1286460 COOLER GP- Caterpillar parts
Rating:
Alternative (cross code) number:
CA1286460
128-6460
1286460
CA1286460
128-6460
1286460
Weight: 700 pounds 317 kg.
Information:
Illustration 1 g01128228
(11) Condenser (12) Condenser fan (13) Condenser fan motor (14) Resistor (16) Fan shroudThe condenser assembly contains condenser (11) , condenser fan motor (13) and resistor (14) .Condenser
When the refrigerant leaves the compressor, the refrigerant pressure is increased. The increased pressure of the refrigerant causes an increase in temperature of the refrigerant. Since the temperature of the refrigerant is high and the pressure of the refrigerant is high, the refrigerant leaves the compressor as a vapor. The refrigerant vapor enters the condenser.The refrigerant vapor must be converted into a liquid in order to increase the efficiency of the air conditioning system. In order to convert the refrigerant vapor into a liquid, the refrigerant must lose heat. As the high temperature, high pressure refrigerant vapor passes through the condenser, the condenser fins absorb heat from the refrigerant vapor. The condenser fins transfer the heat efficiently to the outside air.The temperature of the refrigerant and the pressure of the refrigerant decrease until the temperature of saturation is reached. When the temperature of the refrigerant vapor is equal to the temperature of saturation, the refrigerant becomes a high temperature, high pressure liquid. The temperature of saturation of the refrigerant depends on the pressure of the refrigerant. When the refrigerant is converted into a liquid, the refrigerant leaves the condenser and flows to the receiver-dryer.If the refrigerant is not cooled enough, the air inside the cab at the evaporator coil will not be cooled sufficiently. In order to prevent this situation, good ventilation must be provided. The condenser is in a location that is exposed to outside air. This will make cooling the refrigerant more efficient. Condenser Fan Motor
The condenser fan motor is located on fan shroud (16) . The fan shroud is located on the condenser. The fan motor works with the fan shroud in order to cool the condenser.Resistor
The speed of the condenser fan motor (13) is controlled at two stages by the pressure switches for the fan control.
Parts cooler Caterpillar catalog:
1281282
COOLER
Caterpillar
Caterpillar
1281238
COOLER
Caterpillar
Caterpillar
1270933
COOLER-OIL
Caterpillar
Caterpillar
1263796
COOLER AR-
Caterpillar
Caterpillar
1263791
COOLER AR-
Caterpillar
Caterpillar
1247833
COOLER AS
Caterpillar
Caterpillar
1348342
COOLER AS
Caterpillar
Caterpillar
1329502
COOLER GP
Caterpillar
Caterpillar
1328599
COOLER AS.-OIL
Caterpillar
Caterpillar
1328598
COOLER AS.-OIL
Caterpillar
Caterpillar
1312647
COOLER GP-OIL
Caterpillar
Caterpillar
1305229
COOLER-AIR
Caterpillar
Caterpillar