1754998 CONVERTER-SIGNAL Caterpillar parts
3126B, 3412E, 3508B, 3508C, 3512B, 3512C, 3516B, 3516C, C-10, C-12, C-15, C-16, C-9, C15, C175-16, C18, C27, C280-12, C280-16, C280-6, C280-8, C32
Rating:
Alternative (cross code) number:
CA1754998
175-4998
1754998
CA1754998
175-4998
1754998
Weight: 0.39 pounds 0 kg.
GEN SET ENGINE, PETROLEUM GEN SET,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
WZCNLXLX Converter 175-4998 1754998 CONVERTER-SIGNAL for Caterpillar CAT Generator Set C15 C18 C32 Engine
WZCNLXLX Item Name:Converter || Item Number:175-4998 1754998 || Application:for Caterpillar CAT 3126B, 3412E, 3508B, 3508C, 3512B, 3512C, 3516B, 3516C, C-10, C-12, C-15, C-16, C-9, C15, C175-16, C18, C27, C280-12, C280-16, C280-6, C280-8, C32 Engine || Note: If you are unsure if the product is suitable.In order not to delay your use of the parts, please provide your engine nameplate or serial number and part number, and we will help you confirm if it is suitable. To avoid unnecessary returns, please check the product image and part number to ensure it is the product you want. || Tip: Please contact us - we are a professional sales team and we have many products to offer to you. Many buyers are very satisfied with our service. You can get first-class products and high-quality services from us, believe me, you will have a pleasant shopping experience here.
WZCNLXLX Item Name:Converter || Item Number:175-4998 1754998 || Application:for Caterpillar CAT 3126B, 3412E, 3508B, 3508C, 3512B, 3512C, 3516B, 3516C, C-10, C-12, C-15, C-16, C-9, C15, C175-16, C18, C27, C280-12, C280-16, C280-6, C280-8, C32 Engine || Note: If you are unsure if the product is suitable.In order not to delay your use of the parts, please provide your engine nameplate or serial number and part number, and we will help you confirm if it is suitable. To avoid unnecessary returns, please check the product image and part number to ensure it is the product you want. || Tip: Please contact us - we are a professional sales team and we have many products to offer to you. Many buyers are very satisfied with our service. You can get first-class products and high-quality services from us, believe me, you will have a pleasant shopping experience here.
Register For Sailing Lessons Write On Me Red Folding Coroplast A-Frame with Double-Sided 23in x23in
Work House Signs Durable Folding A-Frame Sign – Made from industrial-grade coroplast (corrugated plastic) that is lightweight, waterproof, and UV-resistant, built to handle indoor or outdoor use. || Double-Sided Display – Features two 23"x23" sign panels for maximum visibility from both directions, making it ideal for sidewalk advertising, storefront signage, open house signs, and event promotions. || Lightweight & Portable – Easy to carry, set up, and fold flat for compact storage or transport; perfect for temporary business signs, trade shows, and real estate marketing. || Versatile Business Signage – Use as a sidewalk sign, retail display board, restaurant menu stand, or event directional sign—a cost-effective solution for high-impact advertising. || Professional Presentation – Clean, modern design delivers a polished look that draws attention to your message, ideal for small businesses, restaurants, boutiques, and service providers.
Work House Signs Durable Folding A-Frame Sign – Made from industrial-grade coroplast (corrugated plastic) that is lightweight, waterproof, and UV-resistant, built to handle indoor or outdoor use. || Double-Sided Display – Features two 23"x23" sign panels for maximum visibility from both directions, making it ideal for sidewalk advertising, storefront signage, open house signs, and event promotions. || Lightweight & Portable – Easy to carry, set up, and fold flat for compact storage or transport; perfect for temporary business signs, trade shows, and real estate marketing. || Versatile Business Signage – Use as a sidewalk sign, retail display board, restaurant menu stand, or event directional sign—a cost-effective solution for high-impact advertising. || Professional Presentation – Clean, modern design delivers a polished look that draws attention to your message, ideal for small businesses, restaurants, boutiques, and service providers.
This part in 6 request:
Show.
This information for suppliers only!
2023-07-26
2022-12-15
2022-11-22
2022-05-23
2019-08-22
2019-08-22
Compatible equipment models: 1754998:
Information:
All SR 4 Generators With VR3 Voltage RegulatorsThe VR3 Voltage Regulator contains parts which have the ability to "sense" voltage. The "sensing" is performed at the input of the VR3 Voltage Regulator. Under certain conditions, these parts may fail and cause a loss of voltage "sensing" ability. If this happens, the generator output voltage will go to maximum.
This potential problem exists with most voltage regulator manufacturers. Once the sensing voltage is lost, the voltage regulator "sees" this as a low voltage condition. The voltage regulator forces the generator to try and overcome the low voltage condition in an attempt to bring the voltage back to normal. This causes the generator to switch to a full output condition and a possible overvoltage condition is created.
If the sensing is lost at the input of the voltage regulator, then the load connected to the generator output may be unable to tolerate the overvoltage condition. Suitable overvoltage protection must be provided to disconnect the load from the generator.
The following demonstrates a typical condition and response to overvoltage conditions for the VR3 Voltage Regulator.
Self-Excited Regulators (SE) (see Illustration 1)
Mode 1: Failure of any component such that the regulator "sees" a loss of sensing at lead 20 or 24.
Result: Output of the regulator will be shut off and the generator output voltage will be at minimum.
Mode 2: Failure of any component such that the regulator "sees" a loss of sensing at lead 22.
Result: The regulator will go to "full field" resulting in the generator output voltage going to maximum. This will normally result in a fuse failure (opening), turning off the regulator. If the fuse(s) should fail to open, the overvoltage condition will continue for approximately 12 seconds. At this time, the over-excitation limit built into the regulator will turn the regulator off.
If sensing leads 20 or 24 are lost, generator output will be at minimum for the VR4 Voltage Regulator ONLY.
Illustration 1. Self-Excited Regulator (SE). Droop transformer (CT1) and droop rheostat (R1) may or may not be supplied. The exciter field is L1.Permanent Magnet Excited Regulators (PM) (see Illustration 2)
Mode 1: Failure of any component such that the regulator "sees" a loss of sensing at lead 20, 22, or 24.
Result: The regulator will go to "full field" resulting in the generator output voltage going to maximum. This condition will continue for approximately 12 seconds. At this time, the over-excitation limit built into the regulator will turn the regulator off.
Mode 2: Failure of any component such that the regulator "sees" a loss of input from the PM exciter on leads 11, 12, or 13.
Result: If one lead is lost, generator output capability will be reduced. Generator output voltage will drop if capability is exceeded. If two or more leads are lost, generator output voltage will be at minimum.
Illustration 2. Permanent Magnet Excited Regulator (PM). Droop transformer (CT1) and droop rheostat (R1) may or may not be supplied. The exciter field is L1, the stator is L5.
This potential problem exists with most voltage regulator manufacturers. Once the sensing voltage is lost, the voltage regulator "sees" this as a low voltage condition. The voltage regulator forces the generator to try and overcome the low voltage condition in an attempt to bring the voltage back to normal. This causes the generator to switch to a full output condition and a possible overvoltage condition is created.
If the sensing is lost at the input of the voltage regulator, then the load connected to the generator output may be unable to tolerate the overvoltage condition. Suitable overvoltage protection must be provided to disconnect the load from the generator.
The following demonstrates a typical condition and response to overvoltage conditions for the VR3 Voltage Regulator.
Self-Excited Regulators (SE) (see Illustration 1)
Mode 1: Failure of any component such that the regulator "sees" a loss of sensing at lead 20 or 24.
Result: Output of the regulator will be shut off and the generator output voltage will be at minimum.
Mode 2: Failure of any component such that the regulator "sees" a loss of sensing at lead 22.
Result: The regulator will go to "full field" resulting in the generator output voltage going to maximum. This will normally result in a fuse failure (opening), turning off the regulator. If the fuse(s) should fail to open, the overvoltage condition will continue for approximately 12 seconds. At this time, the over-excitation limit built into the regulator will turn the regulator off.
If sensing leads 20 or 24 are lost, generator output will be at minimum for the VR4 Voltage Regulator ONLY.
Illustration 1. Self-Excited Regulator (SE). Droop transformer (CT1) and droop rheostat (R1) may or may not be supplied. The exciter field is L1.Permanent Magnet Excited Regulators (PM) (see Illustration 2)
Mode 1: Failure of any component such that the regulator "sees" a loss of sensing at lead 20, 22, or 24.
Result: The regulator will go to "full field" resulting in the generator output voltage going to maximum. This condition will continue for approximately 12 seconds. At this time, the over-excitation limit built into the regulator will turn the regulator off.
Mode 2: Failure of any component such that the regulator "sees" a loss of input from the PM exciter on leads 11, 12, or 13.
Result: If one lead is lost, generator output capability will be reduced. Generator output voltage will drop if capability is exceeded. If two or more leads are lost, generator output voltage will be at minimum.
Illustration 2. Permanent Magnet Excited Regulator (PM). Droop transformer (CT1) and droop rheostat (R1) may or may not be supplied. The exciter field is L1, the stator is L5.
Caterpillar SIS machinery equipment:
Caterpillar SIS
3516C Petroleum Engine NG300001-UP »
175-4998
CONVERTER-SIGNAL
3516E Marine Engine MD500001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine MD300001-UP »
175-4998
CONVERTER-SIGNAL
3516E Marine Engine MRY00001-UP »
175-4998
CONVERTER-SIGNAL
3516E Marine Engine MRN00001-UP »
175-4998
CONVERTER-SIGNAL
3516E Marine Engine MRC00001-UP »
175-4998
CONVERTER-SIGNAL
3516E Marine Engine MR900001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine MR800001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine MR700001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine MR400001-UP »
175-4998
CONVERTER-SIGNAL
C175-16 Petroleum Engine P6N00001-UP »
175-4998
CONVERTER-SIGNAL
C175–16 Petroleum Engine P6R00001-UP »
175-4998
CONVERTER-SIGNAL
3516C Generator Set PYA00001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine MR200001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine MR300001-UP »
175-4998
CONVERTER-SIGNAL
C175–16 Petroleum Engine P6P00001-UP »
175-4998
CONVERTER-SIGNAL
3516E Marine Engine SW300001-UP »
175-4998
CONVERTER-SIGNAL
3516E Marine Engine SW400001-UP »
175-4998
CONVERTER-SIGNAL
3516E Marine Engine SW500001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine SY400001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine SY500001-UP »
175-4998
CONVERTER-SIGNAL
3516E Marine Engine SWD00001-UP »
175-4998
CONVERTER-SIGNAL
3516E Marine Engine SWK00001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine SY700001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine SY800001-UP »
175-4998
CONVERTER-SIGNAL
3512E Marine Engine SY900001-UP »
175-4998
CONVERTER-SIGNAL
3412E Industrial Engine 4CR00001-UP »
175-4998
CONVERTER-SIGNAL
3412E Industrial Engine BDT00001-UP »
175-4998
CONVERTER-SIGNAL
C-16 Industrial Engine BFM00001-UP »
175-4998
CONVERTER-SIGNAL
C175–16 Petroleum Engine P6L00001-UP »
175-4998
CONVERTER-SIGNAL
3512C Petroleum Engine LN500001-UP »
175-4998
CONVERTER-SIGNAL
C175–16 Engine P5P00001-UP »
175-4998
CONVERTER-SIGNAL
Cat SIS web machinery list:
Parts converter Caterpillar catalog:
2490470
CONVERTER GP-CATALYTIC
3512, 3512B, 3516B
3512, 3512B, 3516B
2490473
CONVERTER GP-CATALYTIC
3516B, G3516B, G3606B
3516B, G3516B, G3606B
2008972
CONVERTER GP-ELECTRICAL
3508B, 3512, 3512B, 3516, 3516B, 3516C, G3512E, G3520C, G3520E, SR4, SR4BHV
3508B, 3512, 3512B, 3516, 3516B, 3516C, G3512E, G3520C, G3520E, SR4, SR4BHV
1278853
CONVERTER GP-ELECTRICAL
3126B, 3176B, 3176C, 3196, 3406E, 3412, C-10, C-12, C-15, C-16, C-9, C11, C13, C15, C18, C7, C9, CX31-C13I, CX31-C15I, CX31-C9I, CX35-P800, SBF214, SUF557, TH31-E61, TH35-C11I, TH35-C13I, TH35-C15I
3126B, 3176B, 3176C, 3196, 3406E, 3412, C-10, C-12, C-15, C-16, C-9, C11, C13, C15, C18, C7, C9, CX31-C13I, CX31-C15I, CX31-C9I, CX35-P800, SBF214, SUF557, TH31-E61, TH35-C11I, TH35-C13I, TH35-C15I
1459929
CONVERTER GP-ELECTRICAL
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C
1807385
CONVERTER GP-ELECTRICAL
3508B, 3508C, 3512B, 3512C, 3516B
3508B, 3508C, 3512B, 3512C, 3516B
2560328
CONVERTER AS
3512, 3512B, 3516B
3512, 3512B, 3516B
1413284
CONVERTER-VOLTAGE
3508, 3508B, 3512, 3512B, 3516, 3516B
3508, 3508B, 3512, 3512B, 3516, 3516B
2560331
CONVERTER AS
3516B, G3516B, G3606B
3516B, G3516B, G3606B
2560327
CONVERTER AS
3508B
3508B
2741978
CONVERTER AS-SIGNAL
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C175-16, C175-20, C27, C32
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C175-16, C175-20, C27, C32
3594285
CONVERTER GP-ELECTRICAL
324D L, 329D L, 336D L
324D L, 329D L, 336D L
1451297
CONVERTER GP-ELECTRICAL
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 16H, 16H NA
120H, 120H ES, 120H NA, 12H, 12H ES, 12H NA, 135H, 135H NA, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 16H, 16H NA
6I9020
CONVERTER GP
D4H, D4H XL, D5H, D5H XL, D5M, D6H, D6H XL, D6H XR, D6M, D6R, D7H, D8N, D8R
D4H, D4H XL, D5H, D5H XL, D5M, D6H, D6H XL, D6H XR, D6M, D6R, D7H, D8N, D8R
2075947
CONVERTER GP-ELECTRICAL
924G, 924GZ, 924H, 924HZ, 928HZ, 930G, IT28G
924G, 924GZ, 924H, 924HZ, 928HZ, 930G, IT28G
2508379
CONVERTER GP-ELECTRICAL
844K, 854K, 990K, 992K, 993K, 994H
844K, 854K, 990K, 992K, 993K, 994H
3613136
CONVERTER GP-ELECTRICAL
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M
2405535
CONVERTER GP-ELECTRICAL
3054C, 3054E, 315C, AP-650B, AP-800D, CP-433E, CP-533E, CS-323C, CS-423E, CS-433E, CS-533E, M313C, M315C, PF-300C, PS-150C, PS-360C
3054C, 3054E, 315C, AP-650B, AP-800D, CP-433E, CP-533E, CS-323C, CS-423E, CS-433E, CS-533E, M313C, M315C, PF-300C, PS-150C, PS-360C
4P4789
CONVERTER GP-ELECTRICAL
3606, 3608, 3612, 3616
3606, 3608, 3612, 3616
1537725
CONVERTER GP-ELECTRICAL
3508, 3508B, 3512, 3512B, 3516, 3516B, PM3508, PM3512, PM3516
3508, 3508B, 3512, 3512B, 3516, 3516B, PM3508, PM3512, PM3516
2S6444
CONVERTER CONTROL VALVE GROUP
657B, 666, 824B, 825B, 826B, 834, 992
657B, 666, 824B, 825B, 826B, 834, 992
8R2950
CONVERTER GP-ELECTRICAL
910E, 916, 926A, 936, 936F, 950F, 966F, 980F, 980F II, IT12B, IT14B, IT18B, IT28B
910E, 916, 926A, 936, 936F, 950F, 966F, 980F, 980F II, IT12B, IT14B, IT18B, IT28B