 962G, 962G II, 966G, 966G II, 972G, 972G II, 980G II, 980H, 988F, 988F II, 99...
3E7843
CONTROL GP-BUCKET POSITIONER
416C, 420D, 420E, 426C, 428C, 428D, 428E, 430D, 430E, 432D, 432E, 434E, 436C, 438C, 438D, 442D, 442E, 444E, 902, 906, 908, 910E, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 93...
416C, 420D, 420E, 426C, 428C, 428D, 428E, 430D, 430E, 432D, 432E, 434E, 436C, 438C, 438D, 442D, 442E, 444E, 902, 906, 908, 910E, 914G, 918F, 924F, 924G, 924GZ, 924H, 924HZ, 928F, 928G, 928HZ, 930G, 93...
1162025
CONTROL GP-POSITION
910E, 914G, 928G, 938G, 950G, 962G, 966G, 972G, IT12B, IT14G, IT28G, IT38G, IT62G
910E, 914G, 928G, 938G, 950G, 962G, 966G, 972G, IT12B, IT14G, IT28G, IT38G, IT62G
3W8008
CONTROL GP-SERVICE BRAKE
910E, IT12B
910E, IT12B
3W8023
CONTROL GP-STEERING
910E, IT12B, IT14B
910E, IT12B, IT14B
8E5526
CONTROL GP-TRANSMISSION HYD
910E, 918F, IT12B, IT14F
910E, 918F, IT12B, IT14F
8Y8591
CONTROL GP-BRAKE
910E, IT12B
910E, IT12B
1707670
CONTROL AS
3114, 446B, 446D, 924F, IT12B, IT24F
3114, 446B, 446D, 924F, IT12B, IT24F
1011704
CONTROL AS
910E, IT12B
910E, IT12B
1060333
CONTROL AS
910E, IT12B
910E, IT12B
1809711
CONTROL GP-TRANSMISSION
TH103, TH62, TH63, TH82, TH83
TH103, TH62, TH63, TH82, TH83
2093129
CONTROL GP-GRADE & SLOPE
AP-1000B, AP-1055B, AP-900B, BG-245C
AP-1000B, AP-1055B, AP-900B, BG-245C
3801969
CONTROL GP-DIRECTION & SPEED
CP-68B, CP-74B, CS-56B, CS-66B
CP-68B, CP-74B, CS-56B, CS-66B
2872054
CONTROL GP-PILOT OPERATED HYD
928H, IT28G
928H, IT28G
2Y5534
CONTROL GP-STEERING
966C, 966R
966C, 966R
5G4866
CONTROL GP-GOV & TRANSMISSION
931B, 931C, 931C II, 935C II, D3B, D4B
931B, 931C, 931C II, 935C II, D3B, D4B
9EP5903
CONTROL AR-AUTODIG
R1700 II
R1700 II
9EP0238
CONTROL GP-MONITOR
R1700 II
R1700 II
1626823
CONTROL & MTG GP-ENGINE ELEK
5110B, 651E, 657E, 844, 990 II, D10R, PM-565B
5110B, 651E, 657E, 844, 990 II, D10R, PM-565B
1380241
CONTROL GP-STEERING
902, 906, 908
902, 906, 908