1T0012 CONVERTER A. Caterpillar parts
Rating:
Alternative (cross code) number:
CA1T0012
1T-0012
1T0012
CA1T0012
1T-0012
1T0012
Weight: 1 pounds 0 kg.
Information:
Illustration 14 g02283536
Use the arrows to adjust the pressure. Confirm the pressure with the pressure gauge. Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", and "Pump Outlet Pressures".Cat Electronic Technician Procedure
The following procedure will allow the user to calibrate the variable relief valves using the Cat Electronic Technician.
Illustration 15 g02713701
Diagnostic connector for Cat Electronic Technician
Connect the Cat Electronic Technician to the diagnostic connector located behind the seat on the left side of the cab.
Illustration 16 g02713758
Start Cat Electronic Technician.
Illustration 17 g03592276
Select the ECM for "Machine Control".
Illustration 18 g03592557
Select "Calibrations" from the "Service" menu.
Illustration 19 g03593797
Highlight "PRV - Variable Relief Pressure Calibration" and click on the "Start" button in the lower left corner of the screen.
Illustration 20 g02724526
Select the variable relief valves to calibrate and press the "Begin" button.
Illustration 21 g02724528
Follow the instructions on the screen. Press "Next" button to continue through to the next step.
Press and hold the control input for activation of the work tool to the FULL ON position during the calibration.
Use the arrows to adjust the pressure until the pressure reading is at 10000 1000 kPa (1450 145 psi). Press the device for activation 3 times and release the device for activation 3 times for each adjustment.
Press the "NEXT" button when the pressure reading holds steady at 10000 1000 kPa (1450 145 psi) and no more adjustment is required.
Press and hold the control input for activation of the work tool to the FULL ON position during the calibration.
Use the arrows to adjust the pressure until the pressure reading is at 30000 1000 kPa (4351 145 psi). Press the device for activation 3 times and release the device for activation 3 times for each adjustment.
Press the "NEXT" button when the pressure reading holds steady at 30000 1000 kPa (4351 145 psi) and no more adjustment is required.
If the calibration was successful and no errors occurred, the display will indicate that the calibration is complete. Press the "Finish" button to exit or move on to the next calibration.
If the calibration failed, the calibration is not saved. Press the "Restart" button to try the calibration again or press the "Finish" button to exit or move on to the next calibration. Test Procedure
Confirm the calibration using the following procedure.
Illustration 22 g03593776
Select "Diagnostic Tests" from the "Diagnostics" menu.
Illustration 23 g03593817
Highlight "Variable Relief Valve Pressure Test" and click on the "Start" button in the lower left corner of the screen.
Illustration 24 g02727007
Select the test and press the "Begin" button.
Illustration 25 g02727008
Follow the instructions on the screen. Press "Start" button in the lower left corner to begin the test.
Use the arrows to adjust the pressure. Confirm the pressure with the pressure gauge.
Parts converter Caterpillar catalog:
1T0010
CONVERTER A.
Caterpillar
Caterpillar
1T0008
CONVERTER A.
Caterpillar
Caterpillar
1T0007
CONVERTER A.
Caterpillar
Caterpillar
1T0005
CONVERTER A.
Caterpillar
Caterpillar
1T0004
CONVERTER A.
Caterpillar
Caterpillar
1T0003
CONVERTER A.
Caterpillar
Caterpillar
1T0600
CONVERTER A.
Caterpillar
Caterpillar
1T0430
CONVERTER A.
Caterpillar
Caterpillar
1T0372
CONVERTER A
Caterpillar
Caterpillar
1T0362
CONVERTER G
Caterpillar
Caterpillar
1T0360
CONVERTER G.
Caterpillar
Caterpillar
1T0330
CONVERTER A
Caterpillar
Caterpillar