Table 1
Battery Electrolyte Level    
Battery    Interval    
Conventional     100 Hours    
Low Maintenance     250 Hours    
Maintenance Free     No Interval    Tighten the battery retainers on all of the batteries. Tighten the battery retainers at every 1000 hours.Check the following areas at a minimum interval of 1000 hours. Check the following areas more frequently during adverse conditions.
Illustration 1 g00954685
The battery access cover is located on the right side of the rear frame. Open the battery access cover.
Illustration 2 g00953914
Clean the battery surface with a clean cloth.
Disconnect all battery cables from the batteries.Reference: For more information on disconnecting the battery cables, refer to the Operation and Maintenance Manual, "Battery, Battery Cable or Battery Disconnect Switch - Replace" for the machine that is being serviced.
Clean the battery cables and the battery posts. Coat the battery posts with 1P-0808 Multipurpose Grease or petroleum jelly.
Connect the battery cables to the batteries.Reference: For more information on connecting the battery cables, refer to the Operation and Maintenance Manual, "Battery, Battery Cable or Battery Disconnect Switch - Replace" for the machine that is being serviced.
Coat the terminals with 1P-0808 Multipurpose Grease or petroleum jelly. Then, install the post cover.
For conventional batteries and batteries of low maintenance, follow these additional instructions:
Inspect the battery electrolyte level in each battery cell. A maintenance free battery does not require inspection.
Maintain the level of the distilled water to the bottom of the filler openings. If distilled water is not available, use clean drinking water.
A battery should not require more than 30 cc (1 ounce) of water per cell per week. This requirement should exist with the proper charging rate and with a moderate climate.
In extreme temperatures, check the water in the cells weekly. Cell water usage could be higher in extreme temperatures.