3850103 COOLER-COLD Caterpillar parts
Rating:
Alternative (cross code) number:
CA3850103
385-0103
3850103
CA3850103
385-0103
3850103
Weight: 28 pounds 12 kg.
Information:
Engines:
3606 (S/N: 8RB)
3608 (S/N: 6MC; 1ZD; 5PG; 8LL; 7WR)
3612 (S/N: NZA; 9RC; 9FR; 2NZ)
3616 (S/N: 1PD; 1FN)
The standard 3 phase voltages that are available have been changed for options that are driven by electric motors. The options that are affected include the following items: electric barring device, intermittent electric prelube, continuous prelube, jacket water heaters, oil heaters and combined heaters. The voltages that are available follow:
380 VAC at 60 Hz
400 VAC at 50 Hz
480 VAC at 60 HzThe electric motors that are used in these options have been sized so that the motors that are designed to operate at 400 VAC and 50 Hz can be operated at 380 VAC and 50 Hz. The motors that are designed to operate at 480 VAC and 60 Hz can be operated at 460 VAC and 60 Hz. The motors that are designed to operate at 380 VAC and 60 Hz must be operated at 380 VAC and 60 Hz.If any of the optional heaters are used at a voltage that is less than the rating, the output of heat from the heating elements will be reduced and the heater will run longer in order to maintain the temperature setpoint.
3606 (S/N: 8RB)
3608 (S/N: 6MC; 1ZD; 5PG; 8LL; 7WR)
3612 (S/N: NZA; 9RC; 9FR; 2NZ)
3616 (S/N: 1PD; 1FN)
The standard 3 phase voltages that are available have been changed for options that are driven by electric motors. The options that are affected include the following items: electric barring device, intermittent electric prelube, continuous prelube, jacket water heaters, oil heaters and combined heaters. The voltages that are available follow:
380 VAC at 60 Hz
400 VAC at 50 Hz
480 VAC at 60 HzThe electric motors that are used in these options have been sized so that the motors that are designed to operate at 400 VAC and 50 Hz can be operated at 380 VAC and 50 Hz. The motors that are designed to operate at 480 VAC and 60 Hz can be operated at 460 VAC and 60 Hz. The motors that are designed to operate at 380 VAC and 60 Hz must be operated at 380 VAC and 60 Hz.If any of the optional heaters are used at a voltage that is less than the rating, the output of heat from the heating elements will be reduced and the heater will run longer in order to maintain the temperature setpoint.
Parts cooler Caterpillar catalog:
3817236
COOLER GP-
Caterpillar
Caterpillar
3817228
COOLER GP-
Caterpillar
Caterpillar
3815643
COOLER GP-
Caterpillar
Caterpillar
3814954
COOLER GP-FUEL
Caterpillar
Caterpillar
3802894
COOLER AS-OIL
Caterpillar
Caterpillar
3802879
COOLER-OIL RTD
Caterpillar
Caterpillar
3894048
COOLER GP-
Caterpillar
Caterpillar
3894047
COOLER GP-
Caterpillar
Caterpillar
3891206
COOLER AR-
Caterpillar
Caterpillar
3879818
COOLER GP-EGR
Caterpillar
Caterpillar
3875462
COOLER GP-
Caterpillar
Caterpillar
3856175
COOLER-
Caterpillar
Caterpillar