4W5893 COOLER GP-ENGINE OIL Caterpillar parts
3126, 3508, 3508B, 3508C, 5130, 5130B, D11N, D11R, G3508, G3508B, PM3508
Rating:
Alternative (cross code) number:
CA4W5893
4W-5893
4W5893
CA4W5893
4W-5893
4W5893
GAS ENGINE, VEHICULAR ENGINE,
Compatible equipment models: 4W5893:
Information:
flooded, or filled with dirt.Note: Even with the best treatment and careful testing, the insulation of a generator that has been submerged may be damaged beyond repair.
When water pressure is used for cleaning purposes, the pressure of the water must not exceed 205 kPa (30 psi) otherwise damage to the equipment may occur.
Flush the unit with fresh warm water in order to remove all traces of salt and silt. Washing should continue until tests of the fresh water show the insulation to be free of salt.Note: Complete disassembly of the generator may be necessary, in order to accomplish a proper cleaning.Bake and dry the unit completely with externally applied heat before placing back into service. Refer to the procedure in "Drying" for more information.Note: If the generator is used in or near salty air and high humidity environments, special electric component cleaners and protectors are needed to prevent corrosion.Drying
Drying may be accomplished by external heat, internal heat, a combination of internal heat and external heat, or circulating current.
When using external heat to dry the generator, do not exceed 85° C (185° F) otherwise damage to the equipment may occur.
External heat is the most preferable method. Insulation drying time can vary from a few hours to several days, depending on moisture content and the process used for drying.Note: Drying sometimes does not produce the required results. The use of a qualified rebuild shop for drying and redipping of the generator may be necessary.
Illustration 3 g01697133
Typical curves of the resistance in the insulation that is drying
(3) Curve of the temperature in the windings
(4) Heat turned off.
(5) Drying time in hours
(6) Temperature in degrees Celsius
(7) Curve of insulation resistance during drying process
(8) Insulation resistance in megaohmsNote: When new insulation or damp insulation is being dried, the resistance will probably fall rapidly as the temperature is raised to a value for drying. After reaching a minimum for a given temperature, the resistance will again rise as moisture is driven out of the insulation. The actual values will vary with each situation. Refer to Illustration 3.If the windings or insulation become wet during the resistance measurement: Use a five megaohms resistor for protection, in series with the red positive lead, to limit the voltage across the circuit under test. Use this method until drying is well in progress, and the resistance has reached an acceptable level.During the drying period, check the windings every 4 hours, or every hour, for the method of circulating current with the insulation resistance tests. Refer to "Insulation Resistance Tests" for more information.Drying is complete when the testing demonstrates that PI > = 2. Record these readings in the Generator Test Data Sheet and compare to previous readings. Keep these records for future reference.External Heat
Ovens
The best oven is a forced air drying oven for drying electrical equipment. Radiant ovens sometimes cause localized overheating.
Do not heat the generator too quickly. Try to limit the rise in temperature of the insulation and windings to 11° C (19.8° F) per hour. Failure to
When water pressure is used for cleaning purposes, the pressure of the water must not exceed 205 kPa (30 psi) otherwise damage to the equipment may occur.
Flush the unit with fresh warm water in order to remove all traces of salt and silt. Washing should continue until tests of the fresh water show the insulation to be free of salt.Note: Complete disassembly of the generator may be necessary, in order to accomplish a proper cleaning.Bake and dry the unit completely with externally applied heat before placing back into service. Refer to the procedure in "Drying" for more information.Note: If the generator is used in or near salty air and high humidity environments, special electric component cleaners and protectors are needed to prevent corrosion.Drying
Drying may be accomplished by external heat, internal heat, a combination of internal heat and external heat, or circulating current.
When using external heat to dry the generator, do not exceed 85° C (185° F) otherwise damage to the equipment may occur.
External heat is the most preferable method. Insulation drying time can vary from a few hours to several days, depending on moisture content and the process used for drying.Note: Drying sometimes does not produce the required results. The use of a qualified rebuild shop for drying and redipping of the generator may be necessary.
Illustration 3 g01697133
Typical curves of the resistance in the insulation that is drying
(3) Curve of the temperature in the windings
(4) Heat turned off.
(5) Drying time in hours
(6) Temperature in degrees Celsius
(7) Curve of insulation resistance during drying process
(8) Insulation resistance in megaohmsNote: When new insulation or damp insulation is being dried, the resistance will probably fall rapidly as the temperature is raised to a value for drying. After reaching a minimum for a given temperature, the resistance will again rise as moisture is driven out of the insulation. The actual values will vary with each situation. Refer to Illustration 3.If the windings or insulation become wet during the resistance measurement: Use a five megaohms resistor for protection, in series with the red positive lead, to limit the voltage across the circuit under test. Use this method until drying is well in progress, and the resistance has reached an acceptable level.During the drying period, check the windings every 4 hours, or every hour, for the method of circulating current with the insulation resistance tests. Refer to "Insulation Resistance Tests" for more information.Drying is complete when the testing demonstrates that PI > = 2. Record these readings in the Generator Test Data Sheet and compare to previous readings. Keep these records for future reference.External Heat
Ovens
The best oven is a forced air drying oven for drying electrical equipment. Radiant ovens sometimes cause localized overheating.
Do not heat the generator too quickly. Try to limit the rise in temperature of the insulation and windings to 11° C (19.8° F) per hour. Failure to
Caterpillar SIS machinery equipment:
Caterpillar SIS
3508 GENERATOR SET ENGINE 23Z01023-03488 »
4W-5893
COOLER GP-ENGINE OIL
3508 Engine For Caterpillar Built Machines 97Y00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Engine For Caterpillar Built Machines 97Y00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Marine Engine 69Z00275-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Marine Engine 69Z00275-UP »
4W-5893
COOLER GP-ENGINE OIL
D11N TRACTOR / POWER SHIFT / 74Z00001-UP (MACHINE) POWERED BY 3508 ENGINE »
4W-5893
COOLER GP-ENGINE OIL
3508 Industrial Engine 68Z00694-01092 »
4W-5893
COOLER GP-ENGINE OIL
3508 Industrial Engine 68Z00694-01092 »
4W-5893
COOLER GP-ENGINE OIL
3508 GENERATOR SET ENGINE 1ZF00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 ENGINE 2JF00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 ENGINE 2JF00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 LOCOMOTIVE ENGINE 6TJ00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 LOCOMOTIVE ENGINE 6TJ00001-UP »
4W-5893
COOLER GP-ENGINE OIL
D11N Track-Type Tractor Power Shift 4HK00001-UP (MACHINE) POWERED BY 3508 Engine »
4W-5893
COOLER GP-ENGINE OIL
D11N Track-Type Tractor Power Shift 4HK00001-UP (MACHINE) POWERED BY 3508 Engine »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set Engine 70Z00757-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set Engine 70Z00757-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set Engine (High Speed) 23Z03489-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set Engine (High Speed) 23Z03489-UP »
4W-5893
COOLER GP-ENGINE OIL
5130 Excavator 5ZL00001-UP (MACHINE) POWERED BY 3508 Engine »
4W-5893
COOLER GP-ENGINE OIL
5130 Excavator 5ZL00001-UP (MACHINE) POWERED BY 3508 Engine »
4W-5893
COOLER GP-ENGINE OIL
G3508 Engine Electronic Ignition System 9TG00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 Engine Electronic Ignition System 9TG00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 Standard Engine Electronic Ignition System 4WD00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 Standard Engine Electronic Ignition System 4WD00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set Engine 6PN00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set Engine 6PN00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set Engine 4GM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set Engine 4GM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Engine 7SM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Engine 7SM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Engine 2BM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Engine 2BM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Auxiliary Engine 3DM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Auxiliary Engine 3DM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
D11R Track-Type Tractor Power Shift 8ZR00001-UP (MACHINE) POWERED BY 3508 Engine »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set Engine With EUI Option 5XM00001-00031 »
4W-5893
COOLER GP-ENGINE OIL
3508 Marine Engine With EUI Option 3PS00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Marine Auxiliary Engine With EUI Option 3TS00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set Engine With EUI Option 3LS00001-UP »
4W-5893
COOLER GP-ENGINE OIL
5130B Excavator 4CS00001-UP (MACHINE) POWERED BY 3508B Engine »
4W-5893
COOLER GP-ENGINE OIL
D11R Track-Type Tractor 9TR00001-UP (MACHINE) POWERED BY 3508 Engine »
4W-5893
COOLER GP-ENGINE OIL
D11R Carrydozer Track-Type Tractor 9XR00001-UP (MACHINE) POWERED BY 3508B Engine »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Auxiliary Engine 3DW00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Engine 1TW00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set Engine 2HW00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set 5KW00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set 5PW00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Locomotive Engine 5PS00001-UP »
4W-5893
COOLER GP-ENGINE OIL
D11R TRACK-TYPE TRACTOR 7PZ00001-UP (MACHINE) POWERED BY 3508B Engine »
4W-5893
COOLER GP-ENGINE OIL
G3508 Engine 2TJ00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Industrial Engine 95Y01065-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Industrial Engine 68Z01093-UP »
4W-5893
COOLER GP-ENGINE OIL
D11R Carrydozer Track-Type Tractor AAF00001-UP (MACHINE) POWERED BY 3508B Engine »
4W-5893
COOLER GP-ENGINE OIL
3508B Locomotive Engine 7AF00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Auxiliary Engine Military BAG00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Marine Generator Set Military 8TL00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Marine Generator Set Military 8TL00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Industrial Engine BPX00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Industrial Engine CBB00001-UP »
4W-5893
COOLER GP-ENGINE OIL
PM3508 Power Module BLM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
PM3508 Power Module BPY00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set CNB00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set CNF00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set BGX00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set CAW00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 Generator Set CPY00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 Generator Set CPJ00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 Generator Set CPS00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set Oil Field Land Rig PTK00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set Oil Field Land Rig PTN00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Marine Propulsion Engine Military 3HM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Generator Set Military LPD00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Auxiliary S2A00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Auxiliary Engine S2B00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Engine S2D00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Engine S2E00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Engine S2F00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Generator Set ZAB00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set ZAD00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 Engine DLR00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508C Engine LLC00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Engine Emissions Retrofit Repower Tier I For D11N Tractor 74Z00001-UP (MACHINE) »
4W-5893
COOLER GP-ENGINE OIL
3508C Industrial Engine LLE00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508C Marine Engine TTA00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508C Marine Engine TTB00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Locomotive Engine C8R00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 Engine WPM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508 Engine WPN00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 And 3508B Engine Emissions Repower Tier I For D11N Tractor 4HK00001-UP (MACHINE) »
4W-5893
COOLER GP-ENGINE OIL
3508C Locomotive Engine F1X00001-UP »
4W-5893
COOLER GP-ENGINE OIL
G3508B Gas Engine RBK00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508 Engine Performance Upgrade Group Retrofit From MUI to EUI Equivalent Level 96Y00694-01486 »
4W-5893
COOLER GP-ENGINE OIL
3508 Engine Emissions Upgrade Group Retrofit to Tier I Equivalent Level 96Y01487-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Engine Emissions Upgrade Group Retrofit From Tier I To Tier II Equivalent Level (Standard Stroke) 1TW00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Engine Emissions Upgrade Group Retrofit from EUI to Tier II Equivalent Level 7SM00001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Marine Auxiliary GS700001-UP »
4W-5893
COOLER GP-ENGINE OIL
3508B Generator Set Engine DPN00001-UP »
4W-5893
COOLER GP-ENGINE OIL
Cat SIS web machinery list:
Parts cooler Caterpillar catalog:
4N2388
COOLER GP-ENGINE OIL
24H, 3126, 3412, 3412C, 3412D, 3412E, 651E, 657E, 772B, 773B, 773D, 775B, 775D, 990, 990 II, 992C, 992D, C30, C32, CG137-12, D10N, D10R, D9L, G3412, G3412C, PM3412, PR-1000, PR-750B, SCT673, SPS342, S...
24H, 3126, 3412, 3412C, 3412D, 3412E, 651E, 657E, 772B, 773B, 773D, 775B, 775D, 990, 990 II, 992C, 992D, C30, C32, CG137-12, D10N, D10R, D9L, G3412, G3412C, PM3412, PR-1000, PR-750B, SCT673, SPS342, S...
1510258
COOLER GP-FUEL
3508, 3508B, 3512, 3512B, 3516, 3516B
3508, 3508B, 3512, 3512B, 3516, 3516B
5R8249
COOLER AR-JACKET WATER
3126, 3608
3126, 3608
5R8188
COOLER GP-FUEL
3126, 3608
3126, 3608
2642753
COOLER GP-FUEL
3508, 3512
3508, 3512
3327926
COOLER GP-ENGINE OIL
3508B, 3508C
3508B, 3508C
7E6633
COOLER-FUEL
3208, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, G3508, G3512, G3516, PM3412, PM3508
3208, 3412E, 3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B, 3516C, G3508, G3512, G3516, PM3412, PM3508
1721017
COOLER-FUEL
3508B, 3608
3508B, 3608
2471268
COOLER-FUEL
3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C
3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C
2642752
COOLER-FUEL
3508, 3508B, 3512, 3512B, 3516, 3516B
3508, 3508B, 3512, 3512B, 3516, 3516B
2013761
COOLER & MTG GP-HYDRAULIC OIL
322C, 325C
322C, 325C
7W1323
COOLER GP-FLTR BASE & ENG OIL
1673C, 3306, 3306B
1673C, 3306, 3306B
1157176
COOLER GP-HYDRAULIC OIL
515, 525
515, 525
2526849
COOLER GP-HYD & XMSN OIL
924G, 924GZ, 930G, IT28G
924G, 924GZ, 930G, IT28G
4N8268
COOLER GP-TRANSMISSION OIL
130G, 3306, 3306B, 637D, 639D
130G, 3306, 3306B, 637D, 639D
2P6215
COOLER GP-ENGINE OIL
120B, 120G, 12G, 130G, 140B, 140G, 14G, 215, 225, 235, 3304, 3306, 518, 528, 561D, 571G, 572G, 814, 814B, 815, 815B, 816, 816B, 920, 930, 930R, 950, 950B, 950B/950E, 951B, 955K, 955L, 963, 966C, 966D,...
120B, 120G, 12G, 130G, 140B, 140G, 14G, 215, 225, 235, 3304, 3306, 518, 528, 561D, 571G, 572G, 814, 814B, 815, 815B, 816, 816B, 920, 930, 930R, 950, 950B, 950B/950E, 951B, 955K, 955L, 963, 966C, 966D,...
3062319
COOLER GP-ENGINE OIL
420E, 430E, C4.4, CB-54, CB-64, CS-54B, M313D, M315D, M315D 2, M317D 2
420E, 430E, C4.4, CB-54, CB-64, CS-54B, M313D, M315D, M315D 2, M317D 2
1979405
COOLER GP-FLTR BASE & ENG OIL
416D, 424D
416D, 424D
2284336
COOLER GP-FUEL
3126B, C-9, C7, C9, CX31-C9I, TH31-E61
3126B, C-9, C7, C9, CX31-C9I, TH31-E61